To integrate an HPLC graph, identify peaks, set baseline, calculate area under peaks, and sum all peak areas.
Identify peaks by setting appropriate detection parameters.
Set baseline by adjusting baseline correction.
Calculate area under peaks using integration software.
Sum all peak areas to get total area under the curve.
HPLC columns are used in chromatography to separate and analyze compounds based on their interactions with the stationary phase.
There are different types of HPLC columns such as reverse-phase, normal-phase, ion-exchange, size-exclusion, and affinity columns.
Reverse-phase columns are the most commonly used and separate compounds based on hydrophobic interactions.
Normal-phase columns separate compounds based on polarity.
...
Hplc graph integration discussing
Top trending discussions
In group discussion, about my qualification, family and my current Job profile asked by the interview organizer.
posted on 2 Apr 2024
I applied via Company Website and was interviewed in Mar 2024. There was 1 interview round.
Normality refers to the state of being typical or usual, conforming to a standard or norm.
Normality is a concept used to describe the usual or expected state of something.
It can refer to the standard behavior, appearance, or function of a particular thing.
In quality control, normality is often used to determine if a product meets the expected standards.
For example, in a manufacturing process, normality would involve en...
The number of grams of solute dissolved in one liter of solution is known as the concentration of the solution.
This is known as the concentration of the solution
It is typically measured in grams per liter (g/L)
For example, if 10 grams of salt is dissolved in 1 liter of water, the concentration of the solution is 10 g/L
I applied via Company Website and was interviewed in Feb 2024. There was 1 interview round.
I applied via Referral and was interviewed in Mar 2023. There were 3 interview rounds.
I applied via Naukri.com and was interviewed before Apr 2023. There was 1 interview round.
Data integrity refers to the accuracy, consistency, and reliability of data throughout its lifecycle. ALCOA++ is a set of principles for ensuring data integrity.
ALCOA++ stands for Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, and Available.
Attributable - Data should be attributable to the person who created, modified, or observed it.
Legible - Data should be clear and easy t...
posted on 2 Mar 2024
I applied via Walk-in and was interviewed in Sep 2023. There was 1 interview round.
I applied via Referral and was interviewed before Dec 2023. There were 2 interview rounds.
Seeking new challenges and opportunities for growth.
Desire for career advancement
Seeking new challenges
Opportunity for professional growth
Change in job location or commute
Company restructuring or downsizing
I applied via Walk-in and was interviewed before Dec 2021. There were 3 interview rounds.
I have handled various instruments including calipers, micrometers, gauges, and spectrophotometers.
Calipers for measuring distance between two opposite sides of an object
Micrometers for measuring small distances with high precision
Gauges for measuring various parameters such as pressure, temperature, and humidity
Spectrophotometers for measuring the intensity of light in a spectrum
Also familiar with pH meters, balances,...
HPLC stands for High Performance Liquid Chromatography. It is a technique used to separate, identify, and quantify components in a mixture.
HPLC works on the principle of separation of components based on their interaction with the stationary phase and mobile phase.
The stationary phase is a solid or liquid material that is packed into a column, while the mobile phase is a liquid that flows through the column.
The sample ...
The stationary phase used in HPLC can be either polar or non-polar.
Polar stationary phases are used for separating polar compounds, while non-polar stationary phases are used for separating non-polar compounds.
Common polar stationary phases include silica gel and alumina, while common non-polar stationary phases include C18 and C8.
The choice of stationary phase depends on the properties of the sample being analyzed and...
I applied via Walk-in and was interviewed in Feb 2021. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 9 reviews
Rating in categories
Officer
358
salaries
| ₹2 L/yr - ₹6.5 L/yr |
Research Associate
336
salaries
| ₹3 L/yr - ₹6.5 L/yr |
Research Scientist
283
salaries
| ₹3.6 L/yr - ₹10.2 L/yr |
Senior Officer
274
salaries
| ₹3.3 L/yr - ₹8.1 L/yr |
Executive
269
salaries
| ₹3.7 L/yr - ₹11.1 L/yr |
Sun Pharmaceutical Industries
Cipla
DRJ & CO
Torrent Pharmaceuticals