I applied via Recruitment Consultant and was interviewed in Apr 2020. There were 4 interview rounds.
DC drive basic diagram consists of power supply, rectifier, chopper, and motor. VFD programming involves setting parameters for speed, torque, and acceleration.
DC drive diagram includes power supply, rectifier, chopper, and motor
VFD programming involves setting parameters for speed, torque, and acceleration
DC drive controls motor speed and direction
VFD can be programmed using software or keypad
VFD parameters can be adj
Asset metrics, ISO, Kaizen, and 5S are all important tools for improving efficiency and productivity in the workplace.
Asset metrics are measurements used to evaluate the performance of assets, such as equipment or machinery.
ISO (International Organization for Standardization) is a set of standards that provide guidelines for quality management systems.
Kaizen is a Japanese term that means continuous improvement. It invo...
ACBs and VCBs are circuit breakers used in substations. The type of relay used depends on the specific application.
ACBs (Air Circuit Breakers) and VCBs (Vacuum Circuit Breakers) are used in substations to protect electrical equipment from damage due to overloads or short circuits.
ACBs use air as the medium to extinguish the arc, while VCBs use vacuum.
The type of relay used depends on the specific application, such as o...
DC motor speed control parameters include armature voltage, field current, and mechanical load.
Armature voltage: controls the speed of the motor by varying the voltage applied to the armature.
Field current: controls the strength of the magnetic field and thus the speed of the motor.
Mechanical load: affects the speed of the motor by changing the amount of torque required to turn the motor.
Other factors include the type ...
Top trending discussions
I applied via Walk-in and was interviewed before May 2020. There was 1 interview round.
I applied via Company Website and was interviewed in Sep 2021. There were 2 interview rounds.
posted on 25 Dec 2023
I was interviewed in Jun 2023.
posted on 15 Sep 2023
I applied via Approached by Company and was interviewed in Mar 2023. There were 4 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
The repeated burning of a 22 kW AOP motor CT cable may be due to overloading, short circuits, poor insulation, or incorrect cable sizing.
Check for overloading of the motor causing excessive heat in the cable
Inspect for short circuits in the motor or the wiring
Ensure proper insulation of the cable to prevent overheating
Verify if the cable size is appropriate for the motor's power requirements
Bypassing the CT of an AOP motor can lead to overcurrent and damage to the motor.
Bypassing the CT can result in the motor drawing excessive current.
This can lead to overheating of the motor windings.
Overcurrent can cause damage to the motor components.
It can also pose a safety risk due to potential electrical faults.
posted on 7 Oct 2024
I applied via LinkedIn and was interviewed in Sep 2024. There was 1 interview round.
Synchronisation process of a plant involves matching the frequency, voltage, and phase angle of the incoming generator with the grid.
Ensure the generator frequency matches the grid frequency (50Hz or 60Hz).
Match the voltage levels of the generator with the grid.
Adjust the phase angle of the generator to synchronize with the grid.
Use synchronizing equipment like synchroscope or synchronizing lamps to ensure proper synch...
Alternator and transformer protection systems are essential for preventing damage and ensuring safe operation.
Alternator protection systems typically include overcurrent, overvoltage, and reverse power protection to safeguard the alternator from damage.
Transformer protection systems often involve differential protection, overcurrent protection, and temperature monitoring to prevent overheating and insulation breakdown.
...
posted on 28 Jan 2021
I applied via Recruitment Consultant and was interviewed in Dec 2020. There was 1 interview round.
This question is unclear and does not make sense.
Please provide more context or rephrase the question.
It is unclear what is being asked about gear boxes and valves.
Can you please provide more information or clarify the question?
I applied via Company Website and was interviewed before Apr 2020. There were 3 interview rounds.
Some of the top questions asked at the Maharashtra Seamless Electrical Shift Incharge interview -
Junior Engineer
131
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Engineer
99
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
81
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
68
salaries
| ₹0 L/yr - ₹0 L/yr |
Production Engineer
58
salaries
| ₹0 L/yr - ₹0 L/yr |
Jindal Saw
Welspun Corp
Man Industries
Surya Roshni