Filter interviews by
I applied via Approached by Company and was interviewed before Jun 2021. There were 3 interview rounds.
The specific power consumption of a plant depends on various factors such as the type of plant, its size, and the equipment used.
Specific power consumption is the amount of energy consumed per unit of production.
It can be calculated by dividing the total energy consumption by the total production output.
Factors that affect specific power consumption include the type of plant, its size, the equipment used, and the produ...
Top trending discussions
Implementation of new technologies
I applied via Referral and was interviewed in Dec 2023. There was 1 interview round.
posted on 23 Oct 2024
I applied via Approached by Company and was interviewed in Sep 2023. There were 2 interview rounds.
Currently working as a Senior Engineer in a software development company
Leading a team of engineers in developing and implementing software solutions
Providing technical guidance and support to team members
Collaborating with other departments to ensure project success
posted on 22 Jan 2023
I applied via Company Website and was interviewed in Dec 2022. There were 4 interview rounds.
Preventive maintenance is scheduled maintenance to prevent breakdowns while predictive maintenance uses data to predict failures.
Preventive maintenance involves regularly scheduled maintenance to prevent equipment breakdowns and prolong the lifespan of equipment.
Predictive maintenance uses data analysis to predict when equipment failure is likely to occur, allowing for maintenance to be scheduled before a breakdown occ...
PLC stands for Programmable Logic Controller and HMI stands for Human Machine Interface.
PLC is a digital computer used for automation of electromechanical processes.
It is used to control machinery on factory assembly lines, amusement rides, or light fixtures.
HMI is a graphical interface that allows humans to interact with machines.
It provides a visual representation of the process being controlled by the PLC.
Examples o...
Power factor can be managed by using capacitors, improving equipment efficiency, and reducing reactive power.
Install capacitors to offset reactive power and improve power factor
Upgrade equipment to more efficient models
Reduce the amount of reactive power by optimizing operations
Implement power factor correction techniques
Regularly monitor and maintain power factor levels
I applied via Approached by Company and was interviewed before Mar 2021. There was 1 interview round.
Implementation of new technologies
I applied via Referral and was interviewed in Dec 2023. There was 1 interview round.
Interview experience
based on 9 reviews
Rating in categories
Senior Engineer
220
salaries
| ₹3 L/yr - ₹8.3 L/yr |
Deputy Manager
105
salaries
| ₹4.2 L/yr - ₹10.2 L/yr |
Assistant Engineer
96
salaries
| ₹1.5 L/yr - ₹4.8 L/yr |
Engineer
62
salaries
| ₹2.4 L/yr - ₹6.5 L/yr |
Manager
31
salaries
| ₹6.7 L/yr - ₹16 L/yr |
Tata Steel
JSW Steel
Steel Authority Of India
Jindal Steel and Power