i
KEC International
Filter interviews by
I applied via Approached by Company and was interviewed in Mar 2022. There were 2 interview rounds.
Top trending discussions
posted on 10 Sep 2015
I applied via PLACEMENT
posted on 10 Sep 2017
I was interviewed before Sep 2016.
posted on 18 Nov 2020
Android architecture stack is a set of layers that make up the Android operating system.
The stack includes four main layers: Linux kernel, native libraries, Android runtime, and application framework.
The Linux kernel provides low-level system functionality.
Native libraries are written in C or C++ and provide access to hardware-specific features.
The Android runtime includes the Dalvik virtual machine and core libraries.
...
AIDL stands for Android Interface Definition Language, used for inter-process communication in Android.
AIDL is used to define the interface between client and service in Android.
It allows communication between different processes in Android.
AIDL is used to pass complex data types between processes.
AIDL is similar to Remote Procedure Call (RPC) in other programming languages.
Example: AIDL is used in Android to implement...
Hash set and hash map are data structures used to store key-value pairs for efficient retrieval.
Hash set stores unique values without any specific order.
Hash map stores key-value pairs and allows fast retrieval of values based on keys.
Both use hashing to map keys to their corresponding values.
In Java, HashSet and HashMap are implementations of these data structures.
posted on 12 May 2018
posted on 4 Nov 2021
I applied via Naukri.com and was interviewed in May 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed in Jan 2022. There were 2 interview rounds.
Basic aptitude from rs agrawal book is sufficient
I applied via Company Website and was interviewed in May 2023. There were 2 interview rounds.
Equipment used in steam turbine include turbine blades, nozzles, casing, rotor, bearings, and governor.
Turbine blades: convert steam energy into mechanical energy
Nozzles: control the flow of steam into the turbine
Casing: contains and directs the steam flow through the turbine
Rotor: connected to the turbine blades and rotates to generate power
Bearings: support the rotor and reduce friction
Governor: regulates the speed o
Woodward 505 is a versatile control system used in industrial applications.
The Woodward 505 is a widely used control system in industries such as power generation, oil and gas, and marine.
It offers advanced features like PID control, sequencing, and communication capabilities.
The Woodward 505 is known for its reliability and robustness in harsh operating environments.
It can be easily integrated with various types of se
The Honeywell DCS (Distributed Control System) is a modular system consisting of controllers, I/O modules, and operator stations.
Consists of controllers, I/O modules, and operator stations
Uses a network to communicate between components
Allows for centralized control and monitoring of processes
Supports various communication protocols such as Modbus, OPC, etc.
Example: Honeywell Experion PKS
PID stands for Proportional-Integral-Derivative, a control loop feedback mechanism used in engineering.
PID is a control algorithm that calculates an error value as the difference between a desired setpoint and a measured process variable.
Proportional (P) control responds to the current error value.
Integral (I) control accumulates past errors to correct the present error.
Derivative (D) control predicts future errors bas...
To assign a new channel in Honeywell DCS, you need to access the configuration software and follow the steps to add the channel.
Access the Honeywell DCS configuration software
Navigate to the channel configuration section
Add a new channel by specifying the channel number, type, and other relevant parameters
Save the changes and verify the new channel is successfully assigned
Interlocks and permissives are safety mechanisms in place to prevent unsafe operation of boiler and turbine systems.
Interlocks prevent certain actions from taking place unless specific conditions are met
Permissives allow certain actions to take place only if specific conditions are met
Example of interlock: Boiler feed pump interlock prevents the boiler from starting unless the feed pump is running
Example of permissive:...
posted on 26 Mar 2024
I applied via LinkedIn and was interviewed before Mar 2023. There were 2 interview rounds.
A water flow diagram of a Water Treatment Plant (WTP) shows the path of water through various treatment processes.
The diagram typically starts with raw water intake from a source such as a river or reservoir.
It then shows the water passing through processes like screening, coagulation, flocculation, sedimentation, filtration, and disinfection.
Finally, the treated water is stored in a clear well before distribution to c...
The capacity of structures in a Water Treatment Plant (WTP) is crucial for ensuring efficient operation and meeting demand.
Capacity of structures in a WTP refers to the maximum amount of water or waste that can be processed or stored.
Examples of structures in a WTP include sedimentation tanks, filters, pumps, and storage tanks.
Calculating the capacity involves considering factors like flow rates, retention times, and p...
based on 3 interviews
Interview experience
based on 16 reviews
Rating in categories
Assistant Manager
662
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
430
salaries
| ₹0 L/yr - ₹0 L/yr |
Civil Engineer
216
salaries
| ₹0 L/yr - ₹0 L/yr |
Project Engineer
212
salaries
| ₹0 L/yr - ₹0 L/yr |
Safety Officer
209
salaries
| ₹0 L/yr - ₹0 L/yr |
Larsen & Toubro Limited
Tata Projects
Sterlite Power
Kalpataru Projects International