i
JBS Enterprises
Filter interviews by
Manegement Topic of running our company
Current transformer secondary is open to prevent damage to the transformer and connected equipment.
An open secondary circuit prevents excessive current flow and protects the transformer from damage.
It allows for safe measurement and monitoring of current without risk of short circuits.
An open secondary also prevents damage to connected equipment by isolating it from high currents.
In case of a fault or overload, an open...
CT and PT are both electrical devices used in power systems, but they have different functions and applications.
CT stands for Current Transformer, while PT stands for Potential Transformer.
CTs are used to measure and transform high currents into manageable levels for instruments and protective relays.
PTs are used to measure and transform high voltages into low voltages for instruments and protective relays.
CTs are typi...
The single line diagram for HY to LT Panel diagram is a visual representation of the electrical connections and components in the system.
The single line diagram shows the flow of electrical power from the HY (High Voltage) side to the LT (Low Tension) side.
It includes the main components such as transformers, circuit breakers, switches, and control devices.
The diagram also indicates the interconnections between differe...
The number of circuit breakers used in an electrical system varies depending on the size and complexity of the system.
The number of circuit breakers used in an electrical system depends on factors such as the size of the system, the number of circuits, and the specific requirements of the building or facility.
Residential electrical systems typically have a main circuit breaker at the electrical panel, along with indivi...
In a power failure situation, effective management involves ensuring safety, communication, and contingency planning.
Ensure the safety of employees and customers by providing emergency lighting and clear evacuation procedures.
Maintain open lines of communication with staff, customers, and relevant authorities to provide updates and coordinate actions.
Implement contingency plans such as backup power sources, alternative...
B check in a generator refers to a comprehensive inspection and maintenance procedure to ensure its proper functioning.
B check involves a thorough examination of the generator's components, including the engine, fuel system, cooling system, electrical system, and control panel.
It includes tasks such as checking for leaks, inspecting belts and hoses, testing the battery, cleaning or replacing filters, and verifying prop...
Transformers require protection to prevent damage from faults, overloads, and external disturbances.
Overcurrent protection: Detects excessive current flow, triggering circuit breakers.
Differential protection: Compares input and output currents to identify faults.
Temperature monitoring: Uses sensors to prevent overheating, ensuring safe operation.
Bushing protection: Monitors insulation integrity to prevent failures.
Grou...
In a substation, I manage operations, ensure safety, and maintain equipment for efficient power distribution.
Monitor and control electrical equipment to ensure optimal performance.
Conduct regular inspections and maintenance of transformers and circuit breakers.
Implement safety protocols to protect personnel and equipment.
Coordinate with utility companies for power distribution and outages.
Respond to emergencies and tro
Circuit breakers (CB) protect electrical circuits from overloads and faults, ensuring safety and reliability.
Miniature Circuit Breaker (MCB): Automatically switches off during overloads, e.g., in residential wiring.
Molded Case Circuit Breaker (MCCB): Used for medium voltage applications, e.g., industrial machinery.
Earth Leakage Circuit Breaker (ELCB): Protects against earth faults, e.g., in wet areas like bathrooms.
Res...
Coordination with clients requires effective communication, understanding of their needs, and timely delivery of work.
Establish clear communication channels
Understand client's requirements and expectations
Provide regular updates on project progress
Address any concerns or issues promptly
Deliver work on time and within budget
Maintain a professional and respectful attitude
Build a positive and long-lasting relationship
JBS Enterprises interview questions for popular designations
Top trending discussions
posted on 10 Sep 2023
I applied via Walk-in and was interviewed in Mar 2023. There were 3 interview rounds.
Normal questions of logical and reasoning
posted on 6 Oct 2024
I applied via Approached by Company and was interviewed in Sep 2024. There were 2 interview rounds.
The test about the aptitude questions asked normally
Design of system and electrical grid network
At my last company, I faced challenges with outdated equipment and limited resources.
Outdated equipment made it difficult to efficiently complete tasks
Limited resources hindered the ability to innovate and improve processes
Lack of support from management in upgrading technology and tools
Difficulty in meeting project deadlines due to these challenges
I applied via Company Website and was interviewed in Sep 2023. There were 4 interview rounds.
General questions and department related questions will be asked
based on 2 interviews
Interview experience
based on 374 reviews
Rating in categories
Junior Engineer
126
salaries
| ₹1 L/yr - ₹3.8 L/yr |
Electrical Engineer
60
salaries
| ₹1.5 L/yr - ₹5 L/yr |
Shift Incharge
47
salaries
| ₹1.2 L/yr - ₹3.8 L/yr |
Shift Engineer
31
salaries
| ₹1.2 L/yr - ₹3.8 L/yr |
Engineer
30
salaries
| ₹1.5 L/yr - ₹3.8 L/yr |
Flex
MCM Telecom Equipment
Alfanar
Sgs Tekniks Manufacturing