I applied via Referral and was interviewed before Nov 2020. There was 1 interview round.
BMS system stands for Building Management System. It is a computer-based control system that monitors and manages various building functions.
BMS system is used to control and monitor HVAC (Heating, Ventilation, and Air Conditioning) systems in buildings.
It can also manage lighting, security, fire alarms, and other building systems.
BMS systems use sensors, controllers, and software to collect data and make adjustments t...
A BMS system is a centralized control system that monitors and manages various building systems.
BMS stands for Building Management System.
It integrates and controls various systems like HVAC, lighting, security, and fire safety.
It collects data from sensors and devices to monitor and optimize building performance.
BMS systems can automate processes, schedule maintenance, and provide real-time alerts.
Examples of BMS syst...
LMS stands for Load Management System in BMS which helps in managing the power consumption of the building.
LMS is a software-based system that monitors and controls the power consumption of a building.
It helps in optimizing the energy usage and reducing the energy costs.
LMS can be integrated with other systems in BMS such as HVAC, lighting, and security systems.
It can also provide real-time data on energy consumption a...
Top trending discussions
posted on 21 Apr 2023
I applied via Referral and was interviewed in Mar 2023. There were 2 interview rounds.
Yes, I am familiar with monitoring the normal temperature alarm input channel system.
I have experience in monitoring the temperature alarm input channel system in a BMS setup.
I am aware of the normal temperature range and the alarm thresholds that need to be set.
I can troubleshoot any issues related to the temperature monitoring system.
I can take corrective actions in case of any temperature alarms.
For example, in my p...
I applied via Naukri.com and was interviewed in Apr 2022. There were 2 interview rounds.
What is the responsibility you have to do and how to handle crucial situation.
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
It is a measure of how efficiently electrical power is being used.
It ranges from 0 to 1, with 1 being the most efficient.
A low power factor can result in higher energy costs and equipment damage.
Capacitors can be used to improve power factor.
Example: A motor with a power factor of 0.8 requires 1.25 times more current than a motor with a power fa
I applied via Recruitment Consulltant and was interviewed before Jun 2021. There was 1 interview round.
Specific power consumption is the amount of power consumed per unit of output.
It is a measure of energy efficiency.
It is calculated by dividing the power consumed by the output produced.
It is commonly used in industries to optimize energy usage.
Examples include kWh/ton in cement production and kWh/kg in textile manufacturing.
I appeared for an interview in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
I applied via Naukri.com and was interviewed in Oct 2021. There was 1 interview round.
I applied via Referral and was interviewed in Apr 2022. There were 3 interview rounds.
I applied via Approached by Company
based on 16 reviews
Rating in categories
Facility Executive
226
salaries
| ₹2 L/yr - ₹6 L/yr |
Assistant Manager
125
salaries
| ₹3.8 L/yr - ₹10.1 L/yr |
Assistant Facility Manager
107
salaries
| ₹3.3 L/yr - ₹8 L/yr |
Facility Manager
98
salaries
| ₹4.2 L/yr - ₹11.1 L/yr |
Technical Executive
80
salaries
| ₹3 L/yr - ₹5.2 L/yr |
Sodexo
Compass Group Support Services
BVG India
Leadec India