Filter interviews by
I was interviewed before May 2023.
Types of reactors include batch reactors, continuous stirred-tank reactors, and plug flow reactors.
Batch reactors operate in a closed system with a fixed amount of reactants.
Continuous stirred-tank reactors have continuous flow of reactants and products.
Plug flow reactors have a continuous flow with no mixing of reactants along the length of the reactor.
Distillation is a process used to separate components of a liquid mixture based on their boiling points.
Heat is applied to the mixture, causing the component with the lowest boiling point to vaporize first.
The vapor is then cooled and condensed back into liquid form, resulting in separate fractions.
This process is commonly used in the production of alcoholic beverages, petroleum refining, and water purification.
RTD sensor stands for Resistance Temperature Detector sensor. It is a type of temperature sensor that operates on the principle of the temperature dependence of electrical resistance of metals.
RTD sensors are commonly used in industrial applications for temperature measurement due to their high accuracy and stability.
They are often made of platinum, nickel, or copper and have a linear relationship between resistance an...
Flow meters are devices used to measure the flow rate of a fluid in a pipe or channel.
Differential pressure flow meters (e.g. Orifice plate, Venturi tube)
Velocity flow meters (e.g. Turbine, Electromagnetic)
Positive displacement flow meters (e.g. Piston, Gear)
Mass flow meters (e.g. Coriolis, Thermal)
Thermodynamics is the study of energy and its transformations. It involves laws like the first and second laws of thermodynamics.
Thermodynamics is the branch of physics that deals with the relationships between heat, work, and energy.
The first law of thermodynamics, also known as the law of energy conservation, states that energy cannot be created or destroyed, only transferred or transformed.
The second law of thermody...
Preventive maintenance is proactive maintenance performed to prevent equipment failure, while planned maintenance is scheduled maintenance to ensure optimal performance.
Preventive maintenance involves regularly inspecting, cleaning, and servicing equipment to prevent breakdowns and extend its lifespan.
Planned maintenance is scheduled in advance and includes tasks like replacing worn-out parts, lubricating machinery, an...
The refrigeration cycle is a thermodynamic process that removes heat from a space or substance to lower its temperature.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The compressor increases the pressure and temperature of the refrigerant gas.
The high-pressure gas then flows into the condenser where it releases heat and condenses into a high-pressure liquid.
The liqui...
I applied via Naukri.com and was interviewed before Jul 2022. There were 3 interview rounds.
Ipca Laboratories interview questions for designations
I applied via Referral and was interviewed before May 2020. There was 1 interview round.
A thermodynamics system refers to a region of space or a quantity of matter that is being studied in thermodynamics.
A system can be as simple as a single object or as complex as an entire universe.
It is separated from its surroundings by a boundary, which can be real or imaginary.
The system can exchange energy and matter with its surroundings through this boundary.
Thermodynamics systems are classified into open, closed...
Get interview-ready with Top Ipca Laboratories Interview Questions
Top trending discussions
I applied via Walk-in and was interviewed before Mar 2021. There were 2 interview rounds.
An HVAC flow diagram shows the path of air through a heating, ventilation, and air conditioning system.
The diagram typically includes components such as air handlers, ductwork, filters, and fans.
It shows the direction of airflow and the location of temperature and humidity sensors.
The diagram may also include information about the type of HVAC system, such as a split system or a packaged unit.
The flow diagram is import...
A water system flow diagram illustrates the movement of water through various components of a system.
The diagram typically includes sources of water, such as reservoirs or wells.
It shows the pathways through which water flows, such as pipes or channels.
Components like pumps, valves, and filters are depicted to indicate their role in the system.
The diagram may also include water treatment processes, such as filtration o...
QMS documentation procedure is a process of creating, maintaining, and updating documents related to quality management system.
Identify the documents required for QMS
Create and review the documents
Ensure the documents are accessible and controlled
Maintain and update the documents as necessary
Train employees on the QMS documentation procedure
I have handled various machines including printers, scanners, and copiers.
Printers: HP LaserJet, Canon Inkjet
Scanners: Epson, Fujitsu
Copiers: Xerox, Ricoh
I applied via Referral and was interviewed before Aug 2021. There were 2 interview rounds.
posted on 21 Jul 2020
I applied via Walk-in and was interviewed before Jul 2019. There were 4 interview rounds.
G.S.R.T.C apprenticeship Puri Thai gai che
posted on 5 Mar 2023
I applied via Walk-in and was interviewed in Jun 2022. There were 2 interview rounds.
Over binding can lead to restricted movement, discomfort, and potential damage to the bound area.
Restricted movement due to tight binding
Discomfort and pain from pressure on the bound area
Potential damage to blood circulation or nerves
Risk of tissue damage or skin irritation
Difficulty in breathing if binding is around the chest area
Inlet duct cleaning process involves removing dirt and debris from the duct to ensure proper airflow.
Inspect the duct for any visible dirt or debris
Use specialized tools such as brushes or vacuums to clean the duct
Ensure proper ventilation during the cleaning process
Regularly schedule duct cleaning to prevent buildup of dirt and debris
based on 7 interviews
Interview experience
based on 191 reviews
Rating in categories
Junior Officer
628
salaries
| ₹0 L/yr - ₹0 L/yr |
Officer
536
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Officer
444
salaries
| ₹0 L/yr - ₹0 L/yr |
Research Associate
239
salaries
| ₹0 L/yr - ₹0 L/yr |
Executive
230
salaries
| ₹0 L/yr - ₹0 L/yr |
Sun Pharmaceutical Industries
DRJ & CO
Cipla
Lupin