i
Insecticides India
Filter interviews by
I applied via Job Fair and was interviewed in Aug 2023. There was 1 interview round.
Top trending discussions
posted on 14 Dec 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 4 interview rounds.
I worked at XYZ Company, a manufacturing firm specializing in automotive components.
Responsible for conducting preventive maintenance on production machinery
Troubleshoot and repair mechanical issues on equipment
Collaborated with production team to ensure minimal downtime
Implemented new maintenance procedures to improve efficiency
Yes, I am willing to relocate or commute daily for the job.
I am open to relocating for the right opportunity.
I am willing to commute daily if necessary.
I understand the importance of flexibility in the job market.
I have handled a wide range of equipment in my role as a Mechanical Maintenance Engineer.
Pumps and compressors
Conveyors and material handling equipment
Boilers and heat exchangers
HVAC systems
Generators and power distribution systems
Machine tools and production equipment
Hydraulic and pneumatic systems
Crane and lifting equipment
Instrumentation and control systems
When opening a centrifugal pump, it is important to follow proper procedures to ensure safety and prevent damage.
Before opening the pump, ensure that it is isolated from the power source and all pressure has been relieved.
Inspect the pump for any signs of damage or wear, such as leaks, cracks, or excessive vibration.
Check the pump's impeller and casing for any debris or blockages that may affect its performance.
If nece...
Vacuum is created in a steam ejector through the principle of jet propulsion.
Steam ejectors use high-pressure steam to create a low-pressure environment.
The steam enters the nozzle of the ejector and expands, creating a high-velocity jet.
This high-velocity jet entrains and compresses the surrounding gas or vapor, reducing its pressure.
The entrained gas or vapor is then discharged through the diffuser, creating a vacuum...
1 torr is equal to 0.03937 mm of Hg.
1 torr is a unit of pressure equal to 1/760th of standard atmospheric pressure.
mm of Hg is a unit of pressure commonly used in vacuum systems.
To convert torr to mm of Hg, multiply by 0.03937.
Example: 1 torr = 1 * 0.03937 mm of Hg = 0.03937 mm of Hg.
759 mm of hg is a unit of pressure measurement.
mm of hg is a common unit used to measure pressure.
759 mm of hg is equivalent to 1012.8 millibars or 14.1 pounds per square inch (psi).
It is often used in meteorology to measure atmospheric pressure.
In mechanical maintenance, it can be used to monitor pressure in systems or equipment.
For example, if a pressure gauge reads 759 mm of hg, it indicates the pressure exerted by
In a clean room area, parameters observed include air quality, temperature, humidity, particle count, and pressure differentials.
Air quality is monitored to ensure low levels of contaminants.
Temperature is controlled to maintain a stable environment for sensitive equipment.
Humidity levels are regulated to prevent moisture-related issues.
Particle count is measured to ensure cleanliness and prevent contamination.
Pressure...
Mechanical seal types include cartridge seals, component seals, and bellows seals.
Cartridge seals are pre-assembled units that are easy to install and replace.
Component seals are made up of separate rotating and stationary parts.
Bellows seals use a flexible metal bellows to provide a dynamic seal.
posted on 10 Aug 2023
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
posted on 26 Jun 2023
I applied via Naukri.com and was interviewed before Jun 2022. There were 3 interview rounds.
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
Sorry, I cannot answer this question as it requires a visual aid to explain the wiring diagrams.
This question requires a visual aid to explain the wiring diagrams.
It is not possible to provide a written answer without a diagram.
Please refer to electrical engineering textbooks or online resources for detailed information.
posted on 13 Oct 2022
Various types of reactors are available for different purposes.
The most common types of reactors are batch, continuous stirred-tank, and plug flow reactors.
Other types include fluidized bed, fixed bed, and membrane reactors.
The choice of reactor depends on the specific chemical reaction and process conditions.
For example, a fluidized bed reactor may be used for catalytic cracking of petroleum, while a membrane reactor ...
posted on 8 Aug 2022
posted on 29 Apr 2022
I applied via Naukri.com and was interviewed in Oct 2021. There were 2 interview rounds.
Calculating cooling tower TR, boiler efficiency, and types and capacity of chilling plant compressors.
Cooling tower TR can be calculated using the formula: TR = (500 x GPM x Delta T)/12000
Boiler efficiency can be calculated using the formula: Efficiency = (Output/Input) x 100
Types of compressors include reciprocating, rotary screw, centrifugal, and scroll.
Capacity of compressors is measured in tons of refrigeration (TR...
Answering questions related to Maintenance Engineer interview.
Types of boilers include fire tube, water tube, and electric boilers.
Chilling plant capacity can be calculated by multiplying the flow rate by the temperature difference.
Colour coding in industry is used to identify pipes, wires, and equipment based on their function or contents.
Schedule maintenance is planned maintenance that is performed at regular interva...
posted on 6 Jan 2022
I applied via Recruitment Consultant
Installation of all types of drive parameters is a crucial aspect of maintenance electrician's job.
Maintenance electricians must have knowledge of all types of drive parameters and their installation procedures.
They should be able to read and interpret technical manuals and schematics.
They must ensure that the installation is done correctly and safely.
Examples of drive parameters include frequency converters, servo dri
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Plant Operator
134
salaries
| ₹1.5 L/yr - ₹4.4 L/yr |
Shift Incharge
28
salaries
| ₹3.1 L/yr - ₹7 L/yr |
QC Chemist
26
salaries
| ₹1.8 L/yr - ₹3.6 L/yr |
Chemist
20
salaries
| ₹2 L/yr - ₹3.5 L/yr |
Sales Officer
14
salaries
| ₹3 L/yr - ₹5.4 L/yr |
Bayer Crop Science Vegetable Seeds
UPL
Dhanuka Agritech
PI Industries