Filter interviews by
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
Sorry, I cannot answer this question as it requires a visual aid to explain the wiring diagrams.
This question requires a visual aid to explain the wiring diagrams.
It is not possible to provide a written answer without a diagram.
Please refer to electrical engineering textbooks or online resources for detailed information.
Top trending discussions
posted on 14 Dec 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 4 interview rounds.
I have handled a wide range of equipment in my role as a Mechanical Maintenance Engineer.
Pumps and compressors
Conveyors and material handling equipment
Boilers and heat exchangers
HVAC systems
Generators and power distribution systems
Machine tools and production equipment
Hydraulic and pneumatic systems
Crane and lifting equipment
Instrumentation and control systems
When opening a centrifugal pump, it is important to follow proper procedures to ensure safety and prevent damage.
Before opening the pump, ensure that it is isolated from the power source and all pressure has been relieved.
Inspect the pump for any signs of damage or wear, such as leaks, cracks, or excessive vibration.
Check the pump's impeller and casing for any debris or blockages that may affect its performance.
If nece...
Vacuum is created in a steam ejector through the principle of jet propulsion.
Steam ejectors use high-pressure steam to create a low-pressure environment.
The steam enters the nozzle of the ejector and expands, creating a high-velocity jet.
This high-velocity jet entrains and compresses the surrounding gas or vapor, reducing its pressure.
The entrained gas or vapor is then discharged through the diffuser, creating a vacuum...
1 torr is equal to 0.03937 mm of Hg.
1 torr is a unit of pressure equal to 1/760th of standard atmospheric pressure.
mm of Hg is a unit of pressure commonly used in vacuum systems.
To convert torr to mm of Hg, multiply by 0.03937.
Example: 1 torr = 1 * 0.03937 mm of Hg = 0.03937 mm of Hg.
759 mm of hg is a unit of pressure measurement.
mm of hg is a common unit used to measure pressure.
759 mm of hg is equivalent to 1012.8 millibars or 14.1 pounds per square inch (psi).
It is often used in meteorology to measure atmospheric pressure.
In mechanical maintenance, it can be used to monitor pressure in systems or equipment.
For example, if a pressure gauge reads 759 mm of hg, it indicates the pressure exerted by
In a clean room area, parameters observed include air quality, temperature, humidity, particle count, and pressure differentials.
Air quality is monitored to ensure low levels of contaminants.
Temperature is controlled to maintain a stable environment for sensitive equipment.
Humidity levels are regulated to prevent moisture-related issues.
Particle count is measured to ensure cleanliness and prevent contamination.
Pressure...
Mechanical seal types include cartridge seals, component seals, and bellows seals.
Cartridge seals are pre-assembled units that are easy to install and replace.
Component seals are made up of separate rotating and stationary parts.
Bellows seals use a flexible metal bellows to provide a dynamic seal.
posted on 2 Jan 2025
I applied via Approached by Company and was interviewed before Jan 2024. There were 4 interview rounds.
Single seals and double seals , Dri seals and Bellow seals
Reactors, ANFD, Centrifuge, centrifugal pumps, vacuum pumps , Millers and Avpf (Automatic vartical pressure filter)
Centrifuge problems can range from imbalance to motor issues, affecting sample separation and overall performance.
Check for proper balance of samples in the rotor
Inspect the motor for any signs of damage or malfunction
Ensure the centrifuge is on a level surface to prevent imbalance
Clean and maintain the centrifuge regularly to prevent buildup of debris
Consult the manufacturer's manual for troubleshooting tips
ANFD problems and maintenance involve troubleshooting and maintaining equipment used in the Agitated Thin Film Dryer process.
Regular inspection and cleaning of ANFD equipment to prevent buildup and clogging
Monitoring temperature and pressure levels to ensure optimal operation
Replacing worn out parts or components to prevent breakdowns
Calibrating sensors and instruments for accurate readings
Training staff on proper oper...
Excellent commitment co-operative & believe in team work.
Keeping organization goals a priority.
Competitive, efficient, Hardworking and Goal oriented
posted on 10 Aug 2023
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
posted on 26 Jun 2023
I applied via Naukri.com and was interviewed before Jun 2022. There were 3 interview rounds.
posted on 13 Oct 2022
Various types of reactors are available for different purposes.
The most common types of reactors are batch, continuous stirred-tank, and plug flow reactors.
Other types include fluidized bed, fixed bed, and membrane reactors.
The choice of reactor depends on the specific chemical reaction and process conditions.
For example, a fluidized bed reactor may be used for catalytic cracking of petroleum, while a membrane reactor ...
posted on 8 Aug 2022
I was interviewed before Dec 2022.
Machine design, SOM, Production, Thermodynamics fluid
posted on 6 Jan 2022
I applied via Recruitment Consultant
Installation of all types of drive parameters is a crucial aspect of maintenance electrician's job.
Maintenance electricians must have knowledge of all types of drive parameters and their installation procedures.
They should be able to read and interpret technical manuals and schematics.
They must ensure that the installation is done correctly and safely.
Examples of drive parameters include frequency converters, servo dri
posted on 7 Aug 2022
I applied via Job Portal and was interviewed in Jul 2022. There was 1 interview round.
based on 14 reviews
Rating in categories
Field Executive
524
salaries
| ₹2 L/yr - ₹6.3 L/yr |
Production Officer
483
salaries
| ₹1.5 L/yr - ₹7.8 L/yr |
Executive
226
salaries
| ₹3 L/yr - ₹11 L/yr |
Plant Operator
225
salaries
| ₹1.2 L/yr - ₹4.5 L/yr |
Executive Production
225
salaries
| ₹3 L/yr - ₹11.2 L/yr |
Bayer Crop Science Vegetable Seeds
Syngenta
Coromandel International
PI Industries