Add office photos
Engaged Employer

Ig3 Infra

3.7
based on 28 Reviews
Filter interviews by

Altruist Technologies Interview Questions and Answers

Updated 17 Jul 2024

Q1. If someone is bullying you at your work and you are not getting proper response what will you do and why? Remember that will never affect the project.

Ans.

If someone is bullying you at work and you are not getting a proper response, take the following steps:

  • Document the incidents of bullying, including dates, times, and details of each incident.

  • Report the bullying to your immediate supervisor or manager, providing them with the documented evidence.

  • If the bullying persists or your supervisor does not take appropriate action, escalate the issue to higher management or the HR department.

  • Seek support from colleagues or friends outs...read more

Add your answer

Q2. How will you overcome the issue if language barrier will affect your work? What if our project delayed due to this issue?

Ans.

I will address the language barrier by implementing effective communication strategies and seeking assistance when needed.

  • I will prioritize clear and concise communication with team members and stakeholders.

  • I will utilize visual aids, diagrams, and charts to enhance understanding.

  • I will encourage team members to ask questions and seek clarification.

  • I will establish a system for regular feedback and check-ins to ensure everyone is on the same page.

  • If necessary, I will seek ass...read more

Add your answer

Q3. Fire pump room and what type of motor, sprinkler system

Ans.

The fire pump room typically houses a fire pump with an electric motor and a sprinkler system for fire suppression.

  • Fire pump room contains a fire pump with an electric motor to provide water pressure for the sprinkler system

  • The sprinkler system is designed to automatically activate in case of a fire to suppress it

  • Regular maintenance and testing of the fire pump and sprinkler system are essential for proper functioning

Add your answer

Q4. Fire hydrant point's and fire extinguisher type and operating method

Ans.

Fire hydrant points are designated locations where firefighters can connect hoses to access water for firefighting. Fire extinguishers come in various types and have different operating methods.

  • Fire hydrant points are typically marked with a red and white 'H' symbol and are connected to a pressurized water supply.

  • Fire extinguishers can be of different types such as water, foam, CO2, dry chemical, and wet chemical.

  • Operating methods for fire extinguishers vary depending on the ...read more

Add your answer
Discover Altruist Technologies interview dos and don'ts from real experiences

Q5. Air cooled chiller working principle

Ans.

Air cooled chiller works by transferring heat from the process water to the ambient air through a refrigeration cycle.

  • Air cooled chiller uses a refrigerant to absorb heat from the process water and release it to the ambient air.

  • The refrigerant evaporates at low pressure and temperature in the evaporator coil, absorbing heat from the water.

  • The refrigerant then passes through a compressor where it is compressed and heated.

  • The hot, high-pressure refrigerant then flows through th...read more

Add your answer

Q6. What ia the ceiling used in toilet

Ans.

Ceilings in toilets are typically made of moisture-resistant materials like PVC, gypsum board, or metal.

  • Common materials used for toilet ceilings include PVC, gypsum board, and metal

  • Moisture-resistant properties are important to prevent damage from humidity and water exposure

  • Ceilings may also have ventilation systems to help reduce moisture buildup

  • Ceilings in commercial toilets may be made of more durable materials like stainless steel

Add your answer

Q7. AHU working principle

Ans.

AHU (Air Handling Unit) works by circulating and conditioning air within a building to maintain a comfortable environment.

  • AHU pulls in outside air through intake vents

  • Air passes through filters to remove dust and particles

  • Air is then heated or cooled by coils before being distributed through ducts

  • Return air is recirculated back into the AHU for reconditioning

  • AHU may also include humidifiers, dehumidifiers, and air purifiers for additional conditioning

Add your answer
Contribute & help others!
Write a review
Share interview
Contribute salary
Add office photos

Interview Process at Altruist Technologies

based on 4 interviews in the last 1 year
Interview experience
4.5
Good
View more
Interview Tips & Stories
Ace your next interview with expert advice and inspiring stories

Top Interview Questions from Similar Companies

3.7
 • 6.2k Interview Questions
3.7
 • 340 Interview Questions
3.9
 • 176 Interview Questions
3.6
 • 171 Interview Questions
3.9
 • 154 Interview Questions
4.2
 • 140 Interview Questions
View all
Top Ig3 Infra Interview Questions And Answers
Share an Interview
Stay ahead in your career. Get AmbitionBox app
qr-code
Helping over 1 Crore job seekers every month in choosing their right fit company
70 Lakh+

Reviews

5 Lakh+

Interviews

4 Crore+

Salaries

1 Cr+

Users/Month

Contribute to help millions
Get AmbitionBox app

Made with ❤️ in India. Trademarks belong to their respective owners. All rights reserved © 2024 Info Edge (India) Ltd.

Follow us
  • Youtube
  • Instagram
  • LinkedIn
  • Facebook
  • Twitter