Filter interviews by
I applied via Company Website and was interviewed in Dec 2023. There was 1 interview round.
Top trending discussions
Related to confidence
posted on 9 Aug 2023
I was interviewed in Feb 2023.
FAR stands for Floor Area Ratio, which is the ratio of a building's total floor area to the size of the piece of land on which it is built. Floor area refers to the total area of a floor in a building, carpet area is the area within the walls, and built-up area includes carpet area plus the thickness of walls.
FAR (Floor Area Ratio) is the ratio of a building's total floor area to the size of the land it is built on.
Flo...
I applied via Approached by Company and was interviewed before Jan 2023. There was 1 interview round.
posted on 6 Nov 2022
I applied via Company Website and was interviewed in Oct 2022. There were 2 interview rounds.
AutoCAD and Aviva are software used for designing.
AutoCAD is a computer-aided design software used for 2D and 3D design and drafting.
Aviva is a structural analysis and design software used for designing buildings and bridges.
Both softwares are widely used in the engineering and architecture industries.
AutoCAD can be used for designing anything from buildings to mechanical parts.
Aviva can be used for analyzing and desig...
posted on 15 Jul 2022
I applied via Job Portal
The number of days in RT varies depending on the job location.
The number of days in RT can range from a few days to several weeks.
The job location can be anywhere from a local facility to a remote site.
The duration of RT may also depend on the complexity of the job and the number of components to be inspected.
There are different types of RT (Radiographic Testing) techniques used in NDT.
RT techniques include film radiography, computed radiography, and digital radiography.
Each technique has its own advantages and disadvantages.
Film radiography is the oldest and most traditional method, while digital radiography is the newest and most advanced.
Computed radiography is a hybrid of film and digital radiography.
The choice of techn...
There are several types of PT materials used in non-destructive testing.
PT materials include water-washable, solvent-removable, and post-emulsifiable types.
Water-washable PT materials are commonly used for surface crack detection.
Solvent-removable PT materials are used for detecting cracks in non-porous materials.
Post-emulsifiable PT materials are used for detecting fine cracks and are often used in aerospace applicati
There are several types of NDT techniques used in various industries.
NDT stands for Non-Destructive Testing.
Some common types of NDT include ultrasonic testing, radiographic testing, magnetic particle testing, and liquid penetrant testing.
Each type of NDT has its own advantages and limitations, and is used for specific applications.
NDT is used in industries such as aerospace, automotive, construction, and manufacturing...
I applied via Referral and was interviewed in Oct 2022. There were 2 interview rounds.
Tests to be conducted before charging of Power transformer
Insulation resistance test
Polarity and phase-relation test
Turns ratio test
Vector group test
Oil test
Functional test
Scheduled maintenance programs for TSS and PSS
TSS (Total Suspended Solids) requires regular cleaning of filters and monitoring of chemical levels
PSS (Particulate Suspended Solids) requires regular cleaning of filters and monitoring of pressure levels
Both TSS and PSS require regular calibration of instruments and replacement of worn out parts
Maintenance schedules may vary depending on the specific equipment and usage
Reg...
Charging current of transmission line varies based on the conditions - OH or UG.
Charging current is the current that flows through the capacitance of the transmission line.
In OH conditions, the charging current is higher due to the larger distance between the conductors and the ground.
In UG conditions, the charging current is lower due to the smaller distance between the conductors and the ground.
The charging current a...
Use advanced earthing techniques and equipment to accurately measure earth values in rocky areas.
Use specialized equipment like clamp-on ground resistance testers
Install additional grounding rods to improve accuracy
Consider using chemical electrodes for better contact with the ground
Ensure proper installation and maintenance of earthing system
Consult with experts in earthing and grounding for best practices
The standard of railway crossings for different voltage lines as per RDSO.
RDSO specifies different standards for railway crossings based on the voltage of the lines.
For 33 kV lines, the minimum height of the overhead equipment is 5.5 meters.
For 11 kV lines, the minimum height of the overhead equipment is 5 meters.
For 132 kV lines, the minimum height of the overhead equipment is 7 meters.
For 440 kV lines, the minimum he...
Differential potential of transformer is the voltage difference between the primary and secondary windings.
It is a measure of the transformer's ability to isolate the primary and secondary circuits.
It is important for safety and proper functioning of the transformer.
The differential potential is affected by the turns ratio and the insulation between the windings.
A high differential potential can cause arcing and damage...
SOP of RE projects involves defining project scope, identifying stakeholders, creating project plan, executing and monitoring progress.
Define project scope and objectives
Identify stakeholders and their requirements
Create project plan with timelines and milestones
Execute project plan and monitor progress
Manage risks and issues
Ensure quality control and compliance
Close out project and conduct lessons learned
Implement strict inventory management, conduct regular audits, and train employees on theft prevention and material handling.
Implement a strict inventory management system to keep track of all materials and equipment.
Conduct regular audits to identify any discrepancies or missing items.
Train employees on theft prevention techniques and proper material handling procedures.
Install security cameras and alarms to deter the...
based on 1 interview
Interview experience
based on 61 reviews
Rating in categories
Senior Site Engineer
32
salaries
| ₹3.7 L/yr - ₹7 L/yr |
Senior Civil Site Engineer
11
salaries
| ₹3.6 L/yr - ₹7.5 L/yr |
Site Engineer
10
salaries
| ₹2.9 L/yr - ₹6 L/yr |
Project Engineer
7
salaries
| ₹5 L/yr - ₹11 L/yr |
HR Executive
7
salaries
| ₹2.5 L/yr - ₹7.4 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
Simplex Infrastructures