Filter interviews by
Top trending discussions
I appeared for an interview in Sep 2020.
I applied via Company Website and was interviewed in Oct 2020. There were 3 interview rounds.
I applied via Approached by Company and was interviewed in Aug 2022. There were 3 interview rounds.
Closed loop control systems are feedback systems that continuously monitor and adjust the output based on the desired input.
Closed loop control systems use feedback to maintain a desired output
They continuously monitor the output and compare it to the desired input
Based on the comparison, adjustments are made to maintain the desired output
Examples include thermostat-controlled heating systems and cruise control in cars
I applied via Referral and was interviewed in Feb 2021. There were 3 interview rounds.
I have 5 years of experience in retail management, overseeing teams and driving sales.
Managed a team of 15 sales associates and consistently exceeded sales targets
Implemented new training programs to improve customer service and product knowledge
Developed and executed marketing strategies to increase foot traffic and drive sales
Handled inventory management and ensured accurate stock levels
Resolved customer complaints a...
I applied via Approached by Company and was interviewed in Dec 2023. There were 2 interview rounds.
Channel sales refers to the process of selling products through third-party distributors or partners rather than directly to the end customers.
Involves using intermediaries such as wholesalers, retailers, or value-added resellers to reach customers
Allows companies to expand their reach and access new markets
Requires effective communication and collaboration with channel partners
Examples include selling software through...
Solar on grid system is a type of solar power system that is connected to the main electricity grid.
Solar panels generate electricity from sunlight
Excess electricity can be fed back into the grid
Reduces dependency on traditional power sources
Commonly used in residential and commercial buildings
posted on 24 Jul 2023
I applied via Approached by Company and was interviewed in Jun 2023. There were 3 interview rounds.
Testing of equipments involves ensuring they are functioning properly and meet safety standards.
Regularly inspect equipment for any signs of damage or wear
Conduct performance tests to ensure equipment is functioning as expected
Calibrate equipment regularly to maintain accuracy
Follow manufacturer's guidelines for testing and maintenance
Keep detailed records of testing and maintenance activities
Train staff on proper use ...
I appeared for an interview before Jan 2024.
Tests conducted on power transformers include insulation resistance test, turns ratio test, and power factor test.
Insulation resistance test checks the insulation of the transformer windings.
Turns ratio test verifies the turns ratio between primary and secondary windings.
Power factor test measures the efficiency of the transformer in converting power.
Other tests include winding resistance test, transformer oil testing,
Specifications for a 33 kV transmission line and how to select appropriate specifications
Specifications for a 33 kV transmission line include conductor size, insulation type, tower height, and distance between towers
Conductor size should be chosen based on current carrying capacity and voltage drop considerations
Insulation type should be selected based on environmental conditions and required insulation levels
Tower hei...
As an Assistant Manager, my job profile involves assisting the manager in overseeing daily operations, managing staff, and ensuring customer satisfaction.
Assist manager in daily operations
Manage staff and delegate tasks
Ensure customer satisfaction and handle customer complaints
Create work schedules and monitor employee performance
Relay coordination in electrical systems is the process of ensuring that protective relays operate in a coordinated manner to isolate faults while minimizing disruption to the system.
Relay coordination involves setting time-current curves for protective relays to ensure that the relay closest to the fault operates first.
It is important to coordinate relays to prevent unnecessary tripping of healthy equipment during a f...
based on 1 review
Rating in categories
Assistant Manager
422
salaries
| ₹2.5 L/yr - ₹10 L/yr |
Deputy Manager
271
salaries
| ₹4.1 L/yr - ₹14.5 L/yr |
Officer
235
salaries
| ₹2 L/yr - ₹7.2 L/yr |
Manager
85
salaries
| ₹6 L/yr - ₹20 L/yr |
Senior Manager
67
salaries
| ₹7.8 L/yr - ₹27 L/yr |
Adani Power
ReNew
Adani Green Energy
Vestas