i
Goodrich Logistics Pvt. Ltd.
Filter interviews by
I applied via Naukri.com and was interviewed in Oct 2023. There was 1 interview round.
I applied via Referral
Goodrich Logistics Pvt. Ltd. interview questions for popular designations
I applied via Approached by Company and was interviewed in Apr 2022. There were 3 interview rounds.
Based on process optimization
posted on 9 Mar 2024
I was interviewed before Mar 2023.
Financial Inclusion in India is improving but still faces challenges in reaching rural and marginalized populations.
Government initiatives like Jan Dhan Yojana have increased access to banking services
Digital payment systems like UPI have made transactions easier and more accessible
Challenges remain in reaching rural and marginalized populations due to lack of awareness and infrastructure
Microfinance institutions play ...
My expected CTC is negotiable based on the job role, responsibilities, and benefits offered.
My expected CTC is based on industry standards and my level of experience.
I am open to discussing the salary range during the interview process.
I am looking for a competitive salary package that aligns with my skills and qualifications.
posted on 16 Dec 2023
I applied via LinkedIn and was interviewed in Jun 2023. There were 2 interview rounds.
The hipot test can be done on a cable multiple times depending on the specific requirements and standards.
The number of times a hipot test can be done on a cable depends on the cable's specifications and the testing requirements.
Generally, a hipot test is performed once during the manufacturing process to ensure the cable's insulation integrity.
However, additional hipot tests may be conducted during the cable's lifespa...
If battery polarity is inverse with respect to battery charger, it can lead to damage or malfunction.
Inverse polarity can cause short circuits or overheating.
It can damage the battery, charger, or both.
Reverse polarity protection circuits can prevent damage.
Always double-check the polarity before connecting the battery to the charger.
There are several types of earthing used in electrical systems.
The most common types of earthing are:
- TN-S system: Separate neutral and protective earth conductors
- TN-C system: Combined neutral and protective earth conductors
- TN-C-S system: Combination of TN-S and TN-C systems
- TT system: Separate earth electrode for each electrical installation
- IT system: No direct connection between earth and neutral
Each type of ...
I have handled various quality documents such as quality control plans, inspection reports, and non-conformance reports.
Quality control plans
Inspection reports
Non-conformance reports
Tests done on power transformers include insulation resistance, turns ratio, winding resistance, and dielectric tests.
Insulation resistance test checks the insulation quality of the transformer.
Turns ratio test measures the ratio of primary to secondary turns.
Winding resistance test determines the resistance of transformer windings.
Dielectric tests assess the dielectric strength and insulation properties of the transfo...
Hipot testing is a process used to verify the insulation integrity of busbars, breakers, cables, and transformers.
Hipot testing involves applying a high voltage to the component being tested.
The purpose is to check for any insulation breakdown or leakage current.
For busbars and cables, the test is typically performed between the conductor and the ground.
For breakers and transformers, the test is performed between diffe...
IR, WR, and CR are abbreviations used in different contexts. IR stands for Infrared, WR stands for Weather Resistant, and CR stands for Compression Ratio.
IR refers to Infrared, which is a type of electromagnetic radiation with longer wavelengths than visible light.
WR is used to indicate that a product or material is designed to withstand various weather conditions.
CR is a term commonly used in engineering and physics t...
Tap changer in a transformer is located on the high voltage winding side to regulate the voltage output.
Tap changer is typically located on the high voltage winding side of a transformer.
It is used to adjust the turns ratio and regulate the voltage output.
If the voltage output in the secondary decreases, the tap changer will be moved to a higher tap position to increase the voltage.
I applied via Company Website and was interviewed in Mar 2022. There were 2 interview rounds.
Proove you are eligible for achive targate and focused to job.
I was interviewed before Mar 2022.
based on 2 interviews
Interview experience
based on 132 reviews
Rating in categories
Assistant Manager
45
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Executive
45
salaries
| ₹0 L/yr - ₹0 L/yr |
Customer Service Executive
26
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
25
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Customer Service Executive
19
salaries
| ₹0 L/yr - ₹0 L/yr |
Allcargo Logistics
Shreyas Shipping Logistics
Seaways Shipping Logistics