i
Goel Ganga Group
Filter interviews by
I applied via Naukri.com and was interviewed in Oct 2024. There were 2 interview rounds.
I applied via Company Website and was interviewed before Jul 2021. There were 3 interview rounds.
Top trending discussions
Section and elevation drawings of a bathroom
Include dimensions for all fixtures and fittings
Show the placement of plumbing lines and electrical outlets
Label materials and finishes for walls, floors, and fixtures
A leading engineering company specializing in innovative solutions for various industries.
Provides cutting-edge engineering solutions
Works with a wide range of industries such as automotive, aerospace, and technology
Focuses on research and development to stay ahead of the competition
Received positive feedback on technical skills and leadership abilities.
Received commendation for successfully leading a team in completing a major project ahead of schedule
Recognized for consistently providing innovative solutions to complex technical challenges
Received high ratings for communication skills and ability to collaborate effectively with cross-functional teams
I applied via Approached by Company and was interviewed in Aug 2024. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There were 2 interview rounds.
Density of common construction materials varies, with cement around 1440 kg/m3, steel around 7850 kg/m3, fine aggregate around 1600-1750 kg/m3, and coarse aggregate around 1200-1750 kg/m3.
Cement density: 1440 kg/m3
Steel density: 7850 kg/m3
Fine aggregate density: 1600-1750 kg/m3
Coarse aggregate density: 1200-1750 kg/m3
The weight of the cube used to check the strength of concrete is typically 15 cm x 15 cm x 15 cm and weighs around 29 kg.
Standard size of cube for testing concrete strength is 15 cm x 15 cm x 15 cm
Weight of the cube is usually around 29 kg
The cube is made of concrete from the same batch being tested
The ratio of cement mortar for outer and inner wall plastering varies depending on the type of wall and desired finish.
The ratio of cement mortar for outer wall plastering is usually 1:4 (1 part cement to 4 parts sand).
The ratio of cement mortar for inner wall plastering is typically 1:6 (1 part cement to 6 parts sand).
However, the ratio can vary based on factors such as the type of wall surface, desired finish, and lo...
My goal is to become a proficient Site Engineer by gaining experience, knowledge, and skills in the field.
Continuously seek opportunities to learn and improve technical skills
Work on various projects to gain practical experience
Seek mentorship from experienced engineers
Stay updated with industry trends and technologies
Obtain relevant certifications to enhance credibility
Set specific career milestones to track progress
I envision myself as a Senior Site Engineer leading projects and mentoring junior engineers.
Leading and managing multiple projects simultaneously
Mentoring and training junior engineers
Implementing innovative technologies and practices
Collaborating with cross-functional teams for successful project delivery
I applied via Walk-in
Internal plaster thickness and ratio are important factors in construction projects.
The standard thickness of internal plaster is usually 12mm for walls and 15mm for ceilings.
The ratio of internal plaster is typically 1:6 (1 part cement to 6 parts sand).
The thickness and ratio may vary depending on the specific requirements of the project and the type of surface being plastered.
Slab checking involves verifying the structural integrity and load-bearing capacity of concrete slabs.
Check for proper reinforcement placement and spacing
Verify concrete mix design and curing process
Inspect for any cracks or defects
Ensure slab thickness meets design specifications
Perform load testing if necessary
External plaster thickness and ratio are determined based on the type of surface and desired finish.
External plaster thickness typically ranges from 12mm to 20mm depending on the surface condition.
The ratio of external plaster mix is usually 1:4 (cement:sand) for rough surfaces and 1:6 for smooth finishes.
For better adhesion, a bonding agent may be added to the plaster mix.
Proper curing is essential to ensure the stren
I applied via Referral and was interviewed in Jan 2021. There were 5 interview rounds.
based on 3 interviews
Interview experience
based on 8 reviews
Rating in categories
Junior Engineer
36
salaries
| ₹2.2 L/yr - ₹4.3 L/yr |
Senior Engineer
31
salaries
| ₹3 L/yr - ₹9 L/yr |
Sales Executive
19
salaries
| ₹2 L/yr - ₹4 L/yr |
Sales Manager
14
salaries
| ₹2.8 L/yr - ₹6.5 L/yr |
Junior Engineer Civil
14
salaries
| ₹2.2 L/yr - ₹4.5 L/yr |
Realty Assistant
Kunal Structure
Omkar Realtors and Developers Group
HM Group