GD&T is a system of symbols and standards used to communicate engineering design and manufacturing requirements.
GD&T stands for Geometric Dimensioning and Tolerancing
It is used to define the allowable variation in form, size, orientation, and location of features on a part
It ensures that parts are manufactured to the correct specifications and fit together properly
GD&T symbols include straightness, flatness, circularit...
Top trending discussions
I applied via Company Website and was interviewed in May 2024. There were 2 interview rounds.
Communication between PLC controllers and DCS involves establishing a reliable connection for data exchange.
PLC controllers and DCS communicate through various communication protocols such as Modbus, Profibus, Ethernet/IP, etc.
Data is exchanged between PLC controllers and DCS for process control and monitoring.
Communication can be bidirectional, allowing both systems to send and receive data.
Proper configuration and pr...
I applied via LinkedIn and was interviewed in Mar 2024. There was 1 interview round.
posted on 20 Apr 2022
I applied via Walk-in and was interviewed before Apr 2021. There were 2 interview rounds.
Handling problems involves identifying the issue, analyzing it, developing a solution, and implementing it.
Identify the problem by gathering information and understanding the root cause.
Analyze the problem by breaking it down into smaller components and evaluating possible solutions.
Develop a solution by brainstorming ideas, considering constraints, and selecting the most effective approach.
Implement the solution by cr...
posted on 1 Feb 2021
I applied via campus placement at JNTU College of Engineering, Anantapur and was interviewed in Aug 2020. There was 1 interview round.
I applied via Naukri.com and was interviewed in Mar 2023. There were 2 interview rounds.
Environment conditions such as temperature, humidity, and cleanliness are crucial for panel installation.
Temperature should be within specified range to prevent damage to components.
Humidity levels should be controlled to avoid condensation and corrosion.
Cleanliness is important to prevent dust and debris from affecting performance.
Proper ventilation is necessary to prevent overheating.
Avoid exposure to direct sunlight...
Restricted Earth Fault is a type of fault in electrical systems where the fault current is limited to a specific section of the system.
Occurs when a fault current flows from a phase conductor to the earth through a restricted path
Usually detected by a relay that monitors the current imbalance between the phase and neutral conductors
Helps in quickly identifying and isolating the fault to prevent damage to equipment and ...
Differential earth fault is a type of fault in electrical systems where the current flowing into and out of the system is not equal due to an earth fault.
Differential earth fault protection is used to detect such faults by comparing the current entering and leaving the system.
It is important for safety as it helps prevent damage to equipment and potential electric shocks.
Examples of differential earth fault protection ...
Transformer insulation class indicates the temperature at which the insulation can operate safely.
Transformer insulation class is denoted by a letter (e.g. A, B, F, H) which corresponds to a maximum allowable temperature rise above ambient.
Higher insulation classes can withstand higher temperatures, providing better protection for the transformer.
Common insulation classes include A (105°C), B (130°C), F (155°C), and H
Implement a scheme using temperature sensors to detect transformer temperature.
Install temperature sensors at key points on the transformer
Set up a monitoring system to continuously track temperature readings
Establish temperature thresholds for alerts and shutdowns
Implement a cooling system to regulate temperature if needed
Voltage levels as per standards vary depending on the application and region, with common levels including 110V, 220V, and 415V.
Voltage levels can vary depending on the application and region
Common residential voltage levels include 110V and 220V
Industrial voltage levels are typically higher, such as 415V
International standards like IEC and ANSI provide guidelines for voltage levels
Molded Case Circuit Breakers (MCCBs) are types of circuit breakers that provide protection against overcurrents.
Thermal-magnetic MCCB: Trips when a current overload or short circuit is detected.
Electronic MCCB: Uses electronic components for more precise and adjustable protection.
Compact MCCB: Smaller in size for limited space installations.
Adjustable MCCB: Allows for manual adjustment of trip settings.
Motor protection...
Factors to consider for lighting calculation include type of space, desired lighting levels, fixture efficiency, and lighting layout.
Type of space (office, warehouse, retail, etc.)
Desired lighting levels (measured in lux or foot-candles)
Fixture efficiency (lumens per watt)
Lighting layout (spacing and placement of fixtures)
Natural lighting sources (windows, skylights)
Color rendering index (CRI) for accurate color repres...
I applied via LinkedIn and was interviewed in Mar 2022. There were 2 interview rounds.
A control valve is a device used to regulate the flow of a fluid in a system by varying the size of the flow passage.
Control valves are commonly used in industries such as oil and gas, chemical, and power plants.
They can be operated manually, pneumatically, electrically, or through a combination of these methods.
The operation of a control valve involves adjusting the position of the valve plug or disc to control the fl...
I applied via Recruitment Consultant and was interviewed in Apr 2021. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 10 reviews
Rating in categories
Service Engineer
218
salaries
| ₹3.8 L/yr - ₹11.8 L/yr |
Design Engineer
148
salaries
| ₹2.2 L/yr - ₹9.1 L/yr |
Senior Project Engineer
52
salaries
| ₹7.6 L/yr - ₹14 L/yr |
Senior Service Engineer
49
salaries
| ₹7.1 L/yr - ₹14.2 L/yr |
Technologist
43
salaries
| ₹2.4 L/yr - ₹5.3 L/yr |
Sandvik Mining and Rock Technology
Komatsu
Caterpillar Inc
Liebherr