I applied via Approached by Company and was interviewed in Mar 2023. There were 3 interview rounds.
Top trending discussions
I applied via Naukri.com and was interviewed in Mar 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Impedance is the total opposition to the flow of alternating current in a circuit, while reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Impedance is a combination of resistance and reactance in a circuit.
Reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Capacitive reactance is the opposition to the flow of alternating c...
Plant load factor is calculated by dividing the actual energy generated by the maximum possible energy that could have been generated.
Plant load factor = Actual energy generated / Maximum possible energy that could have been generated
Maximum possible energy is calculated by multiplying the rated capacity of the plant with the number of hours in a given time period
Plant load factor is expressed as a percentage
It is used...
I applied via Naukri.com and was interviewed before Jan 2022. There were 2 interview rounds.
Quality tools for analysis include Pareto charts, fishbone diagrams, scatter plots, and control charts.
Pareto charts help identify the most significant factors affecting quality
Fishbone diagrams help identify the root cause of a problem
Scatter plots help identify correlations between variables
Control charts help monitor and control a process over time
I have extensive experience working with various systems and machines in major projects.
Implemented ERP system for streamlining operations
Managed deployment of CRM system for customer relationship management
Led team in upgrading manufacturing machines for increased efficiency
Nothing much , rest is basically technical
We have to talk on a subject for log time thats all
Speed control on motors and generators can be achieved through various methods.
For motors, speed control can be achieved by adjusting the voltage, frequency, or the number of poles.
For generators, speed control can be achieved by adjusting the mechanical input or the load connected to the generator.
In motors, variable frequency drives (VFDs) can be used to control the speed by adjusting the frequency of the power suppl...
IDFT controller stands for Inverse Discrete Fourier Transform controller.
IDFT controller is used in signal processing to convert frequency domain signals to time domain signals.
It is the inverse of the Discrete Fourier Transform (DFT) controller.
IDFT controller is commonly used in audio and video processing applications.
It is also used in communication systems to convert frequency domain signals to time domain signals ...
posted on 29 Dec 2020
Dominant frequencies of 1×, 2×, and 3× RPM in the spectrum indicate faults in rotating equipment.
1× RPM indicates misalignment or unbalance
2× RPM indicates gear or bearing faults
3× RPM indicates resonance or coupling issues
Diagnosing abnormal sound from mill motor without vibration analyzer
Check for any visible signs of damage or wear on the motor and surrounding components
Listen for any changes in the sound when the motor is turned off and on again
Check the lubrication system and oil levels
Inspect the belts and pulleys for any signs of wear or damage
Consult with experts or manufacturers for further guidance
Centrifugal pump performance characteristics refer to the relationship between flow rate, head, power, and efficiency.
Flow rate is the volume of fluid that passes through the pump per unit time.
Head is the energy added to the fluid by the pump and is proportional to the pressure increase.
Power is the energy required to operate the pump and is proportional to the flow rate and head.
Efficiency is the ratio of the energy ...
HP and KW are units of power measurement, with HP being the imperial unit and KW being the metric unit.
HP stands for horsepower and is commonly used in the United States and other countries that use the imperial system of measurement.
KW stands for kilowatt and is commonly used in countries that use the metric system of measurement.
1 horsepower is equal to 0.7457 kilowatts.
The relationship between HP and KW is important...
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
based on 1 interview
Interview experience
Deputy Manager
222
salaries
| ₹5 L/yr - ₹17.5 L/yr |
Manager
161
salaries
| ₹5.8 L/yr - ₹24.1 L/yr |
Senior Engineer
159
salaries
| ₹4 L/yr - ₹12 L/yr |
Engineer
87
salaries
| ₹3 L/yr - ₹8.4 L/yr |
Senior Manager
63
salaries
| ₹10 L/yr - ₹32 L/yr |
Vestas
Dhoot Transmission
Hitachi Energy
Siemens Energy