Filter interviews by
I applied via Walk-in and was interviewed in May 2024. There were 2 interview rounds.
Ginen sample parts for sketching and drawing in autocad
The formula for calculating the dimensions of spur gears is based on the module, number of teeth, and pitch diameter.
Formula for calculating the pitch diameter: PD = Module x Number of Teeth
Formula for calculating the outside diameter: OD = (Number of Teeth + 2) x Module
Formula for calculating the addendum: Addendum = Module
Formula for calculating the dedendum: Dedendum = 1.25 x Module
Formula for calculating the cleara
I applied via Approached by Company and was interviewed in Mar 2024. There was 1 interview round.
I applied via Company Website and was interviewed in Mar 2022. There was 1 interview round.
I applied via Naukri.com and was interviewed in Jun 2020. There were 4 interview rounds.
The interview questions cover topics related to DC motors, speed control, transformers, and circuit breakers.
DC motors convert electrical energy into mechanical energy
Speed of DC motor can be controlled by varying the armature voltage or field current
Transformers are of two types - step-up and step-down
Vacuum circuit breakers use vacuum as the arc quenching medium while air circuit breakers use air
Rectifier converts AC to DC. IGBT testing involves checking its switching characteristics.
Rectifier is an electronic device that converts AC to DC.
IGBT (Insulated Gate Bipolar Transistor) is a power semiconductor device used for switching applications.
IGBT testing involves checking its switching characteristics such as turn-on and turn-off times, voltage and current ratings, and thermal performance.
Testing can be done ...
D.P.Jindal Group interview questions for popular designations
Top trending discussions
posted on 15 Jan 2025
I applied via AmbitionBox and was interviewed in Dec 2024. There were 5 interview rounds.
An overload relay works by monitoring the current flowing through a motor and tripping when the current exceeds a set limit.
Monitors the current flowing through a motor
Trips and interrupts power when current exceeds a set limit
Protects the motor from damage due to overloading
Can be reset manually after tripping
Insulation resistance is measured using a megohmmeter to apply a high voltage and measure the resistance of the insulation material.
Use a megohmmeter to apply a high voltage to the insulation material
Measure the resistance of the insulation material to determine its insulation resistance
Insulation resistance is typically measured in megaohms (MΩ)
Regular insulation resistance testing helps prevent electrical failures an
Electrical safety can be ensured by following proper procedures, using appropriate equipment, and staying vigilant.
Always use insulated tools when working on live circuits
Ensure circuits are de-energized before working on them
Wear appropriate personal protective equipment (PPE) such as gloves and goggles
Regularly inspect and maintain electrical equipment to prevent malfunctions
Follow safety guidelines and procedures ou
Preventive maintenance on a motor involves inspecting, cleaning, lubricating, and testing the motor to ensure optimal performance and prevent breakdowns.
Inspect the motor for any signs of wear or damage
Clean the motor and its components to remove dirt and debris
Lubricate moving parts to reduce friction and wear
Test the motor's performance using appropriate tools and equipment
Replace any worn out parts or components as
To succeed in an interview, it is important to prepare thoroughly, practice common interview questions, research the company, dress professionally, and demonstrate enthusiasm and confidence.
Thoroughly research the company and the position you are applying for
Practice common interview questions and prepare examples of your skills and experiences
Dress professionally and appropriately for the interview
Demonstrate enthusia...
A star-delta starter is used to reduce the starting current of a motor by initially connecting the motor windings in a star configuration and then switching to a delta configuration.
The motor windings are initially connected in a star configuration during starting to reduce the starting current.
After a certain period, the windings are switched to a delta configuration to achieve full speed and torque.
This transition fr...
Undervoltage faults occur when the voltage in a system drops below the normal operating level, leading to potential equipment damage or malfunction.
Undervoltage faults can be caused by issues such as power supply fluctuations, equipment failures, or overloaded circuits.
These faults can lead to equipment damage, reduced efficiency, or complete shutdown of systems.
Examples include a power surge causing a drop in voltage,...
Overvoltage faults are electrical faults that occur when the voltage in a circuit exceeds the normal operating range.
Overvoltage faults can damage electrical components and equipment.
They can be caused by lightning strikes, power surges, or faulty equipment.
Protective devices like surge protectors and voltage regulators can help prevent overvoltage faults.
Examples include a power surge from a lightning strike damaging ...
A thermal relay is used to protect electrical circuits from overloads by monitoring the temperature of the circuit and tripping when it exceeds a certain threshold.
Monitors the temperature of the electrical circuit
Trips and disconnects the circuit when temperature exceeds a set limit
Protects against overloads and overheating
Commonly used in motor protection applications
An RDOL starter is a type of reduced voltage starter used in electrical systems to reduce the starting current and torque of a motor.
RDOL stands for Reduced Direct Online starter.
It is used to start induction motors in a controlled manner.
RDOL starters reduce the voltage supplied to the motor during starting to limit the inrush current.
This helps in reducing mechanical stress on the motor and connected equipment.
Common...
posted on 17 Feb 2025
posted on 22 Jan 2025
I was interviewed in Dec 2024.
posted on 6 Feb 2025
I was interviewed in Jan 2025.
Modes of heat transfer include conduction, convection, and radiation.
Conduction: Heat transfer through direct contact between particles. Example: Touching a hot pan.
Convection: Heat transfer through the movement of fluids (liquids or gases). Example: Boiling water.
Radiation: Heat transfer through electromagnetic waves. Example: Feeling the warmth of the sun.
An addendum circle is a circle that is tangent to two other circles and intersects them at their points of tangency.
Addendum circle is commonly used in gear design to determine the correct size of gears.
It is tangent to two other circles, known as the base circles, and intersects them at their points of tangency.
The addendum circle is larger in diameter than the base circles, allowing for the teeth of the gears to mesh
Rankine cycle is a thermodynamic cycle used in steam power plants to generate electricity.
Rankine cycle involves four processes: compression, heating, expansion, and cooling.
Steam is compressed in a pump, heated in a boiler to high temperature and pressure, expanded in a turbine, and then cooled in a condenser.
The cycle is used in steam power plants to convert thermal energy into mechanical work, which is then used to
based on 5 interviews
Interview experience
based on 66 reviews
Rating in categories
Assistant Engineer
20
salaries
| ₹2.6 L/yr - ₹4.7 L/yr |
Junior Engineer
12
salaries
| ₹2 L/yr - ₹4 L/yr |
Senior Accounts Executive
7
salaries
| ₹5.7 L/yr - ₹7.8 L/yr |
Company Secretary
7
salaries
| ₹4.4 L/yr - ₹5.9 L/yr |
Executive
7
salaries
| ₹4.1 L/yr - ₹5.2 L/yr |
Tata Group
Aditya Birla Group
Reliance Industries
Mahindra & Mahindra