Filter interviews by
As a Safety Officer, I am trained to identify hazards in confined spaces like toxic and flammable gases.
I have extensive knowledge of the different types of toxic and flammable gases that can be present in confined spaces.
I am familiar with the methods and equipment used to detect and measure gas concentrations, such as gas detectors and sampling techniques.
I understand the concept of Lower Explosive Limit (LEL), which...
ELCB is used for electrical safety by detecting and interrupting abnormal current flow. The mA used for shock protection varies.
ELCB stands for Earth Leakage Circuit Breaker.
It is used to protect against electric shock and fire hazards caused by faulty electrical equipment or wiring.
ELCB detects the leakage current flowing to the earth and interrupts the circuit to prevent electric shock.
The amount of mA used for shock...
I applied via Referral
I applied via Company Website and was interviewed in Mar 2023. There were 3 interview rounds.
Cochin Shipyard interview questions for popular designations
I applied via Company Website and was interviewed before Jan 2023. There were 2 interview rounds.
I applied via Company Website
I applied via Campus Placement and was interviewed before Jun 2021. There were 2 interview rounds.
I'm sorry, but the question is unclear and seems to be incomplete.
The question lacks context and details.
It is unclear what is being asked.
Please provide more information or rephrase the question.
Without additional information, it is impossible to answer the question.
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Acetylene cylinders are kept in an upright position to prevent the acetone inside from leaking.
Keeping acetylene cylinders upright prevents the acetone from coming into contact with the porous material inside the cylinder.
Acetone is used as a solvent to stabilize acetylene gas, and it is stored in a porous material to prevent the gas from becoming unstable.
If the cylinder is not kept upright, the acetone can leak out, ...
Stand 6-8 feet away from the fire when using a fire extinguisher.
Maintain a safe distance of 6-8 feet from the fire.
Position yourself with an escape route behind you.
Aim the extinguisher at the base of the fire.
Sweep the extinguisher from side to side until the fire is out.
I applied via Company Website and was interviewed in Oct 2020. There were 5 interview rounds.
Top trending discussions
Some of the top questions asked at the Cochin Shipyard interview -
based on 7 interviews
Interview experience
based on 225 reviews
Rating in categories
Project Officer
89
salaries
| ₹3.5 L/yr - ₹6 L/yr |
Supervisor
31
salaries
| ₹0.7 L/yr - ₹8 L/yr |
Project Assistant
30
salaries
| ₹2.5 L/yr - ₹4 L/yr |
Safety Officer
22
salaries
| ₹2.2 L/yr - ₹5.5 L/yr |
Deputy Manager
17
salaries
| ₹10.5 L/yr - ₹18 L/yr |
Garden Reach Shipbuilders & Engineers
Mazagon Dock
Bharati Defence and Infrastructure
ABG Shipyard