Centaur Pharmaceuticals
10+ Artisan Media Solutions Interview Questions and Answers
Q1. Can u work 16hrs if any load time or it may extend to 24hrs
Yes, I am willing to work extended hours if required.
I am committed to meeting deadlines and completing tasks on time.
I am willing to work overtime if necessary to ensure the job is done right.
I understand that sometimes workloads can be unpredictable and I am prepared to adapt to changing circumstances.
I have experience working long hours in high-pressure environments, such as during peak season in retail.
I am confident in my ability to manage my time effectively and priorit...read more
Q2. how to work under high pressure
To work under high pressure, I prioritize tasks, stay organized, and maintain a positive attitude.
Prioritize tasks based on urgency and importance
Stay organized by creating to-do lists and breaking down tasks into smaller steps
Maintain a positive attitude by taking breaks, practicing self-care, and seeking support from colleagues
Communicate effectively with team members and superiors to ensure everyone is on the same page
Stay focused on the end goal and remind myself of the i...read more
Q3. What Marketing you have learnt in 3 months time period
I have learned the importance of target audience, market research, and creating a strong brand image.
Identifying target audience through demographics and psychographics
Conducting market research to understand consumer behavior and preferences
Creating a strong brand image through consistent messaging and visual identity
Utilizing various marketing channels such as social media, email marketing, and content marketing
Measuring and analyzing marketing metrics to optimize campaigns
Q4. What is SFM .What is cfm .Data Integrity . What is ALCOA .RMG problem .FBD and types of Filter. AHU .RMG and FBD all parts Name . SFM testing All prosses .And What is Granulation. And one product all top to Bot...
read moreA series of questions related to pharmaceutical manufacturing processes and regulations.
SFM stands for Standard Flow Method and is used to measure the flow rate of gases.
CFM stands for Cubic Feet per Minute and is used to measure the flow rate of air.
Data Integrity refers to the accuracy and consistency of data throughout its lifecycle.
ALCOA stands for Attributable, Legible, Contemporaneous, Original, and Accurate, which are principles for ensuring data integrity.
RMG problem ...read more
Q5. What is difference between Marketing and Strategy?
Marketing is the process of promoting and selling products or services, while strategy is the plan of action to achieve business goals.
Marketing focuses on the customer and their needs, while strategy focuses on the company's goals and objectives.
Marketing is more tactical and short-term, while strategy is more long-term and holistic.
Marketing involves creating and executing campaigns to reach target audiences, while strategy involves analyzing market trends and competition t...read more
Q6. What is the flow of brand plan?
Brand plan flow involves market research, target audience identification, setting objectives, developing strategies, implementing tactics, and measuring results.
Conduct market research to identify target audience and their needs
Set objectives and goals for the brand plan
Develop strategies to achieve the objectives
Implement tactics such as advertising, promotions, and events
Measure the results and adjust the plan accordingly
Q7. What is Marketing according to you?
Marketing is the process of creating, communicating, delivering, and exchanging offerings that have value for customers, clients, partners, and society at large.
Marketing involves identifying customer needs and wants
It includes creating and promoting products or services
It involves pricing and distributing products or services
Marketing also involves building and maintaining relationships with customers
Examples include advertising, public relations, and market research
Q8. Ok full form
The question is asking for the full form of an abbreviation or acronym.
Provide the complete expansion of the abbreviation or acronym
Use correct grammar and punctuation
If unsure, ask for clarification or provide multiple possibilities
Q9. What is sterilization and types
Sterilization is the process of killing all microorganisms, including bacteria, viruses, and spores, to prevent contamination.
Sterilization methods include heat (autoclaving), radiation (UV, gamma), filtration, chemical (ethylene oxide), and dry heat.
Autoclaving is a common method where steam under pressure is used to kill microorganisms.
UV radiation is used for surface sterilization in laboratories.
Ethylene oxide gas is used for sterilizing heat-sensitive medical devices.
Fil...read more
Q10. What is gram staining
Gram staining is a technique used to differentiate bacteria into two groups based on their cell wall composition.
Involves staining bacterial cells with crystal violet dye, iodine, alcohol wash, and safranin counterstain
Gram-positive bacteria retain the purple color, while gram-negative bacteria appear pink/red
Helps in identifying bacterial species and determining appropriate treatment
Developed by Hans Christian Gram in 1884
Q11. What is function of laminar
Laminar flow hoods are used to create a sterile work environment by directing air flow in a controlled manner.
Laminar flow hoods are used in microbiology labs to prevent contamination of samples and cultures.
They work by filtering air through a HEPA filter and directing it in a unidirectional flow over the work area.
Laminar flow hoods are essential for maintaining aseptic conditions during experiments and testing.
They are commonly used in pharmaceutical, biotechnology, and cl...read more
Q12. Validation strategy for ANDA submissions.
The validation strategy for ANDA submissions involves ensuring the accuracy and reliability of data and documentation.
Develop a comprehensive validation plan that outlines the objectives, scope, and approach for the ANDA submission.
Perform validation activities such as analytical method validation, process validation, and cleaning validation.
Ensure compliance with regulatory guidelines and requirements, such as FDA's Guidance for Industry on ANDA Submissions.
Conduct thorough ...read more
Q13. Function of spectrophotometer
A spectrophotometer is a scientific instrument used to measure the intensity of light at different wavelengths in a sample.
Measures the absorbance or transmittance of light by a sample
Used to quantify the concentration of a substance in a sample
Can be used for DNA quantification in molecular biology
Helps in determining the purity of a compound
Q14. pH meter uses and definition
pH meter is a device used to measure the acidity or alkalinity of a substance.
pH meter measures the hydrogen ion concentration in a solution.
It is commonly used in laboratories to test the pH of various substances such as water, food, and pharmaceuticals.
The pH scale ranges from 0 (very acidic) to 14 (very alkaline), with 7 being neutral.
Regular calibration and maintenance of pH meters are essential for accurate results.
Top HR Questions asked in Artisan Media Solutions
Interview Process at Artisan Media Solutions
Top Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month