A spectrophotometer is a scientific instrument used to measure the intensity of light at different wavelengths in a sample.
Measures the absorbance or transmittance of light by a sample
Used to quantify the concentration of a substance in a sample
Can be used for DNA quantification in molecular biology
Helps in determining the purity of a compound
pH meter is a device used to measure the acidity or alkalinity of a substance.
pH meter measures the hydrogen ion concentration in a solution.
It is commonly used in laboratories to test the pH of various substances such as water, food, and pharmaceuticals.
The pH scale ranges from 0 (very acidic) to 14 (very alkaline), with 7 being neutral.
Regular calibration and maintenance of pH meters are essential for accurate result
I applied via Referral and was interviewed before Oct 2022. There were 3 interview rounds.
Microbiology, sterilization, culture techniques, disinfectant preparation, history, grams staining.
Validation ensures that the system meets the user's needs, while qualification ensures that the system is installed and operates correctly.
Validation confirms that the system meets the user's requirements and expectations.
Qualification ensures that the system is installed correctly and operates within predefined specifications.
Validation is more focused on user needs and expectations, while qualification is more focuse...
GLP stands for Good Laboratory Practice, which ensures the reliability and integrity of data generated in a laboratory setting.
GLP is a set of guidelines for conducting non-clinical safety studies on chemicals, pharmaceuticals, and other products.
It includes requirements for the organization, personnel, facilities, equipment, and documentation of studies.
Data integrity refers to the accuracy, completeness, and reliabil...
HPLC and GC are analytical techniques used in chemistry to separate and analyze compounds in a mixture.
HPLC stands for High Performance Liquid Chromatography, which uses a liquid mobile phase to separate compounds based on their interactions with a stationary phase.
GC stands for Gas Chromatography, which uses a gas mobile phase to separate compounds based on their volatility and interactions with a stationary phase.
Bot...
I applied via Walk-in and was interviewed in Sep 2021. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Aug 2023. There were 2 interview rounds.
UV, IR, KF, and polarimeter are analytical instruments used for different types of analysis based on principles of light absorption, emission, and rotation.
UV (Ultraviolet) spectrophotometer measures the absorption of ultraviolet light by a sample to determine its concentration or purity.
IR (Infrared) spectrophotometer measures the absorption of infrared light by a sample to identify functional groups in organic compou...
Calibration of analytical balance is essential for accurate measurements in analytical chemistry.
Calibration involves comparing the readings of the balance to known weights.
Regular calibration ensures accuracy and reliability of measurements.
Adjustments may be needed if the balance readings deviate from the known weights.
Calibration should be done using a proper calibration weight and following manufacturer's instructi...
PH range is 0-14. Calibration ensures accuracy by adjusting the PH meter to known standards.
PH range is from 0 to 14, with 7 being neutral
Acidic solutions have a PH below 7, while alkaline solutions have a PH above 7
Calibration involves adjusting the PH meter using buffer solutions of known PH values
Regular calibration ensures accurate PH measurements
I applied via Naukri.com and was interviewed before Aug 2021. There were 2 interview rounds.
Regulatory guidelines are essential for ensuring compliance with QMS standards.
ISO 9001:2015 is the most widely recognized QMS standard
FDA regulations apply to medical device manufacturers
EU MDR 2017/745 is the new regulation for medical devices in the European Union
Regulatory guidelines provide a framework for implementing and maintaining QMS
Non-compliance with regulatory guidelines can result in fines, legal action,
Change controls are procedures used to manage changes to a system or process.
Documenting the change request
Assessing the impact of the change
Obtaining approval for the change
Implementing the change
Testing the change
Reviewing and closing the change request
I applied via Walk-in and was interviewed before Nov 2021. There were 2 interview rounds.
These are technical terms related to UV calibration and water content analysis.
UV calibration parameters refer to the settings used to calibrate a UV spectrophotometer for accurate measurements.
ROI method stands for Region of Interest method, which is a technique used to analyze specific areas of an image or sample.
Water content and LOD (Limit of Detection) difference are important factors to consider when analyzing th
I appeared for an interview before Jan 2024.
I am a highly motivated and results-driven individual with a strong background in project management and team leadership.
Experienced in project management and team leadership
Highly motivated and results-driven
Strong communication and interpersonal skills
I appeared for an interview in Jan 2021.
Tests performed for HVAC include airflow measurement, temperature measurement, pressure measurement, and refrigerant leak detection.
Airflow measurement: Testing the volume of air being circulated by the HVAC system using an anemometer.
Temperature measurement: Checking the temperature of the air at various points in the system using thermometers or temperature sensors.
Pressure measurement: Assessing the pressure levels ...
Tests performed for tunnel
Permeability test
Water pressure test
Load test
Visual inspection
Geotechnical investigation
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Officer
169
salaries
| ₹1.7 L/yr - ₹5.9 L/yr |
Senior Officer
166
salaries
| ₹3.2 L/yr - ₹7 L/yr |
Medical Representative
122
salaries
| ₹1.2 L/yr - ₹4.8 L/yr |
Research Associate
101
salaries
| ₹1.9 L/yr - ₹5.1 L/yr |
Senior Research Associate
93
salaries
| ₹3 L/yr - ₹7 L/yr |
Hetero
Micro Labs
Biological E
USV