Filter interviews by
Be the first one to contribute and help others!
posted on 28 Mar 2024
posted on 28 Mar 2024
SDLC stands for Software Development Life Cycle, which is a process used by software development teams to design, develop, and test high-quality software.
SDLC consists of several phases including planning, analysis, design, implementation, testing, and maintenance.
Each phase has its own set of activities and deliverables to ensure the software meets the requirements and quality standards.
Examples of SDLC models include...
CAN protocol is a communication standard used in automotive and industrial applications.
CAN protocol stands for Controller Area Network
It is a message-based protocol used for communication between electronic control units (ECUs)
CAN protocol allows for high-speed communication and real-time data transmission
It is commonly used in automotive applications for functions such as engine control, transmission control, and bod...
posted on 16 Jan 2021
posted on 19 Apr 2021
posted on 3 Mar 2023
I applied via Campus Placement and was interviewed in Feb 2023. There were 2 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
Power factor is a measure of how efficiently electrical power is being used.
It is expressed as a decimal or a percentage.
A power factor of 1 means all the power is being used efficiently.
A power factor less than 1 means some power is being wasted.
Inductive loads like motors have a lagging power factor while capacitive loads like transformers hav
Types of motors: AC motors, DC motors, stepper motors. Types of switchgear protection: fuses, circuit breakers, relays.
AC motors: used in high power applications, such as industrial machinery and air conditioning systems
DC motors: used in low power applications, such as toys and small appliances
Stepper motors: used in precision applications, such as robotics and 3D printers
Fuses: protect electrical circuits from overlo...
posted on 11 Aug 2023
I applied via Naukri.com and was interviewed before Aug 2022. There were 3 interview rounds.
The area for AC can be calculated by multiplying the length and width of the room.
Measure the length and width of the room in feet or meters
Multiply the length by the width to get the area in square feet or square meters
For example, if the room is 10 feet long and 12 feet wide, the area for AC would be 120 square feet
posted on 31 Jan 2024
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
I applied via Walk-in and was interviewed before Dec 2020. There were 5 interview rounds.
SDLC stands for Software Development Life Cycle, which is a process used to design, develop, and test software.
SDLC is a framework that consists of several phases, including planning, analysis, design, implementation, testing, and maintenance.
Each phase has its own set of activities and deliverables that must be completed before moving on to the next phase.
The goal of SDLC is to ensure that software is developed effici...
Software testing methodologies are techniques used to test software for quality and functionality.
There are various testing methodologies such as Agile, Waterfall, and DevOps.
Agile methodology involves continuous testing and feedback throughout the development process.
Waterfall methodology involves testing at the end of each phase of development.
DevOps methodology involves testing in a continuous integration and delive...
Bombardier Transportation
Intact Green Services
Linfox Logistics
Mumbai Metro One