Filter interviews by
I applied via campus placement at Delhi College of Engineering (DCE), Delhi and was interviewed in Mar 2022. There were 2 interview rounds.
I was interviewed in Nov 2021.
Top trending discussions
Nitrogen gas is used in accumulators due to its inert properties and ability to maintain pressure for extended periods of time.
Nitrogen gas is inert, meaning it does not react with other substances, making it ideal for maintaining pressure without causing corrosion or contamination.
It is also non-flammable, which reduces the risk of fire hazards in accumulator systems.
Nitrogen gas has a stable temperature range, allowi...
Accumulator is used in WTG to store excess energy generated by the wind turbine for later use.
Accumulator helps in smoothing out the power output from the wind turbine.
It allows for energy storage when the demand is low and release of stored energy when the demand is high.
Accumulators can also help in providing backup power during periods of low wind.
Examples of accumulators used in WTG include batteries, flywheels, an
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.
I applied via Walk-in and was interviewed in Oct 2021. There was 1 interview round.
I applied via Walk-in and was interviewed before Nov 2019. There were 3 interview rounds.
Overhauling procedure of turbine and generator involves disassembly, inspection, repair, and reassembly.
Disassemble turbine and generator components
Inspect components for wear and damage
Repair or replace damaged components
Reassemble components and test for proper function
I applied via Approached by Company and was interviewed in Mar 2024. There was 1 interview round.
I applied via Other and was interviewed before Jul 2017. There were 3 interview rounds.
There are several types of dampings in case of vibration, including viscous damping, hysteretic damping, and structural damping.
Viscous damping: It occurs when a fluid or viscous material is used to dissipate energy and reduce vibration.
Hysteretic damping: It is caused by the internal friction within a material, which converts mechanical energy into heat.
Structural damping: It is inherent in the structure itself and is...
based on 10 reviews
Rating in categories
Assistant Manager
86
salaries
| ₹3 L/yr - ₹10.7 L/yr |
Electrical Engineer
72
salaries
| ₹2.5 L/yr - ₹8.5 L/yr |
Senior Manager
70
salaries
| ₹7.2 L/yr - ₹17.2 L/yr |
Engineer
68
salaries
| ₹2.8 L/yr - ₹9.2 L/yr |
Manager
46
salaries
| ₹6.1 L/yr - ₹14 L/yr |
Tata Power Delhi Distribution
Reliance Infrastructure
CESC
Torrent Power