Filter interviews by
A zero export device in a solar installation is a device that prevents excess solar energy from being exported back to the grid.
A zero export device is typically used in situations where the grid cannot handle the additional power generated by the solar installation.
It ensures that the solar energy is consumed locally or stored in batteries instead of being exported.
Zero export devices can be programmed to limit the ex...
Top trending discussions
I applied via Approached by Company
Cable size can be calculated based on current carrying capacity, voltage drop, and installation conditions.
Determine the current carrying capacity required for the cable based on the load
Calculate the voltage drop allowed for the cable based on the distance and voltage rating
Consider the installation conditions such as ambient temperature and grouping of cables
Use cable sizing charts or online calculators to find the a
Sq mm stands for square millimeter, a unit of area measurement.
Sq mm is a unit of measurement used to quantify the area of a two-dimensional space.
It is equal to the area of a square with sides measuring 1 millimeter each.
Commonly used in engineering and construction for measuring small areas.
Example: A sheet of paper may have dimensions of 210 mm x 297 mm, which is equivalent to 62370 sq mm.
I applied via Walk-in and was interviewed before Jan 2022. There were 2 interview rounds.
The number of leads in sqmm wire depends on the wire gauge and its application.
The number of leads in a sqmm wire can range from 1 to over 1000 depending on the wire gauge and its application.
For example, a 1 sqmm wire may have a single lead, while a 1000 sqmm wire may have over 1000 leads.
The number of leads in a wire can also depend on whether it is a single-core or multi-core wire.
In general, the larger the wire gau...
Sizes of cables and db box are determined by the electrical load and distance of the circuit.
The size of the cable is determined by the electrical load and the distance of the circuit.
The size of the distribution board (db) box is determined by the number of circuits and the size of the cables.
The cable size is usually specified in square millimeters (mm²) or American Wire Gauge (AWG).
The db box size is usually specifi...
Insulation types include solid, liquid, and gas. Examples include rubber, oil, and air.
Solid insulation includes materials like rubber, plastic, and paper
Liquid insulation includes materials like oil and transformer oil
Gas insulation includes materials like air, sulfur hexafluoride, and nitrogen
Other types of insulation include ceramic, mica, and glass
Examples of insulation used in electrical equipment include polyethy
Chemical earthing involves the use of chemicals to improve conductivity and reduce soil resistivity.
Normal earthing involves the use of a metal rod or plate buried in the ground to provide a low resistance path for fault current.
Chemical earthing involves the use of chemicals such as bentonite, salt, and charcoal to improve conductivity and reduce soil resistivity.
Chemical earthing is more effective in areas with high ...
Project Engineer
29
salaries
| ₹4.6 L/yr - ₹8.2 L/yr |
Civil Foreman
26
salaries
| ₹2.9 L/yr - ₹5 L/yr |
Assistant Engineer
18
salaries
| ₹4 L/yr - ₹6 L/yr |
Sales Manager
16
salaries
| ₹7.1 L/yr - ₹9 L/yr |
Project Engineer - Civil
16
salaries
| ₹4.8 L/yr - ₹8.2 L/yr |
Godrej Properties
Sobha
Prestige Group
DLF