Personal information and instruments details ask
I come from a close-knit family that values education and hard work, with diverse backgrounds and strong support for each other.
My father is an engineer, which instilled in me a love for problem-solving and analytical thinking.
My mother is a teacher, emphasizing the importance of education and lifelong learning.
I have two siblings; we often collaborate on projects, fostering teamwork and communication skills.
Family gat...
Top trending discussions
I applied via Walk-in and was interviewed before May 2021. There were 4 interview rounds.
posted on 20 Jun 2024
UV visible spectroscopy is a technique used to measure the absorption of ultraviolet and visible light by a substance.
UV visible spectroscopy involves passing UV and visible light through a sample and measuring the amount of light absorbed at different wavelengths.
It is commonly used in analytical chemistry to determine the concentration of a substance in a sample.
UV visible spectroscopy can also be used to study the e...
pH stands for potential of hydrogen and is a measure of acidity or alkalinity of a solution. It is a unitless scale ranging from 0 to 14.
pH measures the concentration of hydrogen ions in a solution, determining its acidity or alkalinity.
A pH of 7 is considered neutral, below 7 is acidic, and above 7 is alkaline.
Examples of pH levels: lemon juice (pH 2), water (pH 7), baking soda (pH 9).
I applied via Referral and was interviewed before May 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before May 2021. There were 3 interview rounds.
I applied via Walk-in and was interviewed before Feb 2020. There was 1 interview round.
DB1701 and HP5 columns are commonly used in chromatography due to their high thermal stability and wide range of applications.
DB1701 and HP5 columns are both stationary phases used in gas chromatography.
DB1701 column is a non-polar phase, while HP5 column is a polar phase.
DB1701 column is commonly used for analyzing volatile organic compounds (VOCs) in environmental samples.
HP5 column is often used for analyzing polar ...
I applied via Referral and was interviewed before Sep 2021. There were 4 interview rounds.
General attributes ,Basic knowledge,English,maths
I applied via Recruitment Consultant and was interviewed in Jan 2018. There were 5 interview rounds.
Production Officer
71
salaries
| ₹2.5 L/yr - ₹4.5 L/yr |
Officer
27
salaries
| ₹2.6 L/yr - ₹4.2 L/yr |
Senior Officer
26
salaries
| ₹3.3 L/yr - ₹6.5 L/yr |
Senior Production Officer
21
salaries
| ₹3.5 L/yr - ₹5.5 L/yr |
QC Officer
20
salaries
| ₹2.1 L/yr - ₹3.9 L/yr |
Aarti Industries
UPL
Coromandel International
PI Industries