Filter interviews by
Had coding, normal apti , code snippets
Developed a web-based project management system for a large corporation
Utilized Agile methodology for project development
Integrated with existing CRM system for seamless data flow
Implemented user-friendly interface for easy navigation
I applied via Referral and was interviewed before Apr 2021. There was 1 interview round.
Subnetting is dividing a network into smaller subnetworks. There are two types of routing: static and dynamic. Static routing is manually configured by the network administrator. The subnet mask of /27 is 255.255.255.224. STP is a protocol used to prevent loops in a network. Etherchannel is a technique used to combine multiple physical links into a single logical link. VLAN is a logical grouping of devices in a network...
I was interviewed before Dec 2019.
Polycom Group Series is a video conferencing system for businesses and organizations.
Allows for high-quality video and audio conferencing
Supports multiple participants in different locations
Integrates with various collaboration tools
Can be controlled through a remote or mobile app
Crestron's controlling protocols are used for home automation and control systems.
Crestron uses proprietary protocols for communication between devices.
Crestron's main protocol is called Crestron Home OS (CH5).
Other protocols used by Crestron include SIMPL Windows, Crestron Toolbox, and Crestron Studio.
These protocols allow for seamless integration and control of various devices in a home automation system.
Baud rate is the number of signal or symbol changes per second in a communication channel.
Baud rate is measured in bits per second (bps).
It determines the rate at which data is transmitted over a communication channel.
Higher baud rates allow for faster data transfer.
For example, a baud rate of 9600 means 9600 bits of data are transmitted per second.
RS232 protocol is a standard for serial communication. Third-party device control can be achieved using this protocol.
RS232 protocol is a standard for serial communication between devices.
Third-party device control can be achieved by sending commands over RS232.
Commands can be sent using a terminal emulator or programming language.
Examples of devices that can be controlled using RS232 include printers, scanners, and in
RS-485 is a serial communication protocol used for long-distance communication.
It is a half-duplex protocol
It can support up to 32 devices on a single bus
It uses differential signaling to reduce noise and increase range
It has a maximum data rate of 10 Mbps
It is commonly used in industrial automation and control systems
To control Polycom video conferencing via Crestron cp3, use the Polycom RealPresence API and Crestron SIMPL#Pro programming language.
Use the Polycom RealPresence API to send commands to the Polycom system
Create a SIMPL#Pro module to interface with the Crestron cp3
Map the commands from the API to the SIMPL#Pro module
Use the SIMPL#Pro module to send the mapped commands to the Polycom system
The Bss BLU-100 can be controlled over RS232 using a variety of commands.
The BLU-100 uses a proprietary protocol called HiQnet
Commands can be sent using a terminal emulator program
Examples of commands include setting input and output levels, muting channels, and adjusting EQ settings
Crestron application license has free and paid versions with different working details.
Crestron application is a software used for automation and control systems.
The free version has limited features and is meant for personal use.
The paid version has advanced features and is meant for commercial use.
The license is required to activate the software and access all its features.
The working details depend on the specific v
RS232 commands can be sent over IR port using an IR to RS232 converter.
Use an IR to RS232 converter to convert the IR signals to RS232 commands.
Connect the IR to RS232 converter to the device that needs to receive the commands.
Send the RS232 commands through the IR port using the converter.
Ensure that the IR port and the converter are compatible with each other and the device.
Test the connection and commands to ensure
AGC Networks interview questions for popular designations
Top trending discussions
Experienced PMO Executive with a background in project management and strategic planning.
Over 10 years of experience in leading project management offices
Skilled in developing and implementing project management processes
Strong background in strategic planning and resource allocation
Proven track record of delivering projects on time and within budget
Excellent communication and leadership skills
posted on 21 Jan 2025
Normal logical, verbal, and quantitative ability questions.
I applied via Campus Placement and was interviewed in Dec 2024. There were 3 interview rounds.
Hackathon on chatbot development website
posted on 25 Jan 2025
I was interviewed before Jan 2024.
posted on 2 Nov 2024
I applied via Campus Placement
90 min MCQ +coding test on hackerrank.
Use Floyd's Tortoise and Hare algorithm to detect cycle in a linked list.
Initialize two pointers, slow and fast, at the head of the linked list.
Move slow pointer by one step and fast pointer by two steps.
If they meet at some point, there is a cycle in the linked list.
Interview experience
based on 110 reviews
Rating in categories
Network Engineer
32
salaries
| ₹1.9 L/yr - ₹5 L/yr |
Avaya Support Engineer
25
salaries
| ₹2 L/yr - ₹6 L/yr |
Technical Support Engineer
17
salaries
| ₹1.8 L/yr - ₹6 L/yr |
AV Engineer
15
salaries
| ₹1.5 L/yr - ₹3.8 L/yr |
Service Engineer
13
salaries
| ₹2.1 L/yr - ₹6.2 L/yr |
Tata Communications
Tech Mahindra
HCLTech
Wipro