The cable length for PA cables varies depending on the specific application, while the diameter is typically determined by the current carrying capacity and voltage requirements.
Cable length for PA cables can range from a few meters to several hundred meters, depending on the distance between the PA system and the speakers.
The diameter of PA cables is usually determined by the current carrying capacity and voltage requ...
There are two main types of smoke detectors: ionization and photoelectric.
Ionization smoke detectors use a small amount of radioactive material to ionize the air and detect smoke particles.
Photoelectric smoke detectors use a light beam to detect smoke particles in the air.
Dual sensor smoke detectors combine both ionization and photoelectric technologies for more comprehensive detection.
I am open to working from the office as needed for collaboration and team communication.
I believe in the importance of face-to-face interactions for effective communication and teamwork
I am flexible and willing to work from the office when required for project meetings or discussions
I understand the benefits of being physically present in the office for certain tasks or projects
I applied via Naukri.com and was interviewed in Mar 2023. There were 2 interview rounds.
Environment conditions such as temperature, humidity, and cleanliness are crucial for panel installation.
Temperature should be within specified range to prevent damage to components.
Humidity levels should be controlled to avoid condensation and corrosion.
Cleanliness is important to prevent dust and debris from affecting performance.
Proper ventilation is necessary to prevent overheating.
Avoid exposure to direct sunlight...
Restricted Earth Fault is a type of fault in electrical systems where the fault current is limited to a specific section of the system.
Occurs when a fault current flows from a phase conductor to the earth through a restricted path
Usually detected by a relay that monitors the current imbalance between the phase and neutral conductors
Helps in quickly identifying and isolating the fault to prevent damage to equipment and ...
Differential earth fault is a type of fault in electrical systems where the current flowing into and out of the system is not equal due to an earth fault.
Differential earth fault protection is used to detect such faults by comparing the current entering and leaving the system.
It is important for safety as it helps prevent damage to equipment and potential electric shocks.
Examples of differential earth fault protection ...
Transformer insulation class indicates the temperature at which the insulation can operate safely.
Transformer insulation class is denoted by a letter (e.g. A, B, F, H) which corresponds to a maximum allowable temperature rise above ambient.
Higher insulation classes can withstand higher temperatures, providing better protection for the transformer.
Common insulation classes include A (105°C), B (130°C), F (155°C), and H
Implement a scheme using temperature sensors to detect transformer temperature.
Install temperature sensors at key points on the transformer
Set up a monitoring system to continuously track temperature readings
Establish temperature thresholds for alerts and shutdowns
Implement a cooling system to regulate temperature if needed
Voltage levels as per standards vary depending on the application and region, with common levels including 110V, 220V, and 415V.
Voltage levels can vary depending on the application and region
Common residential voltage levels include 110V and 220V
Industrial voltage levels are typically higher, such as 415V
International standards like IEC and ANSI provide guidelines for voltage levels
Molded Case Circuit Breakers (MCCBs) are types of circuit breakers that provide protection against overcurrents.
Thermal-magnetic MCCB: Trips when a current overload or short circuit is detected.
Electronic MCCB: Uses electronic components for more precise and adjustable protection.
Compact MCCB: Smaller in size for limited space installations.
Adjustable MCCB: Allows for manual adjustment of trip settings.
Motor protection...
Factors to consider for lighting calculation include type of space, desired lighting levels, fixture efficiency, and lighting layout.
Type of space (office, warehouse, retail, etc.)
Desired lighting levels (measured in lux or foot-candles)
Fixture efficiency (lumens per watt)
Lighting layout (spacing and placement of fixtures)
Natural lighting sources (windows, skylights)
Color rendering index (CRI) for accurate color repres...
I applied via Referral and was interviewed before Jul 2021. There were 2 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Mar 2021. There were 4 interview rounds.
I applied via Naukri.com and was interviewed in Jun 2021. There were 3 interview rounds.
I applied via LinkedIn and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Recruitment Consulltant
based on 2 interviews
Interview experience
based on 82 reviews
Rating in categories
Project Engineer
581
salaries
| ₹0 L/yr - ₹0 L/yr |
R&D Engineer
324
salaries
| ₹0 L/yr - ₹0 L/yr |
Financial Analyst
256
salaries
| ₹0 L/yr - ₹0 L/yr |
Design Engineer
237
salaries
| ₹0 L/yr - ₹0 L/yr |
Associate Project Engineer
209
salaries
| ₹0 L/yr - ₹0 L/yr |
Siemens
Schneider Electric
Emerson Electric Co.
Honeywell International India