Filter interviews by
posted on 14 Apr 2023
I applied via Referral and was interviewed before Apr 2022. There were 4 interview rounds.
Project control Moc review
posted on 13 Nov 2023
I handled a variety of equipment in my last company, including pumps, compressors, and HVAC systems.
Pumps
Compressors
HVAC systems
Top trending discussions
posted on 14 Jun 2024
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.
Analyzed thermal performance of parabolic solar collector for M.Tech project
Researched various materials for collector construction
Conducted experiments to measure heat transfer efficiency
Analyzed data to optimize collector design
Compared results with theoretical models
Presented findings in a detailed report
Energy management of a plant involves optimizing energy usage to reduce costs and environmental impact.
Implementing energy-efficient technologies and practices
Monitoring energy consumption and identifying areas for improvement
Utilizing renewable energy sources where possible
Regular maintenance of equipment to ensure optimal performance
Training staff on energy conservation practices
posted on 3 Jul 2024
posted on 10 Aug 2023
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
posted on 18 Dec 2022
I applied via Company Website and was interviewed in Nov 2022. There were 2 interview rounds.
posted on 8 Aug 2022
posted on 29 Apr 2022
I applied via Naukri.com and was interviewed in Oct 2021. There were 2 interview rounds.
Calculating cooling tower TR, boiler efficiency, and types and capacity of chilling plant compressors.
Cooling tower TR can be calculated using the formula: TR = (500 x GPM x Delta T)/12000
Boiler efficiency can be calculated using the formula: Efficiency = (Output/Input) x 100
Types of compressors include reciprocating, rotary screw, centrifugal, and scroll.
Capacity of compressors is measured in tons of refrigeration (TR...
Answering questions related to Maintenance Engineer interview.
Types of boilers include fire tube, water tube, and electric boilers.
Chilling plant capacity can be calculated by multiplying the flow rate by the temperature difference.
Colour coding in industry is used to identify pipes, wires, and equipment based on their function or contents.
Schedule maintenance is planned maintenance that is performed at regular interva...
posted on 24 May 2022
based on 2 interviews
Interview experience
Assistant Manager
617
salaries
| ₹4.5 L/yr - ₹12.8 L/yr |
Deputy Manager
577
salaries
| ₹6.7 L/yr - ₹17.5 L/yr |
Executive
523
salaries
| ₹2.2 L/yr - ₹7.7 L/yr |
Plant Operator
341
salaries
| ₹1.6 L/yr - ₹5.2 L/yr |
Senior Executive
321
salaries
| ₹3.3 L/yr - ₹10.3 L/yr |
Vinati Organics
Atul
Navin Fluorine International
Solvay Specialities