Filter interviews by
An e Bill of lading is an electronic version of a traditional bill of lading used in shipping and logistics.
It serves as a receipt of goods, a contract of carriage, and a document of title.
It is used in international trade to confirm receipt of goods and their shipment.
E Bill of lading can be transmitted electronically, reducing paperwork and increasing efficiency.
To convince the customer, focus on understanding their needs, building trust, providing solutions, and demonstrating value.
Listen actively to understand the customer's needs and concerns
Build trust by being honest, transparent, and reliable
Provide tailored solutions that address the customer's specific pain points
Demonstrate the value of your product or service through case studies, testimonials, or product demos
I applied via Approached by Company and was interviewed before Aug 2022. There were 2 interview rounds.
I have a Bachelor's degree in Business Administration with a focus on International Business.
Bachelor's degree in Business Administration
Focus on International Business
I applied via Recruitment Consulltant
Ficus on past experience n entry based on target volume & cost factor
Top trending discussions
posted on 9 Mar 2024
I was interviewed before Mar 2023.
Financial Inclusion in India is improving but still faces challenges in reaching rural and marginalized populations.
Government initiatives like Jan Dhan Yojana have increased access to banking services
Digital payment systems like UPI have made transactions easier and more accessible
Challenges remain in reaching rural and marginalized populations due to lack of awareness and infrastructure
Microfinance institutions play ...
My expected CTC is negotiable based on the job role, responsibilities, and benefits offered.
My expected CTC is based on industry standards and my level of experience.
I am open to discussing the salary range during the interview process.
I am looking for a competitive salary package that aligns with my skills and qualifications.
I applied via Naukri.com and was interviewed in May 2022. There were 3 interview rounds.
Salary and work experience
Work for shipping industry
posted on 16 Dec 2023
I applied via LinkedIn and was interviewed in Jun 2023. There were 2 interview rounds.
The hipot test can be done on a cable multiple times depending on the specific requirements and standards.
The number of times a hipot test can be done on a cable depends on the cable's specifications and the testing requirements.
Generally, a hipot test is performed once during the manufacturing process to ensure the cable's insulation integrity.
However, additional hipot tests may be conducted during the cable's lifespa...
If battery polarity is inverse with respect to battery charger, it can lead to damage or malfunction.
Inverse polarity can cause short circuits or overheating.
It can damage the battery, charger, or both.
Reverse polarity protection circuits can prevent damage.
Always double-check the polarity before connecting the battery to the charger.
There are several types of earthing used in electrical systems.
The most common types of earthing are:
- TN-S system: Separate neutral and protective earth conductors
- TN-C system: Combined neutral and protective earth conductors
- TN-C-S system: Combination of TN-S and TN-C systems
- TT system: Separate earth electrode for each electrical installation
- IT system: No direct connection between earth and neutral
Each type of ...
I have handled various quality documents such as quality control plans, inspection reports, and non-conformance reports.
Quality control plans
Inspection reports
Non-conformance reports
Tests done on power transformers include insulation resistance, turns ratio, winding resistance, and dielectric tests.
Insulation resistance test checks the insulation quality of the transformer.
Turns ratio test measures the ratio of primary to secondary turns.
Winding resistance test determines the resistance of transformer windings.
Dielectric tests assess the dielectric strength and insulation properties of the transfo...
Hipot testing is a process used to verify the insulation integrity of busbars, breakers, cables, and transformers.
Hipot testing involves applying a high voltage to the component being tested.
The purpose is to check for any insulation breakdown or leakage current.
For busbars and cables, the test is typically performed between the conductor and the ground.
For breakers and transformers, the test is performed between diffe...
IR, WR, and CR are abbreviations used in different contexts. IR stands for Infrared, WR stands for Weather Resistant, and CR stands for Compression Ratio.
IR refers to Infrared, which is a type of electromagnetic radiation with longer wavelengths than visible light.
WR is used to indicate that a product or material is designed to withstand various weather conditions.
CR is a term commonly used in engineering and physics t...
Tap changer in a transformer is located on the high voltage winding side to regulate the voltage output.
Tap changer is typically located on the high voltage winding side of a transformer.
It is used to adjust the turns ratio and regulate the voltage output.
If the voltage output in the secondary decreases, the tap changer will be moved to a higher tap position to increase the voltage.
posted on 24 Mar 2021
It was good
Good
posted on 3 Feb 2022
I applied via Recruitment Consulltant and was interviewed in Jan 2022. There were 2 interview rounds.
posted on 23 Nov 2023
I applied via Naukri.com and was interviewed in May 2023. There were 3 interview rounds.
based on 3 interviews
Interview experience
based on 38 reviews
Rating in categories
Deputy Manager
12
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
11
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Executive
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Customer Service Executive
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Sales Manager
7
salaries
| ₹0 L/yr - ₹0 L/yr |
Maersk Line
CMA CGM
Mediterranean Shipping Company
Hapag-Lloyd