Filter interviews by
I applied via Walk-in and was interviewed in Oct 2024. There was 1 interview round.
To check the motor, you can perform various tests and inspections to ensure it is functioning properly.
Check for any physical damage or wear on the motor casing
Inspect the wiring connections for any loose or damaged wires
Measure the voltage and current going into the motor to ensure it is within the specified range
Test the motor's insulation resistance to check for any faults
Run the motor under load to see if it operat
Power analysis involves measuring and analyzing the electrical power consumption of a system or device.
Identify the components of the system or device that consume power.
Measure the current and voltage across these components using appropriate instruments.
Calculate the power consumption using the formula P = VI, where P is power, V is voltage, and I is current.
Analyze the power consumption data to identify any ineffici...
A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction.
Transformers are used to increase or decrease voltage levels in electrical circuits.
They consist of two coils of wire, known as the primary and secondary coils.
Examples of transformers include power transformers used in electrical substations and voltage transformers in electronic devices.
Top trending discussions
I applied via Approached by Company and was interviewed before Sep 2023. There was 1 interview round.
posted on 19 Sep 2024
I applied via Naukri.com and was interviewed before Sep 2023. There was 1 interview round.
A generator is a device that converts mechanical energy into electrical energy.
Generates electricity through electromagnetic induction
Common types include diesel generators, gas generators, and wind turbines
Used in power plants, homes, and businesses for backup power
A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction.
Consists of two coils of wire, known as primary and secondary coils
Primary coil receives electrical energy and creates a magnetic field
Magnetic field induces a voltage in the secondary coil, transferring energy
Used to step up or step down voltage levels in power distribution
Examples include power tr...
posted on 5 Apr 2022
I applied via Walk-in and was interviewed in Mar 2022. There was 1 interview round.
posted on 27 Jun 2023
I applied via Recruitment Consulltant and was interviewed in May 2023. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Jan 2023. There were 2 interview rounds.
Starters are used to control the starting and stopping of motors. Different types of starters are used based on the motor's power rating and application.
Direct On-Line (DOL) Starter
Star-Delta Starter
Auto Transformer Starter
Soft Starter
Variable Frequency Drive (VFD) Starter
Parallel operation of transformers refers to connecting two or more transformers with the same voltage ratio and frequency to supply a common load.
Parallel operation increases the capacity of the system and provides redundancy.
The transformers must have the same voltage ratio, impedance, and phase angle.
Proper synchronization is necessary to avoid circulating currents.
Parallel operation can be achieved by using a commo...
I applied via Naukri.com and was interviewed in Dec 2022. There were 4 interview rounds.
Realated to electrical maintainence
posted on 29 Nov 2022
I applied via Walk-in and was interviewed in May 2022. There was 1 interview round.
The capacity of a furnace refers to its heating output, typically measured in BTUs or tons.
Furnace capacity is determined by the amount of heat it can produce.
It is usually measured in BTUs (British Thermal Units) or tons.
Higher capacity furnaces can produce more heat and are suitable for larger spaces.
For example, a furnace with a capacity of 80,000 BTUs can heat a larger area compared to one with a capacity of 40,000
Drive components in CCM department are the parts that enable the motor to function properly.
Drive components include motors, gears, belts, and pulleys.
They work together to transfer power from the motor to the machine.
The components must be properly sized and aligned to ensure efficient operation.
Examples of machines that use drive components include conveyor belts, pumps, and fans.
I applied via Walk-in and was interviewed in May 2022. There were 2 interview rounds.
posted on 3 Jun 2022
I applied via campus placement at Malviya National Institute of Technology (NIT), Jaipur and was interviewed in May 2022. There were 3 interview rounds.
Reasoning and aptitude with technical
based on 1 review
Rating in categories
Assistant Engineer
201
salaries
| ₹1.8 L/yr - ₹4.5 L/yr |
Production Engineer
155
salaries
| ₹1.8 L/yr - ₹7 L/yr |
Assistant Manager
139
salaries
| ₹4.2 L/yr - ₹12 L/yr |
Senior Engineer
105
salaries
| ₹2.4 L/yr - ₹8 L/yr |
Engineer
102
salaries
| ₹2.2 L/yr - ₹5.5 L/yr |
Jindal Stainless
Salem Stainless Steel Suppliers
Hisar Metal Industries
Ratnamani Metals and Tubes