i
Valmet
Filter interviews by
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance on high and low voltage breakers, motors, and transformers.
Test and calibrate various protection relays for motors, transformers, and generators.
Conduct transformer oil BDV test, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, instal...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, and relays.
Perform regular maintenance tasks on high and low voltage breakers, motors, and transformers.
Test and calibrate protection relays for motors, transformers, and generators.
Conduct transformer oil BDV tests, thermal scanning, and earth fault and prediction tests.
Terminate high voltage motors, install...
Preventive and corrective maintenance of various electrical equipment including breakers, motors, transformers, switches, relays, and testing/calibration of protections.
Preventive maintenance of H.V & LV breakers, motors, transformers, switches, etc.
Corrective maintenance of HV/MV/LV switchgears, breakers, cubicles, etc.
Testing and calibration of various protection relays for motors, transformers, generators.
Transforme...
I applied via Recruitment Consultant and was interviewed in May 2021. There were 3 interview rounds.
Stall in a motor refers to a condition where the motor stops rotating despite the presence of power supply.
Stall occurs when the motor is overloaded or when there is a mechanical obstruction preventing the motor from rotating.
It can also occur when the motor is underpowered or when there is a fault in the electrical system.
Stall can cause damage to the motor and other components if not addressed promptly.
Examples of mo...
UPS stands for Uninterruptible Power Supply. It is an electrical device that provides emergency power to a load when the input power source fails.
UPS has three main components: battery, inverter, and rectifier.
The battery provides backup power during a power outage.
The rectifier converts AC power to DC power to charge the battery.
The inverter converts DC power from the battery to AC power to supply the load.
UPS also ha...
I appeared for an interview before Mar 2024, where I was asked the following questions.
Wet leg filling involves filling a differential pressure transmitter's wet leg with liquid for accurate measurement.
Identify the wet leg location and ensure safety protocols are followed.
Use a suitable filling liquid, typically water or a specific process fluid.
Connect a filling line to the wet leg and open the valve to allow liquid flow.
Monitor the filling process to avoid overfilling and ensure proper liquid level.
Ch...
I applied via Recruitment Consultant and was interviewed before Jun 2019. There were 4 interview rounds.
I appeared for an interview in Oct 2019.
I applied via Recruitment Consultant and was interviewed before Jun 2019. There were 3 interview rounds.
Answering questions related to confined space job, alignment of pump and motor, types of gaskets and valves, and troubleshooting reciprocating compressor.
Safety watch is responsible for monitoring the workers inside the confined space and ensuring their safety.
Alignment of pump and motor can be done using dial indicators or laser alignment tools.
Different types of gaskets include spiral wound, ring joint, and sheet gas...
posted on 5 Jan 2023
I appeared for an interview in Dec 2022.
posted on 25 Mar 2023
I applied via Job Fair and was interviewed in Feb 2023. There were 2 interview rounds.
Instrumentation equipment refers to devices used to measure, control, and monitor various parameters in industrial processes.
Instruments like pressure gauges, flow meters, and temperature sensors are commonly used in instrumentation.
Control valves and actuators are used to regulate the flow of fluids or gases.
Programmable Logic Controllers (PLCs) are used for automation and control of processes.
Analytical instruments l...
A PLC panel wiring diagram is a visual representation of the electrical connections and components in a programmable logic controller panel.
A PLC panel wiring diagram shows the layout and connections of various components such as power supplies, input/output modules, relays, and sensors.
It helps technicians understand how the electrical signals flow within the panel and how different devices are interconnected.
The diag...
A control valve is a device used to regulate the flow of fluid or gas in a process system.
Control valves are commonly used in industries such as oil and gas, chemical, and power plants.
They can be operated manually or automatically through an electrical or pneumatic signal.
Control valves consist of a valve body, actuator, and positioner.
They can control variables such as flow rate, pressure, temperature, and level.
Exam...
A transmitter is a device used in instrumentation to convert a physical measurement into an electrical signal.
Transmitters are commonly used in industries such as oil and gas, chemical, and power plants.
They are used to measure variables such as pressure, temperature, flow rate, level, and pH.
Transmitters typically consist of a sensing element, signal conditioning circuitry, and an output signal.
The sensing element det...
Flow meters are devices used to measure the flow rate of a fluid or gas.
Flow meters are commonly used in industries such as oil and gas, water treatment, and manufacturing.
They can measure flow rates in various units such as liters per minute, cubic meters per hour, or gallons per minute.
Different types of flow meters include electromagnetic, ultrasonic, turbine, and differential pressure flow meters.
Flow meters can be...
based on 1 interview
Interview experience
Project Engineer
41
salaries
| ₹2.5 L/yr - ₹12 L/yr |
Design Engineer
36
salaries
| ₹4 L/yr - ₹9.9 L/yr |
Engineer
31
salaries
| ₹6.5 L/yr - ₹11.6 L/yr |
Applications Engineer
26
salaries
| ₹3.5 L/yr - ₹12.3 L/yr |
Senior Engineer
22
salaries
| ₹6 L/yr - ₹15 L/yr |
Shell
Schlumberger
Linde India
Baker Hughes