Equipment used in steam turbine include turbine blades, nozzles, casing, rotor, bearings, and governor.
Turbine blades: convert steam energy into mechanical energy
Nozzles: control the flow of steam into the turbine
Casing: contains and directs the steam flow through the turbine
Rotor: connected to the turbine blades and rotates to generate power
Bearings: support the rotor and reduce friction
Governor: regulates the speed o
Woodward 505 is a versatile control system used in industrial applications.
The Woodward 505 is a widely used control system in industries such as power generation, oil and gas, and marine.
It offers advanced features like PID control, sequencing, and communication capabilities.
The Woodward 505 is known for its reliability and robustness in harsh operating environments.
It can be easily integrated with various types of se
The Honeywell DCS (Distributed Control System) is a modular system consisting of controllers, I/O modules, and operator stations.
Consists of controllers, I/O modules, and operator stations
Uses a network to communicate between components
Allows for centralized control and monitoring of processes
Supports various communication protocols such as Modbus, OPC, etc.
Example: Honeywell Experion PKS
PID stands for Proportional-Integral-Derivative, a control loop feedback mechanism used in engineering.
PID is a control algorithm that calculates an error value as the difference between a desired setpoint and a measured process variable.
Proportional (P) control responds to the current error value.
Integral (I) control accumulates past errors to correct the present error.
Derivative (D) control predicts future errors bas...
To assign a new channel in Honeywell DCS, you need to access the configuration software and follow the steps to add the channel.
Access the Honeywell DCS configuration software
Navigate to the channel configuration section
Add a new channel by specifying the channel number, type, and other relevant parameters
Save the changes and verify the new channel is successfully assigned
Interlocks and permissives are safety mechanisms in place to prevent unsafe operation of boiler and turbine systems.
Interlocks prevent certain actions from taking place unless specific conditions are met
Permissives allow certain actions to take place only if specific conditions are met
Example of interlock: Boiler feed pump interlock prevents the boiler from starting unless the feed pump is running
Example of permissive:...
Basic aptitude from rs agrawal book is sufficient
posted on 25 Dec 2023
I was interviewed in Jun 2023.
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
The repeated burning of a 22 kW AOP motor CT cable may be due to overloading, short circuits, poor insulation, or incorrect cable sizing.
Check for overloading of the motor causing excessive heat in the cable
Inspect for short circuits in the motor or the wiring
Ensure proper insulation of the cable to prevent overheating
Verify if the cable size is appropriate for the motor's power requirements
Bypassing the CT of an AOP motor can lead to overcurrent and damage to the motor.
Bypassing the CT can result in the motor drawing excessive current.
This can lead to overheating of the motor windings.
Overcurrent can cause damage to the motor components.
It can also pose a safety risk due to potential electrical faults.
posted on 7 Oct 2024
I applied via LinkedIn and was interviewed in Sep 2024. There was 1 interview round.
Synchronisation process of a plant involves matching the frequency, voltage, and phase angle of the incoming generator with the grid.
Ensure the generator frequency matches the grid frequency (50Hz or 60Hz).
Match the voltage levels of the generator with the grid.
Adjust the phase angle of the generator to synchronize with the grid.
Use synchronizing equipment like synchroscope or synchronizing lamps to ensure proper synch...
Alternator and transformer protection systems are essential for preventing damage and ensuring safe operation.
Alternator protection systems typically include overcurrent, overvoltage, and reverse power protection to safeguard the alternator from damage.
Transformer protection systems often involve differential protection, overcurrent protection, and temperature monitoring to prevent overheating and insulation breakdown.
...
DCS tag assigning process involves assigning unique names to process variables for monitoring and control.
DCS tag assigning process is crucial for efficient process control and monitoring.
Each tag represents a process variable and is assigned a unique name for easy identification.
Tags can be assigned manually or automatically based on the process requirements.
Tag naming conventions should be consistent and follow indus...
I applied via Walk-in and was interviewed before May 2020. There was 1 interview round.
based on 2 interviews
Interview experience
based on 3 reviews
Rating in categories
Assistant Manager
40
salaries
| ₹0 L/yr - ₹0 L/yr |
Project Executive
24
salaries
| ₹0 L/yr - ₹0 L/yr |
Project Manager
10
salaries
| ₹0 L/yr - ₹0 L/yr |
Service Engineer
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager Commercial
7
salaries
| ₹0 L/yr - ₹0 L/yr |
L&T Construction
Tata Projects
Sterling & Wilson
Voltas