i
Torrent Pharmaceuticals
Filter interviews by
I applied via Naukri.com and was interviewed in Sep 2023. There were 2 interview rounds.
Top trending discussions
A 50 ppm solution contains 50 parts of solute per million parts of solution.
ppm stands for parts per million.
It is a measure of concentration.
In a 50 ppm solution, there are 50 parts of solute per million parts of solution.
For example, if we have a 1 million mL solution, there would be 50 mL of solute in it.
I applied via Walk-in and was interviewed before Jan 2020. There was 1 interview round.
Mass spectrometry is a technique used to identify and quantify molecules based on their mass-to-charge ratio.
Electrospray ionization (ESI)
Matrix-assisted laser desorption/ionization (MALDI)
Gas chromatography-mass spectrometry (GC-MS)
Liquid chromatography-mass spectrometry (LC-MS)
Time-of-flight mass spectrometry (TOF-MS)
UV spectrometry is a technique that measures the absorption or transmission of ultraviolet light by a sample.
UV spectrometry is based on the principle that different molecules absorb UV light at specific wavelengths.
It is commonly used in analytical chemistry to determine the concentration of a substance in a sample.
UV spectrometry can be used to analyze the purity of a compound or identify unknown substances.
The instr...
To prepare 0.1 N HCl and NaOH, you need to calculate the required amount of the respective chemicals and dilute them in water.
Calculate the molar mass of HCl and NaOH
Determine the volume of solution needed
Use the formula: Normality (N) = (Number of equivalents / Volume of solution in liters)
For 0.1 N HCl, calculate the number of equivalents of HCl and dilute it to the desired volume
For NaOH, calculate the number of equ...
Quality assurance is the process of ensuring that products or services meet the desired level of quality.
It involves establishing standards and procedures to ensure that products or services meet those standards.
It includes monitoring and evaluating the quality of products or services to identify areas for improvement.
It also involves taking corrective action when necessary to address quality issues.
Examples include co...
Recall definitions
Recall: the ability to retrieve information from memory
Definition: a statement that explains the meaning of a word or phrase
Research: the systematic investigation into and study of materials and sources in order to establish facts and reach new conclusions
Associate: a person who works with others towards a common goal
Hypothesis: a proposed explanation for a phenomenon
Experiment: a scientific procedure...
The type of HPLC used depends on the specific research requirements and objectives.
There are several types of HPLC systems available, including reverse phase, normal phase, ion exchange, size exclusion, and affinity chromatography.
The choice of HPLC system depends on the properties of the analyte, such as polarity, size, charge, and affinity.
For example, reverse phase HPLC is commonly used for the separation of nonpola...
UV detectors and HPLC detectors are used in research to analyze and quantify substances.
UV detectors are commonly used in UV-visible spectroscopy to measure the absorption of light by a sample at different wavelengths.
HPLC detectors are used in high-performance liquid chromatography to detect and quantify the components of a mixture.
Common types of UV detectors include diode array detectors (DAD) and photodiode array d...
Matrix in MALDI MS system is a substance used to assist in ionization of the sample for analysis.
Matrix is a substance that absorbs energy from the laser and transfers it to the sample, causing ionization.
The choice of matrix depends on the type of sample being analyzed.
Common matrices include alpha-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid (SA).
I applied via Referral and was interviewed in Mar 2020. There was 1 interview round.
Data integrity is crucial for accurate decision-making and maintaining trust in the organization.
Data integrity ensures that data is accurate, complete, and consistent.
It is important to have proper data management policies and procedures in place.
Regular data audits and checks should be conducted to ensure data integrity.
Examples of data integrity violations include data entry errors, system glitches, and unauthorized...
posted on 10 Jul 2017
I appeared for an interview before Jul 2016.
posted on 13 Jun 2022
I applied via Approached by Company and was interviewed before Jun 2021. There were 2 interview rounds.
posted on 6 Feb 2021
I applied via Recruitment Consultant and was interviewed in Aug 2020. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Sep 2018. There were 5 interview rounds.
Seeking new challenges and opportunities for growth.
Desire for new challenges and opportunities for growth
Seeking a more stimulating work environment
Looking to expand skill set and knowledge
Company restructuring or downsizing
Relocation to a new area
I applied via Company Website and was interviewed in Nov 2019. There were 3 interview rounds.
I was a Senior Sales Associate responsible for managing a team of sales representatives and achieving sales targets.
Managed a team of sales representatives
Set and achieved sales targets
Provided training and guidance to new team members
Analyzed sales data and implemented strategies to improve performance
The reagent addition rate for exothermic reaction can be found by monitoring the temperature and adjusting the rate accordingly.
Start with a small addition rate and gradually increase it while monitoring the temperature.
Use a thermometer or temperature sensor to measure the temperature.
Adjust the rate based on the temperature changes to maintain a steady reaction rate.
Consider the reaction kinetics and the heat transfe...
A PID temperature indicator controls temperature by adjusting heating/cooling based on feedback from sensors.
PID stands for Proportional-Integral-Derivative, which are the three control modes used to adjust temperature.
The indicator receives input from temperature sensors and compares it to the desired temperature setpoint.
Based on the difference between the two, the PID controller adjusts the heating/cooling output to...
MTSR, DSC, and TSC are metrics used in call centers to measure performance and efficiency.
MTSR stands for Mean Time to Service Request and measures the average time it takes for a customer's service request to be resolved.
DSC stands for Delayed Service Calls and measures the number of service calls that were not resolved within a certain timeframe.
TSC stands for Total Service Calls and measures the total number of serv...
XRD is a technique used to determine the crystal structure of a material. Crystalline and amorphous materials show different patterns.
XRD stands for X-ray diffraction
Crystalline materials have a regular, repeating pattern of atoms while amorphous materials lack this pattern
XRD patterns of crystalline materials show sharp peaks while amorphous materials show broad peaks
XRD can be used to identify unknown crystalline mat...
The degree of freedom of water at triple point is 0.
Triple point is the temperature and pressure at which solid, liquid, and gas phases of a substance coexist in thermodynamic equilibrium.
At triple point, the degree of freedom of a substance is zero because all three phases coexist in equilibrium.
Water has a triple point at 273.16 K (0.01 °C) and a pressure of 611.73 Pa.
At triple point, water can exist as ice, liquid w
Risk is the possibility of loss or harm occurring due to uncertain events or circumstances.
Risk involves uncertainty and the potential for negative consequences.
It can be managed through risk assessment, mitigation, and transfer.
Examples of risks include financial risks, health risks, and environmental risks.
Risk can also present opportunities for growth and innovation.
The power required for a pump can be calculated using the formula: Power = (Flow rate x Head) / Efficiency
Calculate the flow rate of the pump
Determine the head or pressure required
Consider the efficiency of the pump
Use the formula: Power = (Flow rate x Head) / Efficiency
Example: If the flow rate is 1000 liters per minute, the head is 50 meters, and the efficiency is 80%, the power required would be (1000 x 50) / 0.8 =
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Executive
2.2k
salaries
| ₹2.2 L/yr - ₹11.4 L/yr |
Assistant Manager
573
salaries
| ₹6.2 L/yr - ₹20 L/yr |
Medical Representative
371
salaries
| ₹1.3 L/yr - ₹5.8 L/yr |
Technical Assistant
350
salaries
| ₹1.7 L/yr - ₹5 L/yr |
Scientist II
228
salaries
| ₹3.5 L/yr - ₹13.1 L/yr |
Cipla
Dr. Reddy's
Lupin
Zydus Lifesciences