Swati Spentose
Career Upcrest Interview Questions and Answers
Q1. Why peak shape is braod or sharp when we perform melting range
Peak shape in melting range can be broad or sharp depending on factors like sample purity, heating rate, and instrument calibration.
Broad peak shape can indicate impurities or a mixture of compounds in the sample.
Sharp peak shape suggests a pure compound with a narrow melting range.
Heating rate affects peak shape, with slower rates often resulting in sharper peaks.
Instrument calibration and resolution can also impact peak shape.
Example: A sample containing impurities may exhi...read more
Q2. Which column are used during compositional accuracy of HPLC calibration
The columns used during compositional accuracy of HPLC calibration are known as reference standards.
Reference standards are used to ensure the accuracy and precision of HPLC calibration.
These standards are typically composed of known compounds that are used to calibrate the HPLC system.
The reference standards are run through the HPLC system and the resulting data is compared to the expected values.
If the results are within an acceptable range, the HPLC system is considered to...read more
Q3. Why caffeine are used in HPLC calibration
Caffeine is used in HPLC calibration as a reference compound due to its unique properties.
Caffeine has a well-defined retention time and UV absorbance spectrum, making it a reliable reference compound.
It is also non-toxic and easily available, making it a convenient choice for calibration.
Caffeine is used to determine the retention time, peak shape, and resolution of the HPLC system.
It is also used to check the accuracy and precision of the HPLC method.
Caffeine is added to th...read more
Q4. Why acetone are used in HPLC calibration
Acetone is used in HPLC calibration as a solvent and to remove impurities.
Acetone is a common solvent used in HPLC calibration
It is used to dissolve the sample and standards
Acetone is also used to remove impurities from the HPLC system
It is a volatile solvent and evaporates quickly
Acetone is compatible with most HPLC columns and detectors
Q5. Q.1 if analyst mistankenly fit the column in opposite direction in HPLC what happen? Q.2 Define the type of impurities ? Q.3 what is force degradation. Q.4 What is the other methods used for reaction monitoring...
read moreAnswering questions related to HPLC, impurities, force degradation, solvent classification, and reaction monitoring.
If a column is fitted in the opposite direction in HPLC, it can lead to inaccurate results.
Impurities can be classified as organic, inorganic, or residual solvents.
Force degradation is the process of intentionally subjecting a drug substance to stress conditions to evaluate its stability.
Other methods for reaction monitoring include UV-Vis spectroscopy, NMR spec...read more
Q6. Which parameter of Gas chromotography
The parameter of Gas Chromatography refers to the variable being measured or analyzed in the process.
The parameter can be the retention time of the analyte, the peak area, or the peak height.
It can also be the resolution between two peaks or the selectivity factor.
The parameter is important in determining the identity and quantity of the analyte in the sample.
It can also be used to optimize the separation conditions for better resolution and sensitivity.
Q7. Which Parameter of HPLC
The parameter of HPLC depends on the type of analysis being performed.
The choice of column and mobile phase affects the separation of analytes
Retention time and peak area are commonly used parameters
Resolution, selectivity, and efficiency are also important parameters
Different parameters may be more important for different types of analysis
For example, quantification may require a different parameter than identification
Top Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month