Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Jun 2022. There was 1 interview round.
Answering questions related to HPLC, impurities, force degradation, solvent classification, and reaction monitoring.
If a column is fitted in the opposite direction in HPLC, it can lead to inaccurate results.
Impurities can be classified as organic, inorganic, or residual solvents.
Force degradation is the process of intentionally subjecting a drug substance to stress conditions to evaluate its stability.
Other methods for...
Top trending discussions
UPLC stands for Ultra Performance Liquid Chromatography.
UPLC is a technique used in analytical chemistry to separate, identify, and quantify components in a mixture.
It is an advanced form of liquid chromatography that utilizes smaller particle sizes and higher pressures for faster and more efficient separations.
UPLC is commonly used in pharmaceutical, environmental, and food analysis.
It offers improved resolution, sens...
I applied via Walk-in and was interviewed before Jun 2021. There were 3 interview rounds.
Trouble shooting during manufacturing involves identifying and resolving issues that arise in the production process.
Identify the problem and its root cause
Gather data and analyze it to determine possible solutions
Implement a solution and monitor its effectiveness
Document the problem and solution for future reference
Collaborate with cross-functional teams to resolve complex issues
I applied via Naukri.com and was interviewed before Jan 2022. There were 2 interview rounds.
I applied via Referral and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Walk-in and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed before Feb 2023. There was 1 interview round.
I applied via Referral and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Referral and was interviewed in Jun 2021. There were 3 interview rounds.
Water content KF reagent is a solution used in Karl Fischer titration to determine water content in a sample.
KF reagent typically consists of iodine, sulfur dioxide, pyridine, and methanol
The formula for KF reagent is usually kept confidential by manufacturers
Different types of KF reagents are available for different types of samples
The water content in a sample is determined by the amount of KF reagent required to rea
based on 2 reviews
Rating in categories
QC Officer
13
salaries
| ₹0 L/yr - ₹0 L/yr |
Officer
13
salaries
| ₹0 L/yr - ₹0 L/yr |
Production Officer
11
salaries
| ₹0 L/yr - ₹0 L/yr |
QA Manager
9
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
7
salaries
| ₹0 L/yr - ₹0 L/yr |
Sun Pharmaceutical Industries
Cipla
Dr. Reddy's
Biocon Limited