Filter interviews by
Calibration is the process of adjusting and verifying the accuracy of a measuring instrument or tool.
Calibration ensures that a measuring instrument or tool provides accurate and reliable results.
It involves comparing the readings of the instrument to a known standard or reference.
Adjustments are made to the instrument until it provides accurate readings.
Calibration is important in industries such as manufacturing, aer...
Calibration ensures accuracy and reliability of instruments and equipment.
Calibration helps to maintain the quality of products and services.
It ensures that measurements are consistent and reliable.
Calibration helps to identify and correct errors in instruments and equipment.
It is necessary for compliance with industry standards and regulations.
Examples of instruments that require calibration include thermometers, pres
Accuracy refers to how close a measurement is to the true value, while acceptance criteria are predetermined standards for what is considered acceptable.
Accuracy is a measure of how close a measurement is to the true value, while acceptance criteria are predetermined standards for what is considered acceptable.
Accuracy is determined by comparing a measurement to a known standard, while acceptance criteria are determine...
Least count is the smallest measurement that can be taken, while resolution is the smallest change that can be detected.
Least count is determined by the instrument's precision and accuracy
Resolution is determined by the number of digits displayed on the instrument
For example, a ruler with a least count of 1 mm can measure up to 1 mm accuracy, while a digital caliper with a resolution of 0.01 mm can detect changes as sm
RTD measures resistance changes with temperature while thermocouple measures voltage changes with temperature.
RTD has a linear relationship between resistance and temperature while thermocouple has a non-linear relationship between voltage and temperature.
RTD is more accurate and stable than thermocouple.
RTD is suitable for precise temperature measurements while thermocouple is suitable for high-temperature measurement...
Pressure gauge measures pressure of gases or liquids, vacuum gauge measures pressure below atmospheric pressure, compound gauge measures both.
Pressure gauge measures pressure of gases or liquids
Vacuum gauge measures pressure below atmospheric pressure
Compound gauge measures both
Pressure gauge is used in applications such as hydraulic systems, air compressors, and refrigeration systems
Vacuum gauge is used in application...
Calibration procedure for pressure gauge involves comparing the gauge readings with a reference standard.
Start by selecting a suitable reference standard with a known accuracy.
Ensure the pressure gauge is clean and in good condition before calibration.
Connect the pressure gauge to the reference standard using appropriate fittings and tubing.
Apply a series of known pressures to the reference standard and record the corr...
Top trending discussions
I applied via Naukri.com and was interviewed in Jun 2020. There were 3 interview rounds.
I applied via Referral and was interviewed in Nov 2020. There were 4 interview rounds.
For loop is used for iterating over a range of values while for each loop is used for iterating over elements of an array.
For loop is used when the number of iterations is known beforehand.
For each loop is used when the number of iterations is not known beforehand.
For loop can be used with any iterable object.
For each loop can only be used with arrays and other iterable objects.
For loop uses an index variable to access...
I applied via Naukri.com and was interviewed in Sep 2020. There were 4 interview rounds.
Integration of sites involves identifying the systems to be integrated, defining the data flow, and implementing the integration process.
Identify the systems to be integrated
Define the data flow between the systems
Choose the appropriate integration method (API, ETL, etc.)
Develop and test the integration process
Deploy the integration process and monitor for errors
Ensure data security and compliance
Provide ongoing suppor
VLAN stands for Virtual Local Area Network and is used to logically separate a network into smaller segments.
VLANs are used to improve network performance and security.
They allow for better network management and easier troubleshooting.
VLANs can be configured on switches and routers.
Examples of VLANs include separating guest and employee networks or separating different departments within a company.
I appeared for an interview before Jun 2016.
I appeared for an interview before Aug 2016.
Some of the top questions asked at the Sri Chakra Scienticfic Sercices interview -
based on 1 interview
Interview experience
based on 26 reviews
Rating in categories
Calibration Engineer
22
salaries
| ₹1.6 L/yr - ₹4.5 L/yr |
Senior Calibration Engineer
10
salaries
| ₹1.8 L/yr - ₹4.5 L/yr |
Executive
4
salaries
| ₹2.2 L/yr - ₹3.5 L/yr |
Instrument Engineer
4
salaries
| ₹2 L/yr - ₹4 L/yr |
Deputy Manager
3
salaries
| ₹6 L/yr - ₹9.3 L/yr |
Marpu Foundation
Huawei Technologies
HCL Infosystems
Z X Learning