Calibration is the process of adjusting and verifying the accuracy of a measuring instrument or tool.
Calibration ensures that a measuring instrument or tool provides accurate and reliable results.
It involves comparing the readings of the instrument to a known standard or reference.
Adjustments are made to the instrument until it provides accurate readings.
Calibration is important in industries such as manufacturing, aer...
Calibration ensures accuracy and reliability of instruments and equipment.
Calibration helps to maintain the quality of products and services.
It ensures that measurements are consistent and reliable.
Calibration helps to identify and correct errors in instruments and equipment.
It is necessary for compliance with industry standards and regulations.
Examples of instruments that require calibration include thermometers, pres
Accuracy refers to how close a measurement is to the true value, while acceptance criteria are predetermined standards for what is considered acceptable.
Accuracy is a measure of how close a measurement is to the true value, while acceptance criteria are predetermined standards for what is considered acceptable.
Accuracy is determined by comparing a measurement to a known standard, while acceptance criteria are determine...
Least count is the smallest measurement that can be taken, while resolution is the smallest change that can be detected.
Least count is determined by the instrument's precision and accuracy
Resolution is determined by the number of digits displayed on the instrument
For example, a ruler with a least count of 1 mm can measure up to 1 mm accuracy, while a digital caliper with a resolution of 0.01 mm can detect changes as sm
RTD measures resistance changes with temperature while thermocouple measures voltage changes with temperature.
RTD has a linear relationship between resistance and temperature while thermocouple has a non-linear relationship between voltage and temperature.
RTD is more accurate and stable than thermocouple.
RTD is suitable for precise temperature measurements while thermocouple is suitable for high-temperature measurement...
Pressure gauge measures pressure of gases or liquids, vacuum gauge measures pressure below atmospheric pressure, compound gauge measures both.
Pressure gauge measures pressure of gases or liquids
Vacuum gauge measures pressure below atmospheric pressure
Compound gauge measures both
Pressure gauge is used in applications such as hydraulic systems, air compressors, and refrigeration systems
Vacuum gauge is used in application...
Calibration procedure for pressure gauge involves comparing the gauge readings with a reference standard.
Start by selecting a suitable reference standard with a known accuracy.
Ensure the pressure gauge is clean and in good condition before calibration.
Connect the pressure gauge to the reference standard using appropriate fittings and tubing.
Apply a series of known pressures to the reference standard and record the corr...
Top trending discussions
I appeared for an interview before May 2016.
I appeared for an interview in Jul 2017.
I appeared for an interview in Jul 2017.
Yes, I am a fresher with no past working experience.
I am a recent graduate looking to gain experience in the field.
I have completed internships or projects during my studies.
I am eager to learn and grow in a professional environment.
I was responsible for conducting market research, creating social media content, and assisting with event planning.
Conducted market research to identify trends and opportunities
Created engaging social media content to increase brand awareness
Assisted in planning and executing events to promote company products/services
I am a recent graduate with a degree in Computer Science and a passion for coding and problem-solving.
Recent graduate with a degree in Computer Science
Passionate about coding and problem-solving
Strong communication and teamwork skills
Experience with programming languages such as Java, Python, and C++
I applied via Approached by Company and was interviewed in Jul 2017. There were 5 interview rounds.
I applied via Other and was interviewed in Jan 2018. There were 5 interview rounds.
I applied via Other and was interviewed in Jan 2018. There were 5 interview rounds.
I appeared for an interview in Mar 2017.
To make the red fishes 98%, 50 fishes have to be removed from the aquarium.
Calculate 1% of 200 fishes, which is 2 fishes.
To make the red fishes 98%, subtract 1% (2 fishes) from 99% (198 fishes).
To find the number of fishes to be removed, divide the difference by 1% (2 fishes).
Therefore, 50 fishes have to be removed to make the red fishes 98%.
posted on 3 May 2017
I appeared for an interview before May 2016.
Some of the top questions asked at the Sri Chakra Scienticfic Sercices interview -
based on 1 interview
Interview experience
based on 26 reviews
Rating in categories
Calibration Engineer
22
salaries
| ₹1.6 L/yr - ₹4.5 L/yr |
Senior Calibration Engineer
10
salaries
| ₹1.8 L/yr - ₹4.5 L/yr |
Executive
4
salaries
| ₹2.2 L/yr - ₹3.5 L/yr |
Instrument Engineer
4
salaries
| ₹2 L/yr - ₹4 L/yr |
Deputy Manager
3
salaries
| ₹6 L/yr - ₹9.3 L/yr |
Marpu Foundation
Huawei Technologies
HCL Infosystems
Z X Learning