Filter interviews by
DG stands for Diesel Generator, used as a backup power source. A transformer is an electrical device that transfers electrical energy between two or more circuits.
DG (Diesel Generator) is a standalone power source that uses diesel fuel to generate electricity during power outages.
Transformers are used to increase or decrease voltage levels in electrical circuits for transmission and distribution.
Transformers can be ste...
I applied via Naukri.com and was interviewed in Jul 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Mar 2024. There were 4 interview rounds.
Transformer work involves installing, maintaining, and repairing electrical transformers.
Installing new transformers in buildings or industrial sites
Performing routine maintenance on transformers to ensure they are functioning properly
Repairing faulty transformers to restore functionality
Testing transformers to ensure they are operating within specifications
Transformer parts include core, windings, insulation, and terminals.
Core: Provides magnetic path for the transformer
Windings: Conductors that carry current and create magnetic field
Insulation: Prevents short circuits between windings
Terminals: Connect transformer to external circuit
Examples: Enameled copper wire for windings, silicon steel for core
Timing joining refers to the process of connecting electrical wires or components based on a specific timing sequence.
Timing joining involves connecting electrical components in a specific order to ensure proper functioning.
It is crucial in complex electrical systems where timing is essential for synchronization.
Examples include connecting wires in a circuit board based on a predetermined timing sequence.
It can also re...
I applied via Referral and was interviewed in Jan 2021. There was 1 interview round.
I appeared for an interview in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
33 kV to 220 SLD refers to a switchgear system for electrical distribution at medium voltage levels.
33 kV to 220 SLD likely refers to a switchgear system designed to handle voltages between 33 kV and 220 kV.
SLD stands for Single Line Diagram, which is a schematic representation of the electrical distribution system.
This switchgear system would be used for distributing electricity from a higher voltage transmission syst...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that operates in the air where the arc is drawn in the air and extinguished using air.
VCB is a type of circuit breaker that operates in a vacuum where the arc is drawn in a vacuum and extinguished using vacuum.
ACBs are commonly used in low voltage applications while VCBs are used in medium voltage applications.
...
I applied via Company Website and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Sep 2023. There was 1 interview round.
I applied via Walk-in and was interviewed in Jan 2023. There were 2 interview rounds.
Transformers are electrical devices that transfer electrical energy between two or more circuits through electromagnetic induction.
Transformers are used to step up or step down voltage levels in electrical power transmission and distribution systems.
They consist of two or more coils of wire, known as windings, which are wound around a core made of magnetic material.
The primary winding is connected to the power source, ...
A fire alarm system is a network of devices that detect and alert people to the presence of fire or smoke.
Fire alarm systems can include smoke detectors, heat detectors, and manual pull stations.
When a device detects smoke or heat, it sends a signal to a control panel, which activates alarms and alerts authorities.
Fire alarm systems are essential for protecting people and property from the dangers of fire.
Examples of p...
based on 1 interview
Interview experience
based on 11 reviews
Rating in categories
Assistant Manager
216
salaries
| ₹2.8 L/yr - ₹10.5 L/yr |
Facility Manager
215
salaries
| ₹4.2 L/yr - ₹13 L/yr |
Facility Executive
207
salaries
| ₹1.8 L/yr - ₹5.4 L/yr |
Shift Engineer
190
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Assistant Facility Manager
172
salaries
| ₹3.3 L/yr - ₹9 L/yr |
Compass Group Support Services
Aramark
CBRE
Cushman & Wakefield