i
Simplex Infrastructures
Filter interviews by
I applied via Company Website and was interviewed before Aug 2020. There were 3 interview rounds.
I have experience in designing and analyzing transmission lines for power distribution.
Designed and analyzed transmission lines for power distribution projects
Performed load flow analysis and short circuit analysis for transmission lines
Experience in using software tools like PLS-CADD and PLS-POLE
Knowledge of industry standards and regulations for transmission line design
Collaborated with cross-functional teams to ensu
Design of foundation is crucial for the stability and safety of any structure.
The type of foundation depends on the soil type and load-bearing capacity.
Factors like building height, weight, and seismic activity must be considered.
Proper drainage and waterproofing must be incorporated.
Foundation design must comply with local building codes and regulations.
Examples of foundation types include shallow, deep, and pile foun
After the shortlisting of CVs, list was sent for those who were eligible for the OT. The online test included aptitude + technical. There were pretty easy to moderate questions but time was less.
I applied via Approached by Company and was interviewed in Oct 2023. There were 3 interview rounds.
I applied via Referral and was interviewed in Jan 2024. There was 1 interview round.
The capacity of Tata Steel's lime plant is yet to be determined.
The capacity of the lime plant is currently unknown and is still to be decided by Tata Steel.
Tata Steel is likely in the process of determining the optimal capacity for their lime plant.
The capacity of the lime plant will depend on various factors such as production requirements, market demand, and technological capabilities.
I applied via Company Website and was interviewed before Jul 2023. There was 1 interview round.
The percentage of steel in a pile varies depending on the type and design of the pile.
The percentage of steel in a pile can range from 0% to over 90%.
The type of pile (e.g. steel, concrete, timber) and its design (e.g. diameter, length, wall thickness) determine the percentage of steel.
Steel piles typically have a higher percentage of steel than other types of piles.
The percentage of steel in a pile can also affect its
Pile built-up above cut off level as per IS code
IS code specifies the maximum allowable pile length above cut off level
Pile length above cut off level should not exceed 3 times the pile diameter
Built-up pile above cut off level can cause structural instability and failure
Vertical tolerance for piles as per IS code
As per IS 2911-1:2010, the vertical tolerance for piles is +/- 25mm
This tolerance is applicable for both driven and cast-in-situ piles
The tolerance is measured at the top of the pile and at intervals of 3m along the length
If the deviation exceeds the tolerance limit, the pile may need to be rejected or remedial measures taken
Pile concrete consumption tolerance depends on various factors.
Pile diameter and length
Concrete mix design
Placement method
Quality control measures
Environmental conditions
Tolerance typically ranges from 5-10% of estimated consumption
Regular monitoring and adjustment of concrete consumption is necessary
Unit weight of steel is 7850 kg/m³
The unit weight of steel is the weight of a specific volume of steel
It is measured in kilograms per cubic meter (kg/m³)
The unit weight of steel is 7850 kg/m³
This value may vary slightly depending on the composition and manufacturing process of the steel
based on 6 reviews
Rating in categories
Assistant Manager
193
salaries
| ₹3.5 L/yr - ₹11.1 L/yr |
Assistant Engineer
164
salaries
| ₹1.8 L/yr - ₹5.1 L/yr |
Assistant Engineer - Civil
161
salaries
| ₹2.6 L/yr - ₹4.7 L/yr |
Project Engineer
145
salaries
| ₹2.9 L/yr - ₹7.8 L/yr |
Deputy Manager
115
salaries
| ₹5.5 L/yr - ₹12.6 L/yr |
Larsen & Toubro Limited
Tata Projects
Hindustan Construction Company
GAMMON INDIA