Filter interviews by
posted on 2 Jan 2025
I was interviewed before Jan 2024.
Calibration process for UV and HPLC instruments involves setting up reference standards, adjusting parameters, and verifying accuracy.
Prepare reference standards for UV and HPLC analysis
Adjust wavelength, detector sensitivity, and flow rate for UV instrument
Run standard solutions to verify accuracy and make necessary adjustments
Perform system suitability tests to ensure instrument performance meets requirements
Reverse phase chromatography uses a non-polar stationary phase and a polar mobile phase, while normal phase chromatography uses a polar stationary phase and a non-polar mobile phase.
Reverse phase chromatography is more commonly used in analytical chemistry for separating non-polar compounds, while normal phase chromatography is used for polar compounds.
In reverse phase chromatography, the more non-polar compounds elute...
I applied via Naukri.com and was interviewed in Oct 2023. There were 2 interview rounds.
CAPA flow involves identifying deviations, investigating root causes, implementing corrective actions, and verifying effectiveness.
Identify the deviation or nonconformance
Investigate the root cause using techniques like 5 Whys, Fishbone diagram
Implement corrective actions to prevent recurrence
Verify the effectiveness of the actions taken
Document the entire CAPA process for future reference
HPLC stands for High Performance Liquid Chromatography, a technique used to separate, identify, and quantify components in a mixture.
HPLC works on the principle of separating components in a mixture based on their interaction with a stationary phase and a mobile phase.
The stationary phase is typically a column packed with a solid material, while the mobile phase is a liquid solvent that carries the sample through the c...
GLP stands for Good Laboratory Practice, a set of principles intended to ensure the quality and integrity of non-clinical laboratory studies.
GLP is a quality system concerned with the organizational process and conditions under which non-clinical health and environmental safety studies are planned, performed, monitored, recorded, archived, and reported.
It ensures that the data generated in such studies are reliable and...
I applied via Naukri.com and was interviewed before Nov 2023. There were 2 interview rounds.
Reagents should be handled with care and proper safety measures to avoid accidents and contamination.
Always wear appropriate personal protective equipment (PPE) such as gloves, goggles, and lab coat.
Read and follow the instructions on the label or Material Safety Data Sheet (MSDS) before using any reagent.
Store reagents properly in designated areas and keep them away from incompatible substances.
Dispose of reagents pro...
posted on 22 May 2022
I applied via Naukri.com and was interviewed before May 2021. There were 3 interview rounds.
Executive Regulatory Affairs
8
salaries
| ₹1.5 L/yr - ₹3.2 L/yr |
QA Officer
8
salaries
| ₹1.2 L/yr - ₹3.1 L/yr |
QC Executive
5
salaries
| ₹2.6 L/yr - ₹3 L/yr |
Production Manager
4
salaries
| ₹4.2 L/yr - ₹6.2 L/yr |
Account Assistant
4
salaries
| ₹1 L/yr - ₹2.8 L/yr |
Baxter International
Fresenius Kabi
Pfizer
GlaxoSmithKline Pharmaceuticals