PWHT requirement is as per code for stress relieving and improving mechanical properties of welded components.
PWHT stands for Post Weld Heat Treatment.
PWHT is required to relieve residual stresses in welded components.
PWHT helps improve mechanical properties such as toughness and ductility.
PWHT requirements are specified in various welding codes and standards such as ASME, AWS, and API.
Impact testing as per code is a method used to determine the toughness and resistance of materials to sudden loading.
Impact testing is conducted to assess the behavior of materials under high-stress conditions.
It helps in determining the ductility, brittleness, and toughness of materials.
Common methods of impact testing include Charpy and Izod tests.
Results of impact testing are compared to specified codes and standard...
Top trending discussions
I applied via Recruitment Consulltant and was interviewed in Aug 2023. There were 2 interview rounds.
Types of compressors include reciprocating, rotary, centrifugal, and axial compressors.
Reciprocating compressors use pistons to compress air or gas.
Rotary compressors use rotating mechanisms such as screws or vanes.
Centrifugal compressors use a rotating impeller to create centrifugal force.
Axial compressors use rotating blades to compress air in a straight line.
Examples include reciprocating air compressors, rotary scr...
The procedure to install centrifugal axial compressors involves proper planning, alignment, assembly, and testing.
Ensure proper foundation is prepared to support the compressor
Align the compressor with the piping system for proper flow
Assemble the compressor components according to manufacturer's instructions
Test the compressor for performance and efficiency before final installation
Types of pumps include centrifugal, positive displacement, and axial flow pumps.
Centrifugal pumps: use centrifugal force to move fluid through the pump
Positive displacement pumps: move fluid by trapping a fixed amount and forcing it through the discharge port
Axial flow pumps: move fluid parallel to the pump shaft
A lifting plan procedure is a detailed plan outlining the steps and precautions to be taken when lifting heavy objects.
Identify the weight and dimensions of the object to be lifted
Determine the appropriate lifting equipment needed
Assess the location and environment for any obstacles or hazards
Assign roles and responsibilities to team members involved in the lift
Communicate clearly and follow the plan step by step
Conduc...
Pumps capacity refers to the maximum flow rate a pump can handle.
Pumps capacity is typically measured in gallons per minute (GPM) or liters per minute (LPM).
It is important to consider the required flow rate when selecting a pump for a specific application.
Factors such as pump size, motor power, and system pressure affect the capacity of a pump.
For example, a centrifugal pump may have a capacity of 500 GPM, while a dia
Methods statement for maintaining rotating and static equipment in mechanical engineering.
Regular inspection and maintenance schedules for both rotating and static equipment
Use of proper lubrication for rotating equipment to prevent wear and tear
Checking alignment and balance of rotating equipment to ensure smooth operation
Testing and calibrating static equipment for accuracy and efficiency
Following manufacturer's guid...
I applied via Recruitment Consulltant and was interviewed in May 2023. There were 2 interview rounds.
posted on 13 Jun 2024
I applied via Naukri.com and was interviewed before Jun 2023. There was 1 interview round.
SFD stands for Shear Force Diagram and BMD stands for Bending Moment Diagram in structural analysis.
SFD shows the variation of shear force along the length of a beam or structure.
BMD shows the variation of bending moment along the length of a beam or structure.
Both diagrams are essential for analyzing the internal forces in a structure.
They are commonly used in civil and mechanical engineering for designing and analyzi...
Thrust forces for beams can be calculated using equations of equilibrium and considering external loads.
Calculate the sum of all external forces acting on the beam.
Determine the direction of the forces (compression or tension) based on the beam's support conditions.
Apply equations of equilibrium to calculate the thrust forces at different points along the beam.
Consider any distributed loads or moments that may affect t...
I applied via Approached by Company and was interviewed in Jun 2022. There were 2 interview rounds.
I applied via LinkedIn and was interviewed in Mar 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed in Aug 2024. There was 1 interview round.
I applied via Naukri.com and was interviewed in May 2023. There were 3 interview rounds.
The number of pressure fire lines can vary depending on the specific requirements of the system and facility.
The number of pressure fire lines is determined by the size and layout of the facility.
Pressure fire lines are typically installed in areas where there is a high risk of fire, such as industrial plants or commercial buildings.
The number of pressure fire lines may also be influenced by local fire safety regulatio...
HVAC requirements refer to the specifications and standards needed for heating, ventilation, and air conditioning systems in a building or facility.
HVAC requirements include proper sizing of equipment to meet the heating and cooling needs of a space
They also involve ensuring proper ventilation to maintain indoor air quality
Compliance with building codes and regulations is essential for HVAC systems
Regular maintenance a...
The question is unclear and does not make sense. It seems to be a typo or a mistake.
The question may be asking about a specific type of equipment or tool, but it is not clear.
It is important to ask for clarification or more information to provide an accurate answer.
Without more context, it is impossible to determine what 'sprlar tipe' refers to.
posted on 7 Feb 2023
I applied via Recruitment Consulltant and was interviewed in Aug 2022. There were 2 interview rounds.
Alignment methods are techniques used to ensure proper positioning and orientation of mechanical components.
Common alignment methods include laser alignment, dial indicator alignment, and straight edge alignment.
Laser alignment uses a laser beam to measure and adjust the alignment of components.
Dial indicator alignment uses a dial gauge to measure the alignment of components.
Straight edge alignment involves using a str...
I applied via Recruitment Consulltant and was interviewed in Aug 2023. There were 2 interview rounds.
Types of compressors include reciprocating, rotary, centrifugal, and axial compressors.
Reciprocating compressors use pistons to compress air or gas.
Rotary compressors use rotating mechanisms such as screws or vanes.
Centrifugal compressors use a rotating impeller to create centrifugal force.
Axial compressors use rotating blades to compress air in a straight line.
Examples include reciprocating air compressors, rotary scr...
The procedure to install centrifugal axial compressors involves proper planning, alignment, assembly, and testing.
Ensure proper foundation is prepared to support the compressor
Align the compressor with the piping system for proper flow
Assemble the compressor components according to manufacturer's instructions
Test the compressor for performance and efficiency before final installation
Types of pumps include centrifugal, positive displacement, and axial flow pumps.
Centrifugal pumps: use centrifugal force to move fluid through the pump
Positive displacement pumps: move fluid by trapping a fixed amount and forcing it through the discharge port
Axial flow pumps: move fluid parallel to the pump shaft
A lifting plan procedure is a detailed plan outlining the steps and precautions to be taken when lifting heavy objects.
Identify the weight and dimensions of the object to be lifted
Determine the appropriate lifting equipment needed
Assess the location and environment for any obstacles or hazards
Assign roles and responsibilities to team members involved in the lift
Communicate clearly and follow the plan step by step
Conduc...
Pumps capacity refers to the maximum flow rate a pump can handle.
Pumps capacity is typically measured in gallons per minute (GPM) or liters per minute (LPM).
It is important to consider the required flow rate when selecting a pump for a specific application.
Factors such as pump size, motor power, and system pressure affect the capacity of a pump.
For example, a centrifugal pump may have a capacity of 500 GPM, while a dia
Methods statement for maintaining rotating and static equipment in mechanical engineering.
Regular inspection and maintenance schedules for both rotating and static equipment
Use of proper lubrication for rotating equipment to prevent wear and tear
Checking alignment and balance of rotating equipment to ensure smooth operation
Testing and calibrating static equipment for accuracy and efficiency
Following manufacturer's guid...
based on 4 reviews
Rating in categories
Senior Engineer
174
salaries
| ₹10.9 L/yr - ₹30.4 L/yr |
Process Engineer
48
salaries
| ₹6 L/yr - ₹12.5 L/yr |
Piping Designer
48
salaries
| ₹4.4 L/yr - ₹16 L/yr |
Piping Engineer
42
salaries
| ₹6 L/yr - ₹20 L/yr |
Instrument Engineer
40
salaries
| ₹6 L/yr - ₹26.5 L/yr |
Larsen & Toubro Limited
Tata Projects
Punj Lloyd
Thermax Limited