Filter interviews by
I applied via Company Website and was interviewed in Jan 2024. There was 1 interview round.
The operation and process of a turbine involves converting the kinetic energy of a fluid or gas into mechanical energy.
Turbines are used in various industries such as power generation, aviation, and oil and gas.
The basic principle of a turbine involves the flow of a fluid or gas through a rotor, which causes the rotor to spin.
The spinning rotor is connected to a shaft, which can be used to drive machinery or generate e...
Top trending discussions
I applied via Company Website and was interviewed in Nov 2020. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Aug 2020. There were 3 interview rounds.
Yes, I have worked on Aspen HYSYS.
I have experience using Aspen HYSYS for process simulation and optimization.
I have used Aspen HYSYS to design and optimize various chemical processes.
I am familiar with the software's capabilities and have used it to model complex systems.
I have also used Aspen HYSYS to perform sensitivity analyses and evaluate different scenarios.
Overall, my experience with Aspen HYSYS has been valuab
Sizing of PSV and vent
PSV (Pressure Safety Valve) should be sized based on the maximum possible flow rate and the set pressure of the system
Vent should be sized based on the maximum possible flow rate and the back pressure of the system
Factors like fluid properties, temperature, and pressure drop should also be considered while sizing PSV and vent
Proper sizing of PSV and vent is crucial for ensuring the safety of the s
A P&ID of a scrubber is a diagram that shows the process flow and equipment involved in removing pollutants from industrial exhaust gases.
The P&ID should include the inlet and outlet streams, as well as the scrubbing liquid and any necessary pumps or valves.
The scrubber itself should be clearly labeled and include details such as the type of scrubbing media used (e.g. water, chemicals) and any associated instrumentatio...
I applied via Referral and was interviewed before May 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before May 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed before Oct 2020. There were 5 interview rounds.
I applied via Naukri.com and was interviewed in Dec 2020. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Jan 2018. There were 5 interview rounds.
I applied via Company Website and was interviewed before Mar 2020. There was 1 interview round.
I applied via Walk-in and was interviewed before Feb 2020. There was 1 interview round.
DB1701 and HP5 columns are commonly used in chromatography due to their high thermal stability and wide range of applications.
DB1701 and HP5 columns are both stationary phases used in gas chromatography.
DB1701 column is a non-polar phase, while HP5 column is a polar phase.
DB1701 column is commonly used for analyzing volatile organic compounds (VOCs) in environmental samples.
HP5 column is often used for analyzing polar ...
based on 1 interview
Interview experience
Senior Engineer
21
salaries
| ₹8.4 L/yr - ₹20 L/yr |
Executive Accountant
17
salaries
| ₹0.8 L/yr - ₹3 L/yr |
Apprentice Trainee
17
salaries
| ₹0.6 L/yr - ₹2.5 L/yr |
Deputy Manager
15
salaries
| ₹12 L/yr - ₹22 L/yr |
Plant Operator
15
salaries
| ₹0.9 L/yr - ₹4.8 L/yr |
Aarti Industries
UPL
Coromandel International
PI Industries