Filter interviews by
I applied via Walk-in and was interviewed before Jan 2024. There was 1 interview round.
Top trending discussions
I applied via Job Portal and was interviewed in Oct 2024. There were 2 interview rounds.
I applied via Company Website and was interviewed in Apr 2024. There was 1 interview round.
PLC stands for Programmable Logic Controller, used in industrial automation to control machinery and processes.
PLC is a digital computer used for automation of electromechanical processes.
It uses a programmable memory to store instructions and specific functions.
PLCs are commonly used in manufacturing plants, assembly lines, and other industrial settings.
They can be programmed using ladder logic, function block diagram...
Different types of communication cables used in the electrical engineering industry include coaxial cables, twisted pair cables, and fiber optic cables.
Coaxial cables: used for high-frequency transmission and commonly used in cable television and computer networks.
Twisted pair cables: consists of pairs of insulated copper wires twisted together to reduce electromagnetic interference, commonly used in Ethernet networks.
...
Single mode fiber optic cable has a smaller core size and allows only one mode of light to propagate, while multimode fiber optic cable has a larger core size and allows multiple modes of light to propagate.
Single mode fiber optic cable has a core size of 8-10 microns, while multimode fiber optic cable has a core size of 50-62.5 microns.
Single mode fiber optic cable provides higher bandwidth and longer transmission dis...
Types of transformers include step-up, step-down, isolation, autotransformer, and distribution transformers.
Step-up transformer increases voltage output
Step-down transformer decreases voltage output
Isolation transformer provides electrical isolation between primary and secondary windings
Autotransformer has a single winding with multiple taps for different voltage levels
Distribution transformer is used to distribute pow
Protection system for transformers includes Buchholz relay, differential protection, overcurrent protection, and temperature monitoring.
Buchholz relay detects internal faults like gas accumulation or oil leakage
Differential protection compares currents entering and leaving the transformer to detect faults
Overcurrent protection safeguards against excessive current flow
Temperature monitoring ensures the transformer opera
Regular maintenance of transformers and motors is crucial for ensuring optimal performance and preventing breakdowns.
Regularly inspecting for signs of wear and tear
Checking and replacing worn out parts such as brushes and bearings
Testing insulation resistance
Cleaning and lubricating moving parts
Monitoring temperature and vibration levels
Following manufacturer's maintenance guidelines
Keeping records of maintenance activ
Differential protection of transformer ensures that any internal fault is quickly detected and isolated to prevent damage.
Differential protection compares the current entering and leaving the transformer windings. If there is a difference, it indicates a fault.
The relay used for differential protection operates when the difference in current exceeds a set threshold.
This protection scheme is effective in detecting inter...
Ten delta test is a method used to determine the phase relationship between the primary and secondary windings of a transformer.
Ten delta test involves injecting a low voltage signal into the primary winding and measuring the corresponding output in the secondary winding.
The test helps in identifying any phase shift or angular displacement between the primary and secondary windings.
It is important for ensuring the prop...
I applied via AmbitionBox and was interviewed in Aug 2024. There were 2 interview rounds.
I applied via Campus Placement and was interviewed in Feb 2024. There were 3 interview rounds.
Some questions time,speed,distance ,averages,technical questions related to your branch
I am a dedicated Electrical Engineer with a passion for problem-solving and innovation.
Graduated with a degree in Electrical Engineering from XYZ University
Experienced in designing and implementing electrical systems for commercial buildings
Proficient in using CAD software for schematic design
Strong analytical skills and attention to detail
Completed internships at ABC Company and gained hands-on experience
I celebrated Holi with my family and friends by playing with colors and enjoying traditional food. I know that Cyient is a global engineering and technology solutions company.
Celebrated Holi with family and friends
Played with colors and enjoyed traditional food
Cyient is a global engineering and technology solutions company
I applied via Company Website and was interviewed in Oct 2023. There were 2 interview rounds.
I was interviewed before Feb 2024.
The subjects of study include Physics, Chemistry, and Mathematics.
Basic appti ques were asked
Transformer types include step-up, step-down, isolation, autotransformer, and instrument transformer.
Step-up transformer increases voltage while decreasing current
Step-down transformer decreases voltage while increasing current
Isolation transformer separates primary and secondary windings
Autotransformer has a single winding with multiple taps for voltage adjustment
Instrument transformer is used for measuring current or
Motors are devices that convert electrical energy into mechanical energy. There are various types of motors.
DC motors: used in appliances, toys, and automobiles
AC motors: used in industrial machinery and household appliances
Stepper motors: used in robotics and automation
Servo motors: used in precision control applications
Brushless motors: used in drones and electric vehicles
posted on 17 Feb 2023
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Sales Officer
8
salaries
| ₹4 L/yr - ₹6.2 L/yr |
Maintenance Supervisor
7
salaries
| ₹1 L/yr - ₹2.5 L/yr |
Senior Officer
7
salaries
| ₹3.2 L/yr - ₹6.2 L/yr |
Safety Officer
5
salaries
| ₹3 L/yr - ₹3.6 L/yr |
Deputy Engineer
5
salaries
| ₹4.5 L/yr - ₹5.4 L/yr |
Arvind Group
Welspun Living Limited
Vardhman Fabrics
Indo Count Industries