Filter interviews by
I applied via Walk-in and was interviewed before Oct 2020. There were 3 interview rounds.
Top trending discussions
posted on 14 Dec 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 4 interview rounds.
I worked at XYZ Company, a manufacturing firm specializing in automotive components.
Responsible for conducting preventive maintenance on production machinery
Troubleshoot and repair mechanical issues on equipment
Collaborated with production team to ensure minimal downtime
Implemented new maintenance procedures to improve efficiency
Yes, I am willing to relocate or commute daily for the job.
I am open to relocating for the right opportunity.
I am willing to commute daily if necessary.
I understand the importance of flexibility in the job market.
I have handled a wide range of equipment in my role as a Mechanical Maintenance Engineer.
Pumps and compressors
Conveyors and material handling equipment
Boilers and heat exchangers
HVAC systems
Generators and power distribution systems
Machine tools and production equipment
Hydraulic and pneumatic systems
Crane and lifting equipment
Instrumentation and control systems
When opening a centrifugal pump, it is important to follow proper procedures to ensure safety and prevent damage.
Before opening the pump, ensure that it is isolated from the power source and all pressure has been relieved.
Inspect the pump for any signs of damage or wear, such as leaks, cracks, or excessive vibration.
Check the pump's impeller and casing for any debris or blockages that may affect its performance.
If nece...
Vacuum is created in a steam ejector through the principle of jet propulsion.
Steam ejectors use high-pressure steam to create a low-pressure environment.
The steam enters the nozzle of the ejector and expands, creating a high-velocity jet.
This high-velocity jet entrains and compresses the surrounding gas or vapor, reducing its pressure.
The entrained gas or vapor is then discharged through the diffuser, creating a vacuum...
1 torr is equal to 0.03937 mm of Hg.
1 torr is a unit of pressure equal to 1/760th of standard atmospheric pressure.
mm of Hg is a unit of pressure commonly used in vacuum systems.
To convert torr to mm of Hg, multiply by 0.03937.
Example: 1 torr = 1 * 0.03937 mm of Hg = 0.03937 mm of Hg.
759 mm of hg is a unit of pressure measurement.
mm of hg is a common unit used to measure pressure.
759 mm of hg is equivalent to 1012.8 millibars or 14.1 pounds per square inch (psi).
It is often used in meteorology to measure atmospheric pressure.
In mechanical maintenance, it can be used to monitor pressure in systems or equipment.
For example, if a pressure gauge reads 759 mm of hg, it indicates the pressure exerted by
In a clean room area, parameters observed include air quality, temperature, humidity, particle count, and pressure differentials.
Air quality is monitored to ensure low levels of contaminants.
Temperature is controlled to maintain a stable environment for sensitive equipment.
Humidity levels are regulated to prevent moisture-related issues.
Particle count is measured to ensure cleanliness and prevent contamination.
Pressure...
Mechanical seal types include cartridge seals, component seals, and bellows seals.
Cartridge seals are pre-assembled units that are easy to install and replace.
Component seals are made up of separate rotating and stationary parts.
Bellows seals use a flexible metal bellows to provide a dynamic seal.
posted on 26 Jun 2023
I applied via Naukri.com and was interviewed before Jun 2022. There were 3 interview rounds.
posted on 14 Jun 2024
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.
Analyzed thermal performance of parabolic solar collector for M.Tech project
Researched various materials for collector construction
Conducted experiments to measure heat transfer efficiency
Analyzed data to optimize collector design
Compared results with theoretical models
Presented findings in a detailed report
Energy management of a plant involves optimizing energy usage to reduce costs and environmental impact.
Implementing energy-efficient technologies and practices
Monitoring energy consumption and identifying areas for improvement
Utilizing renewable energy sources where possible
Regular maintenance of equipment to ensure optimal performance
Training staff on energy conservation practices
posted on 3 Jul 2024
posted on 10 Aug 2023
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
posted on 8 Aug 2022
posted on 29 Apr 2022
I applied via Naukri.com and was interviewed in Oct 2021. There were 2 interview rounds.
Calculating cooling tower TR, boiler efficiency, and types and capacity of chilling plant compressors.
Cooling tower TR can be calculated using the formula: TR = (500 x GPM x Delta T)/12000
Boiler efficiency can be calculated using the formula: Efficiency = (Output/Input) x 100
Types of compressors include reciprocating, rotary screw, centrifugal, and scroll.
Capacity of compressors is measured in tons of refrigeration (TR...
Answering questions related to Maintenance Engineer interview.
Types of boilers include fire tube, water tube, and electric boilers.
Chilling plant capacity can be calculated by multiplying the flow rate by the temperature difference.
Colour coding in industry is used to identify pipes, wires, and equipment based on their function or contents.
Schedule maintenance is planned maintenance that is performed at regular interva...
posted on 5 Sep 2021
I applied via Naukri.com and was interviewed in Mar 2021. There were 3 interview rounds.
based on 3 reviews
Rating in categories
Production Supervisor
750
salaries
| ₹1.8 L/yr - ₹9.6 L/yr |
Executive
254
salaries
| ₹3.5 L/yr - ₹11.8 L/yr |
Supervisor
226
salaries
| ₹2.2 L/yr - ₹9 L/yr |
Research Scientist
213
salaries
| ₹5 L/yr - ₹12.1 L/yr |
Assistant Manager
144
salaries
| ₹6.7 L/yr - ₹22.5 L/yr |
Bayer Crop Science Vegetable Seeds
UPL
Syngenta
Coromandel International