Neyveli Uttar Pradesh Power
Aspire Consultancy Services Interview Questions and Answers
Q1. Which insulin can be given I. V route?
Regular insulin is the only type of insulin that can be given via the intravenous (IV) route.
Regular insulin is the only insulin that is soluble and stable enough to be administered intravenously.
Other types of insulin, such as rapid-acting, intermediate-acting, and long-acting insulins, are not suitable for IV administration.
Regular insulin is commonly used in emergency situations or in hospital settings when immediate blood sugar control is required.
Examples of regular insu...read more
Q2. What is the management of shock?
Management of shock involves identifying the cause, providing fluid resuscitation, administering medications, and addressing underlying issues.
Identify and treat the underlying cause of shock
Provide fluid resuscitation to restore blood volume
Administer medications to support blood pressure and cardiac function
Address underlying issues such as infection or bleeding
Monitor vital signs and adjust treatment accordingly
Q3. Management and diagnosis of mi??
Management and diagnosis of MI involves prompt recognition, risk stratification, and timely reperfusion therapy.
Immediate assessment of symptoms and ECG findings
Risk stratification using clinical and imaging tools
Prompt initiation of reperfusion therapy, either pharmacological or mechanical
Secondary prevention measures to prevent future events
Close monitoring and management of complications
Q4. Management of acute asthma?
Management of acute asthma involves prompt assessment, bronchodilator therapy, and close monitoring.
Assess the severity of the asthma attack using clinical features and peak expiratory flow rate (PEFR)
Administer short-acting beta-agonist (SABA) bronchodilators like albuterol via inhalation
Consider adding ipratropium bromide to SABA in severe cases
Systemic corticosteroids (e.g., prednisone) may be necessary for moderate to severe exacerbations
Supplemental oxygen therapy should...read more
Q5. Types of transmitter, named them?
Transmitters are devices used to measure and transmit data. They can be classified into various types based on their functionality and application.
Pressure transmitters - used to measure and transmit pressure readings
Temperature transmitters - used to measure and transmit temperature readings
Level transmitters - used to measure and transmit liquid or gas levels
Flow transmitters - used to measure and transmit flow rates
Humidity transmitters - used to measure and transmit humid...read more
Q6. Type of between gauges ?
There are various types of gauges used for calibration such as plug gauges, ring gauges, snap gauges, bore gauges, etc.
Plug gauges are used to check the diameter of holes
Ring gauges are used to check the diameter of shafts
Snap gauges are used to check the thickness of objects
Bore gauges are used to check the diameter of cylinders
Thread gauges are used to check the pitch and diameter of threads
Q7. Difference between RTD and TC
RTD stands for Resistance Temperature Detector and TC stands for Thermocouple. They are both temperature sensors but differ in their principles of operation.
RTD measures temperature by correlating the resistance of a metal with temperature.
TC measures temperature based on the voltage generated by the junction of two dissimilar metals.
RTD provides higher accuracy and stability compared to TC.
RTD has a linear relationship between resistance and temperature, while TC has a non-l...read more