I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
Baud rate is the rate at which data is transmitted over a communication channel.
Baud rate is measured in bits per second (bps).
Higher baud rates allow for faster data transmission.
Baud rate must be set the same on both ends of the communication channel.
Incorrect baud rate settings can result in data corruption or loss.
Examples of communication channels that use baud rate include UART, SPI, and I2C.
I2C is a serial communication protocol used to connect multiple devices with two wires. Pull-up resistors are necessary for proper communication.
I2C uses a master-slave architecture where the master initiates communication.
Each device on the bus has a unique address assigned to it.
Data is transmitted in packets with a start and stop bit.
Pull-up resistors are necessary to ensure proper voltage levels on the bus.
The valu...
I applied via Referral and was interviewed in Oct 2023. There was 1 interview round.
Design engineers must adhere to applicable standards to ensure quality and safety of products.
Design engineers should be familiar with industry-specific standards such as ISO 9001, ASME Y14.5, and ASTM.
Adherence to standards ensures product quality, safety, and compliance with regulations.
Standards may vary depending on the industry and type of product being designed.
Regular updates and training on new standards are es
I applied via Naukri.com and was interviewed in Dec 2023. There was 1 interview round.
I would rate myself as highly proficient in AutoCAD.
I have extensive experience using AutoCAD in various design projects.
I am skilled in creating detailed 2D and 3D models using AutoCAD.
I am familiar with advanced features and tools in AutoCAD, such as parametric modeling and rendering.
I have successfully completed complex design projects using AutoCAD, meeting all requirements and deadlines.
I continuously update my kn...
The difference between == and === is that == compares the values of two variables, while === compares both the values and the data types.
The == operator performs type coercion, meaning it converts the operands to a common type before comparison.
The === operator does not perform type coercion and requires both the values and the data types to be the same for a true comparison.
For example, 1 == '1' returns true because t...
based on 1 interview
Interview experience
Assistant Project Manager
5
salaries
| ₹0 L/yr - ₹0 L/yr |
HR Business Partner
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Field Service Engineer
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Design Engineer
3
salaries
| ₹0 L/yr - ₹0 L/yr |
Customer Service Executive
3
salaries
| ₹0 L/yr - ₹0 L/yr |
Legrand
Siemens
Honeywell Automation
ABB