Filter interviews by
A pool fire is a fire burning on the surface of a liquid, while a jet fire is a flame from a high-pressure gas release.
Pool fire occurs when flammable liquids ignite on a surface, creating a large, stable flame.
Jet fire results from the release of flammable gas under high pressure, producing a directed flame.
Example of pool fire: A gasoline spill igniting on a parking lot.
Example of jet fire: A gas line rupture ca...
Implemented a new monitoring system that increased efficiency by 20% in my previous industry.
Implemented new monitoring system
Increased efficiency by 20%
Received recognition for the achievement
I have experience with start up and shut down procedures in previous roles.
Start up procedure involves checking equipment readiness and initiating the system.
Shut down procedure includes safely powering down equipment and securing the area.
Following standard operating procedures is crucial for both start up and shut down processes.
Example: In my previous role as a DCS operator, I followed a detailed checklist for ...
MIG welding is a process that uses a continuous solid wire electrode and shielding gas to join two metal pieces together.
MIG welding stands for Metal Inert Gas welding.
The purpose of MIG welding is to create a strong and durable bond between metal pieces.
It is commonly used in industries such as automotive, construction, and manufacturing.
MIG welding is known for its versatility and ability to weld various types o...
The types of MIG welding include short circuit transfer, globular transfer, spray transfer, and pulsed spray transfer.
Short circuit transfer: Uses low voltage and creates a short circuit between the electrode and the workpiece.
Globular transfer: Involves larger droplets of molten metal being transferred across the arc.
Spray transfer: Uses high voltage to create a spray of tiny molten droplets.
Pulsed spray transfer...
Glycol is used in the impulse tube of level transmitter to prevent freezing and ensure accurate measurement.
Glycol has a lower freezing point than water, preventing the impulse tube from freezing in cold temperatures.
Glycol also helps to prevent bacterial growth and corrosion in the impulse tube.
The use of glycol ensures accurate measurement by maintaining a consistent fluid density in the impulse tube.
Common glyc...
I have worked on various software including Aspen HYSYS, MATLAB, and AutoCAD.
Proficient in Aspen HYSYS for process simulation and optimization
Experience in MATLAB for data analysis and modeling
Skilled in AutoCAD for process flow diagrams and P&IDs
Field Commissioning Specialist is responsible for ensuring that equipment and systems are installed, tested, and functioning properly.
The specialist oversees the commissioning process from start to finish
They work closely with engineers, contractors, and clients to ensure that all requirements are met
They perform tests and inspections to ensure that equipment and systems are functioning properly
They troubleshoot a...
To check level transmitter at 0%, disconnect the transmitter from the process and verify the output signal is at 4mA.
Disconnect the transmitter from the process
Verify the output signal is at 4mA
Check the wiring and connections
Ensure the transmitter is properly configured for 0% level
Perform a loop check to confirm the transmitter is functioning correctly
Boiler commission activity refers to the process of testing and verifying the functionality of a newly installed boiler.
Boiler commissioning involves a series of tests to ensure that the boiler is safe, efficient, and meets regulatory standards.
Tests may include checking the fuel and water supply systems, verifying the control system, and testing safety features.
Commissioning also involves training operators and d...
I applied via Recruitment Consulltant and was interviewed in Oct 2023. There were 2 interview rounds.
Boiler process involves heating water to generate steam for various applications. Instrumentation and control valves are crucial for maintaining optimal operation.
Boiler process involves heating water to produce steam, which is used for heating, power generation, and other industrial processes.
Instrumentation in boiler systems includes sensors for measuring temperature, pressure, and flow rates to ensure safe and effic...
I appeared for an interview before Mar 2024, where I was asked the following questions.
I applied via Recruitment Consulltant
I have experience with start up and shut down procedures in previous roles.
Follow standard operating procedures for start up and shut down processes
Ensure all equipment is properly functioning before starting up or shutting down
Monitor gauges and indicators during start up and shut down to ensure smooth operation
Communicate with team members to coordinate start up and shut down procedures
Document any issues or abnormal...
I appeared for an interview before Apr 2024, where I was asked the following questions.
A pool fire is a fire burning on the surface of a liquid, while a jet fire is a flame from a high-pressure gas release.
Pool fire occurs when flammable liquids ignite on a surface, creating a large, stable flame.
Jet fire results from the release of flammable gas under high pressure, producing a directed flame.
Example of pool fire: A gasoline spill igniting on a parking lot.
Example of jet fire: A gas line rupture causing...
BA stands for Breathing Apparatus, essential for firefighters in smoke-filled environments.
BA is used to provide breathable air in hazardous conditions.
It consists of a tank, regulator, and mask.
Example: Firefighters use BA during structure fires to prevent smoke inhalation.
Regular training is required to ensure proper use and maintenance.
Confined space equipment ensures safety during rescue and work in hazardous, enclosed environments.
Personal Protective Equipment (PPE): Includes helmets, gloves, and respirators.
Ventilation Equipment: Fans and blowers to ensure fresh air circulation.
Monitoring Devices: Gas detectors to identify harmful gases like CO or H2S.
Rescue Equipment: Harnesses, ropes, and stretchers for safe extraction.
Lighting: Portable lights ...
Backdraft is a dangerous fire phenomenon occurring when oxygen is suddenly introduced to a smoldering fire, causing explosive combustion.
Occurs when a fire is starved of oxygen and produces combustible gases.
When a door or window is opened, fresh oxygen can ignite these gases.
Can result in explosive flames and rapid fire spread.
Example: A fire in a sealed room that suddenly ignites when a firefighter opens a door.
Heat transmission occurs through conduction, convection, and radiation, affecting firefighting strategies and safety.
Conduction: Heat transfer through direct contact, e.g., a firefighter touching a hot surface.
Convection: Heat transfer through fluid movement, e.g., hot air rising in a burning building.
Radiation: Heat transfer through electromagnetic waves, e.g., feeling heat from a fire without direct contact.
Understan...
I applied via Recruitment Consulltant and was interviewed before Aug 2022. There were 2 interview rounds.
I have experience with start up and shut down procedures in previous roles.
Start up procedure involves checking equipment readiness and initiating the system.
Shut down procedure includes safely powering down equipment and securing the area.
Following standard operating procedures is crucial for both start up and shut down processes.
Example: In my previous role as a DCS operator, I followed a detailed checklist for start...
Implemented a new monitoring system that increased efficiency by 20% in my previous industry.
Implemented new monitoring system
Increased efficiency by 20%
Received recognition for the achievement
I applied via Recruitment Consulltant and was interviewed in Jul 2022. There was 1 interview round.
The heater startup sequence involves several steps to ensure safe and efficient operation.
Check the fuel supply and ignition source
Open the fuel valve and ignite the burner
Monitor the temperature and adjust as necessary
Ensure proper ventilation and safety measures
Shutdown the heater properly when finished
Glycol is used in the impulse tube of level transmitter to prevent freezing and ensure accurate measurement.
Glycol has a lower freezing point than water, preventing the impulse tube from freezing in cold temperatures.
Glycol also helps to prevent bacterial growth and corrosion in the impulse tube.
The use of glycol ensures accurate measurement by maintaining a consistent fluid density in the impulse tube.
Common glycols u...
I have worked on various software including Aspen HYSYS, MATLAB, and AutoCAD.
Proficient in Aspen HYSYS for process simulation and optimization
Experience in MATLAB for data analysis and modeling
Skilled in AutoCAD for process flow diagrams and P&IDs
I applied via Recruitment Consulltant and was interviewed before Dec 2022. There were 2 interview rounds.
Field Commissioning Specialist is responsible for ensuring that equipment and systems are installed, tested, and functioning properly.
The specialist oversees the commissioning process from start to finish
They work closely with engineers, contractors, and clients to ensure that all requirements are met
They perform tests and inspections to ensure that equipment and systems are functioning properly
They troubleshoot any is...
I applied via Recruitment Consultant and was interviewed in Jul 2021. There were 3 interview rounds.
To check level transmitter at 0%, disconnect the transmitter from the process and verify the output signal is at 4mA.
Disconnect the transmitter from the process
Verify the output signal is at 4mA
Check the wiring and connections
Ensure the transmitter is properly configured for 0% level
Perform a loop check to confirm the transmitter is functioning correctly
Cause and effect refers to the relationship between an event (the cause) and a second event (the effect), where the second event is a result of the first.
Cause and effect is a fundamental concept in science and philosophy.
It is used to explain how one event leads to another.
Examples include: smoking causes lung cancer, lack of exercise causes obesity, and studying leads to better grades.
Identifying the cause of a probl...
Top trending discussions
based on 9 interview experiences
Difficulty level
Duration
based on 95 reviews
Rating in categories
Field Operator
48
salaries
| ₹11.9 L/yr - ₹40.3 L/yr |
Field Commissioning Specialist
31
salaries
| ₹24 L/yr - ₹31.5 L/yr |
Commissioning Specialist
17
salaries
| ₹16.6 L/yr - ₹42 L/yr |
DCS Commissioning Specialist
16
salaries
| ₹27.2 L/yr - ₹36 L/yr |
Instrumentation Technician
12
salaries
| ₹11.6 L/yr - ₹25.5 L/yr |
TCS
Accenture
Wipro
Cognizant