Q1. Which side connected to OLTC in transformer
The OLTC (On-Load Tap Changer) in a transformer is typically connected to the high voltage side.
OLTC is connected to the high voltage winding of the transformer
It allows for tap changing while the transformer is energized
The low voltage side remains fixed while the high voltage side can be adjusted
Q2. Why use in ten delta test in transformer ?
Ten delta test is used to detect winding deformation and shorted turns in transformer.
Detects winding deformation and shorted turns
Helps in identifying internal faults
Used for routine maintenance and troubleshooting
Q3. Why use in bukolze relay
Bukolze relays are used in electrical engineering for their high reliability and ability to handle high voltage and current.
Bukolze relays are known for their robustness and durability.
They are commonly used in power distribution systems and industrial applications.
These relays can handle high voltage and current levels, making them suitable for heavy-duty operations.
They provide reliable switching and protection in electrical circuits.
Bukolze relays are designed to withstand...read more
Q4. UV Coil give a protection over voltage and under voltage
UV Coil provides protection against over voltage and under voltage.
UV Coil is a device used in electrical systems to protect against voltage fluctuations.
It monitors the voltage levels and activates when the voltage exceeds or falls below the specified limits.
When the voltage exceeds the upper limit, the UV Coil disconnects the power supply to prevent damage to the equipment.
Similarly, when the voltage falls below the lower limit, the UV Coil interrupts the power supply to av...read more
Q5. Why use explolation went in tranformer ?
Explosion vent in transformer is used for safety purposes.
It helps to release pressure build-up inside the transformer due to internal faults or external factors.
It prevents the transformer from exploding and causing damage to the surrounding area.
The vent is designed to open at a specific pressure level to ensure safe release of gases.
It is a mandatory safety feature in transformers as per industry standards.
Examples of external factors that can cause pressure build-up inclu...read more
Q6. OLTC always connected in HT voltage side
Yes, OLTC is always connected in the HT voltage side.
OLTC stands for On-Load Tap Changer.
It is a device used in electrical power transformers to regulate the voltage level.
OLTC is typically connected on the high voltage (HT) side of the transformer.
It allows for tap changing while the transformer is energized and under load.
By changing the tap position, the OLTC can adjust the transformer's output voltage.
This helps to compensate for variations in the input voltage or load co...read more
Q7. Why use in star delta
Star delta is used in electrical engineering to reduce starting current and protect motors.
Star delta connection is used for induction motors.
It reduces the starting current by a factor of √3.
It helps in reducing voltage drop during motor starting.
It protects the motor from excessive current and overheating.
It is commonly used in applications where the motor needs to start with a low current.
Q8. What is the working of UV coil
UV coil is a component used in HVAC systems to disinfect air by emitting ultraviolet light.
UV coil is installed in the air handling unit of HVAC systems.
It emits ultraviolet light to kill or deactivate microorganisms like bacteria, viruses, and mold spores.
UV light damages the DNA and RNA of these microorganisms, preventing them from reproducing.
UV coil helps improve indoor air quality by reducing the presence of harmful pathogens.
Regular maintenance and cleaning of UV coil a...read more
Q9. Why used star delta starter
Star delta starter is used to reduce the starting current of induction motors.
Reduces the starting current of induction motors
Prevents excessive voltage drop in the power supply
Protects the motor windings from overheating
Allows for smooth and controlled motor starting
Commonly used in applications where high starting torque is not required