Gujarat Narmada Valley Fertilizers & Chemicals
10+ Accenture Interview Questions and Answers
Q1. What are the type of column and in what scenarios you would select that colum?
Types of columns and their selection criteria for engineering projects.
Types of columns include steel, concrete, timber, and composite columns.
Selection criteria depend on factors such as load capacity, material availability, and cost.
For example, steel columns are often used in high-rise buildings due to their strength and durability.
Concrete columns are preferred for their fire resistance and low maintenance.
Timber columns are commonly used in residential construction for t...read more
Q2. What is joule Thomasan coefficient in cryogenic technology?
Joule-Thomson coefficient is the change in temperature of a gas when it is allowed to expand or contract without any work being done.
It is a measure of the rate of change of temperature with respect to pressure at constant enthalpy.
It is used in cryogenic technology to determine the cooling effect of a gas when it expands through a valve or porous plug.
The coefficient can be positive or negative depending on the gas and the temperature and pressure conditions.
For example, hel...read more
Q3. Design of column, design of heat exchanger, design of centrifugal pump?
Design of column, heat exchanger, and centrifugal pump involves various factors such as fluid properties, operating conditions, and material selection.
Column design involves determining the column diameter, height, and packing material based on the required separation efficiency and pressure drop.
Heat exchanger design involves selecting the appropriate type of exchanger, determining the heat transfer area, and selecting the appropriate fluid flow arrangement.
Centrifugal pump ...read more
Q4. What is shutoff pressure in pump?
Shutoff pressure is the maximum pressure a pump can generate when it is not pumping any fluid.
Shutoff pressure is also known as deadhead pressure.
It is the pressure at which the pump can no longer move any fluid.
It is important to know the shutoff pressure to prevent damage to the pump and system.
For example, if the shutoff pressure of a pump is 100 psi, the pump will stop generating flow when the pressure in the system reaches 100 psi.
Q5. Types of pump, compressors?
Pumps: centrifugal, positive displacement, axial flow. Compressors: reciprocating, rotary, centrifugal.
Centrifugal pumps use a rotating impeller to move fluid.
Positive displacement pumps move fluid by trapping a fixed amount and forcing it through the discharge.
Axial flow pumps use propellers to move fluid.
Reciprocating compressors use pistons to compress gas.
Rotary compressors use rotating screws or vanes to compress gas.
Centrifugal compressors use a rotating impeller to com...read more
Q6. Refrigeration cycle?
Refrigeration cycle is a thermodynamic process used in refrigerators and air conditioners to transfer heat from a low-temperature region to a high-temperature region.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant is compressed by the compressor and then condensed in the condenser, releasing heat to the surroundings.
The high-pressure liquid refrigerant then passes through the expansion valve, where it undergoe...read more
Q7. Characteristic curve of pump?
Characteristic curve of a pump shows the relationship between flow rate and head developed by the pump.
It is a graph plotted between flow rate and head developed by the pump.
It helps in determining the efficiency of the pump.
The curve is obtained by conducting experiments on the pump.
It is used to select the appropriate pump for a given application.
Q8. How to reduce hospital budget?
Reducing hospital budget can be achieved through various measures such as optimizing staff and supply utilization, negotiating with vendors, and implementing cost-saving initiatives.
Optimize staff and supply utilization by reducing waste and unnecessary expenses
Negotiate with vendors to get better prices for medical supplies and equipment
Implement cost-saving initiatives such as energy-efficient lighting and equipment, and reducing readmissions
Consider outsourcing non-core fu...read more
Q9. Types of breather in transforner
Breathers in transformers are used to prevent moisture and dust from entering the transformer tank.
Silica gel breathers absorb moisture from the air inside the transformer tank.
Magnetic oil level indicators prevent dust and moisture from entering the transformer tank.
Desiccant breathers also help in keeping the transformer tank dry and free from contaminants.
Q10. Ups scheme drawing and explanation
UPS scheme drawing and explanation involves understanding the Uninterruptible Power Supply system and its components.
UPS system provides backup power during electrical outages or fluctuations.
Components include battery, inverter, rectifier, and bypass switch.
UPS scheme drawing shows how these components are connected and function together.
Example: UPS scheme drawing may include arrows showing the flow of electricity from the battery to the inverter during a power outage.