I applied via Walk-in and was interviewed in Jul 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed in Apr 2021. There were 3 interview rounds.
Previous site infrastructure included data centers, networking equipment, servers, and storage systems.
Data centers were located in multiple regions for redundancy.
Networking equipment included routers, switches, and firewalls.
Servers were a mix of physical and virtual machines.
Storage systems used SAN and NAS technologies.
Backup and disaster recovery plans were in place.
Monitoring tools were used to track performance
Multiple scenarios of UPS DG CHILLER FAILURES
I appeared for an interview in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
I applied via Company Website and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
33 kV to 220 SLD refers to a switchgear system for electrical distribution at medium voltage levels.
33 kV to 220 SLD likely refers to a switchgear system designed to handle voltages between 33 kV and 220 kV.
SLD stands for Single Line Diagram, which is a schematic representation of the electrical distribution system.
This switchgear system would be used for distributing electricity from a higher voltage transmission syst...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that operates in the air where the arc is drawn in the air and extinguished using air.
VCB is a type of circuit breaker that operates in a vacuum where the arc is drawn in a vacuum and extinguished using vacuum.
ACBs are commonly used in low voltage applications while VCBs are used in medium voltage applications.
...
I applied via Recruitment Consultant and was interviewed in Jun 2021. There was 1 interview round.
I have 10 years of work experience in mechanical engineering.
Designed and implemented mechanical systems for various projects
Performed analysis and simulations to optimize performance
Collaborated with cross-functional teams to ensure project success
Managed and supervised junior engineers
Implemented cost-saving measures in manufacturing processes
I applied via Naukri.com and was interviewed in May 2019. There were 3 interview rounds.
Worked as a Project Engineer at XYZ Company for 3 years.
Managed multiple projects simultaneously
Collaborated with cross-functional teams to ensure project success
Implemented cost-saving measures resulting in a 10% reduction in project expenses
based on 9 reviews
Rating in categories
Electrical Engineer
35
salaries
| ₹1.6 L/yr - ₹4.5 L/yr |
Facility Manager
25
salaries
| ₹4.6 L/yr - ₹9.7 L/yr |
Engineer
21
salaries
| ₹3 L/yr - ₹4.1 L/yr |
Senior Technician
16
salaries
| ₹1.2 L/yr - ₹3.2 L/yr |
Technician
16
salaries
| ₹2 L/yr - ₹2.9 L/yr |
Sodexo
ISS Facility Services
BVG India
Leadec India