The single line diagram of the plant I am working at shows the electrical connections and components in a simplified manner.
The single line diagram typically includes power sources, distribution lines, transformers, circuit breakers, and loads.
It provides a high-level overview of the electrical system without showing the physical location of each component.
Symbols are used to represent different electrical components a...
I was interviewed in Jan 2024.
Power factor is the ratio of real power to apparent power in an AC circuit. VFD stands for Variable Frequency Drive. AC motors run on alternating current while DC motors run on direct current.
Power factor is a measure of how effectively electrical power is being used in a circuit.
It is calculated by dividing the real power (in watts) by the apparent power (in volt-amperes).
A power factor of 1 indicates that all the pow...
Types of load cells include strain gauge load cells, hydraulic load cells, and capacitive load cells.
Strain gauge load cells measure the strain or deformation of a material.
Hydraulic load cells use hydraulic fluid to measure force.
Capacitive load cells measure changes in capacitance to determine force.
Other types of load cells include piezoelectric load cells and pneumatic load cells.
posted on 30 Nov 2023
I applied via Naukri.com and was interviewed in May 2023. There was 1 interview round.
Different types of protection are used in a substation to ensure safety and reliability.
Overcurrent protection: Protects against excessive current flow.
Overvoltage protection: Safeguards against high voltage surges.
Differential protection: Detects faults by comparing currents entering and leaving the substation.
Distance protection: Protects transmission lines based on the distance to the fault.
Ground fault protection: ...
Different types of HT breakers are used in HT lines depending on the specific requirements.
Air Circuit Breaker (ACB) is commonly used in HT lines for its high breaking capacity and quick response time.
Vacuum Circuit Breaker (VCB) is another popular choice due to its compact size and low maintenance requirements.
SF6 Circuit Breaker is used for high voltage applications as it provides excellent arc quenching properties.
O...
posted on 8 Feb 2022
posted on 3 Jun 2023
I applied via Referral and was interviewed before Jun 2022. There was 1 interview round.
posted on 30 Dec 2021
I applied via Shine and was interviewed in Dec 2021. There was 1 interview round.
A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction.
Transformers are used to increase or decrease the voltage of an alternating current (AC) signal.
They consist of two or more coils of wire, known as windings, that are wound around a core made of magnetic material.
The primary winding receives electrical energy from a power source, while t...
posted on 16 Nov 2021
based on 1 review
Rating in categories
Senior Engineer
48
salaries
| ₹3.4 L/yr - ₹7.9 L/yr |
Assistant Manager
44
salaries
| ₹3.3 L/yr - ₹10 L/yr |
Engineer
36
salaries
| ₹2 L/yr - ₹5.4 L/yr |
Manager
31
salaries
| ₹5.2 L/yr - ₹16.8 L/yr |
Assistant Engineer
24
salaries
| ₹1.4 L/yr - ₹5 L/yr |
JSW Steel
Tata Steel
Steel Authority Of India
Jindal Steel and Power