I applied via Company Website and was interviewed in May 2022. There were 3 interview rounds.
An Air Handling Unit (AHU) consists of several parts that work together to condition and circulate air.
Filter section: Removes dust and particles from the air.
Heating coil: Warms the air before it is distributed.
Cooling coil: Cools the air before it is distributed.
Humidifier: Adds moisture to the air if needed.
Fan: Circulates the air through the AHU.
Dampers: Control the flow of air.
Mixing chamber: Mixes outside and ret...
ACPH stands for Air Changes Per Hour.
ACPH is a measurement used to determine the rate at which the air in a space is replaced with fresh air.
It is commonly used in HVAC systems to ensure proper ventilation and air quality.
ACPH is calculated by dividing the volume of air in a space by the flow rate of fresh air into that space.
For example, if a room has a volume of 1000 cubic feet and fresh air is supplied at a rate of ...
The recommended ACPH for a kitchen depends on the size and type of kitchen.
The recommended ACPH for a commercial kitchen is 15-20 ACPH (air changes per hour).
The size and type of kitchen, as well as the type of cooking equipment used, can affect the recommended ACPH.
The ACPH can be calculated by dividing the volume of the kitchen by the airflow rate.
Proper ventilation and exhaust systems should be in place to maintain ...
VAV stands for Variable Air Volume.
VAV is a type of HVAC system that varies the airflow to different zones based on their heating and cooling needs.
It uses dampers to control the amount of air flowing into each zone.
VAV systems are energy-efficient and can save money on heating and cooling costs.
They are commonly used in commercial buildings and large residential buildings.
VAV systems can be controlled by a building au
VAV stands for Variable Air Volume. It is an HVAC system that controls the airflow to different zones based on their heating and cooling needs.
VAV uses a series of dampers to regulate the amount of air flowing into a space.
It measures the temperature of the air in each zone and adjusts the airflow accordingly.
VAV systems are energy-efficient as they only supply the amount of air required to maintain the desired tempera...
The thumb rule to calculate water consumption in a cooling tower is 3 GPM per every 100 tons of cooling.
Water consumption in cooling tower is calculated based on the cooling load
The thumb rule is 3 GPM per every 100 tons of cooling
Factors like temperature, humidity, and air flow rate affect water consumption
Water treatment and maintenance can also impact water consumption
Parameters considered while calculating heat load in a room
Size of the room
Number of occupants
Type and number of electrical appliances
Number and size of windows
Insulation of walls and ceiling
Orientation of the room
Climate of the region
Directions affect the amount of heat transferred and the efficiency of the system.
Heat transfer is affected by the direction of the flow of fluids or gases.
The orientation of the surface being heated or cooled affects the amount of heat transferred.
The direction of the sun's rays can affect the heat load on a building.
The direction of wind flow affects the heat load on a building.
Considering directions helps in designi
Top trending discussions
posted on 14 Oct 2022
I applied via Walk-in and was interviewed in Apr 2022. There were 2 interview rounds.
Auditing requirements refer to the standards and procedures that must be followed during an audit.
Auditing requirements ensure that audits are conducted in a consistent and thorough manner.
They include guidelines for planning, conducting, and reporting on audits.
Auditing requirements may be set by regulatory bodies, industry standards, or internal policies.
Examples of auditing requirements include the International Sta...
Welding electrode coding is used to identify the type of electrode and its characteristics.
The first two digits of the electrode coding indicate the minimum tensile strength of the weld metal in thousands of pounds per square inch (psi).
The third digit indicates the welding position(s) for which the electrode is suitable.
The fourth digit indicates the type of coating and the type of welding current (AC, DC, or both) th...
posted on 23 Dec 2024
I applied via Approached by Company and was interviewed in Nov 2024. There were 3 interview rounds.
MS stands for Mild Steel and SS stands for Stainless Steel.
MS (Mild Steel) is a type of carbon steel with low carbon content and is commonly used in construction.
SS (Stainless Steel) is a type of steel alloy with a minimum of 10.5% chromium content, known for its corrosion resistance.
SS is often used in kitchen appliances, surgical instruments, and industrial equipment.
MS is used in structural applications, automotive
posted on 24 Dec 2024
I was interviewed in Nov 2024.
Specification of machinery refers to the detailed requirements and characteristics of a machine or equipment.
Includes dimensions, materials, performance criteria, and safety features
Should be clearly defined to ensure proper design and functionality
Examples: maximum load capacity, operating temperature range, power consumption
posted on 3 Aug 2023
posted on 25 Apr 2024
I applied via Naukri.com and was interviewed in Oct 2023. There were 2 interview rounds.
posted on 28 Jun 2024
I applied via LinkedIn and was interviewed before Jun 2023. There was 1 interview round.
Fire NOC conditions refer to the requirements set by the fire department for ensuring fire safety in a building or establishment.
Fire NOC is required before starting any construction or occupancy of a building.
The building must comply with fire safety regulations such as having fire extinguishers, smoke detectors, and fire alarms installed.
Regular fire drills and training for occupants are necessary to ensure preparedn...
25 KV AC is more efficient for railways due to lower energy losses over long distances.
25 KV AC is more efficient for long distance transmission as it experiences lower energy losses compared to 750V DC.
25 KV AC allows for higher speeds and heavier loads on the railway system.
25 KV AC is the standard voltage used in many modern railway systems around the world, such as in Europe and parts of Asia.
750V DC may be more su...
Reverse a string without using string or inbuilt function
Create an array of characters to store the string
Use two pointers, one at the beginning and one at the end, swap characters until they meet
Repeat until all characters are swapped
posted on 16 May 2023
I applied via Naukri.com and was interviewed in Jan 2023. There were 2 interview rounds.
Associate Manager
294
salaries
| ₹5.1 L/yr - ₹18.8 L/yr |
Junior Manager
240
salaries
| ₹3.5 L/yr - ₹12 L/yr |
Manager
122
salaries
| ₹8.1 L/yr - ₹28 L/yr |
Senior Engineer
114
salaries
| ₹3.6 L/yr - ₹8.5 L/yr |
Executive Accountant
56
salaries
| ₹3 L/yr - ₹7.5 L/yr |
Adani Group
Tata Group
Reliance Industries
Essar Group